Real-time measurements of coagulation on bacterial cellulose and conventional vascular graft materials
Source abstract
Abstract
The search for a functional, small diameter (<5mm) vascular graft has been ongoing for over 30 years, but yet there is no consistently reliable synthetic graft. The primary mechanisms of graft failure are intimal hyperplasia, poor blood flow and surface thrombogenicity. Bacterial cellulose (BC) became therefore a proposed new biosynthetic vascular graft material. Since conventional methods are not suited for coagulation measurements on BC, we have adapted the automated calibrated thrombin generation method for measurements of biomaterial-induced coagulation of BC as compared with clinically used graft materials i.e., expanded poly(tetrafluoroethylene) (ePTFE) and poly(ethyleneterephtalat) (PET). We have also visualized the coagulation propagation at the material surfaces. Thrombin generation experiments revealed dramatic differences between the materials tested. Both ePTFE and BC were found to generate longer lag times and ttpeak values than PET. Most importantly, BC was found to generate the lowest "peak", indicating a slower coagulation process at the surface. These results are also supported by the measurements of factor XIIa generation and analysis of surface coagulation times, which were detected in the following increasing order (mean + or - SD): PET (27 + or - 8 min)<BC (46 + or - 9 min)<ePTFE (61 + or - 21 min). Real-time measurement of coagulation seems to have the potential for becoming a powerful tool for evaluation of biomaterials for blood-contacting devices.
Source: europepmc · Quality: candidate unverified · Source record ↗
Research context
OpenAlex topics: Electrospun Nanofibers in Biomedical Applications · Hemostasis and retained surgical items · Polymer Surface Interaction Studies
SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.
References (36)
Show source-provided references
1. Endothelial sodding of the Permaflow prosthetic coronary artery bypass conduit10.1016/S0003-4975(98)00780-2 ↗
2. Biocompatibility of sulphonated polyurethane surfaces10.1016/0142-9612(96)00005-1 ↗
3. Rapid activation of the complement system by cuprophane depends on complement component C410.1111/j.1523-1755.1998.00836.x ↗
4. Clinical characterization of Dicea a new cellulose membrane for haemodialysis
5. Synthetically modified cellulose: an alternative to synthetic membranes for use in haemodialysis?10.1016/S0142-9612(97)00062-8 ↗
6. Polymers
7. A review of the biostability and carcinogenicity of polyurethanes in medicine and the new generation of ‘biostable’ polyurethanes10.1163/156856294X00347 ↗
8. First clinical use of the Possis synthetic coronary graft10.1111/j.1540-8191.1993.tb00391.x ↗
9. Polytetrafluoroethylene graft for spontaneous coronary dissection: 7-year follow-up10.1016/0003-4975(90)90214-Q ↗
10. Improving the patency of vascular bypass grafts: the role of suture materials and surgical techniques on reducing anastomotic compliance mismatch10.1053/ejvs.2002.1810 ↗
11. Bacterial cellulose as scaffold for tissue engineering
12. In vivo biocompatibility of bacterial cellulose10.1002/jbm.a.30570 ↗
13. Mechanical properties of bacterial cellulose and interactions with smooth muscle cells10.1016/j.biomaterials.2005.10.026 ↗
14. Methods of investigating protein interactions on artificial and natural surfaces10.1111/j.1749-6632.1987.tb33050.x ↗
15. Ellipsometer recordings of changes in optical thickness of adsorbed films associated with surface activation of blood clotting10.1038/204701b0 ↗
16. Identification of rapid changes at plasma–solid interfaces10.1002/jbm.820030106 ↗
17. Perspectives on blood/materials interactions10.1002/jbm.a.10480 ↗
18. Mechanism of transient adsorption of fibrinogen from plasma to solid surfaces: role of the contact and fibrinolytic systems10.1182/blood.V71.4.932.932 ↗
19. Surface plasmon resonance and free oscillation rheometry in combination: a useful approach for studies on haemostasis and interactions between whole blood and artificial surfaces10.1016/S0956-5663(02)00048-9 ↗
20. Quartz crystal microbalance-with dissipation monitoring (QCM-D) for real time measurements of blood coagulation density and immune complement activation on artificial surfaces10.1016/j.bios.2004.09.026 ↗
21. Acoustics of blood plasma on solid surfaces10.1163/156856202320401951 ↗
22. The effect of substrate molecular mobility on surface induced immune complement activation and blood plasma coagulation10.1016/j.biomaterials.2003.11.050 ↗
23. Methods for research on immune complement activation on modified sensor surfaces10.1016/S0927-7765(02)00066-8 ↗
24. Immune complement activation on polystyrene and silicon dioxide surfaces Impact of reversible IgG adsorption10.1016/j.molimm.2004.09.015 ↗
25. Towards a standardization of thrombin generation assessment: the influence of tissue factor, platelets and phospholipids concentration on the normal values of thrombogram–thrombinoscope assay10.1186/1477-9560-3-16 ↗
26. Calibrated automated thrombin generation measurement in clotting plasma10.1159/000071636 ↗
27. Coagulation and complement activation10.1016/S0142-9612(00)00190-3 ↗
28. Coagulation, fibrinolysis, and cell activation in patients and shed mediastinal blood during coronary artery bypass grafting with a new heparin-coated surface10.1067/mtc.2002.122551 ↗
29. Imaging of blood plasma coagulation and its propagation at surfaces10.1002/jbm.a.31529 ↗
30. Evaluation of the thrombogenic potential of three types of arterial graft studied in an artificial circulation10.1002/bjs.1800650416 ↗
31. Study on hydrophilicity of polymer surfaces improved by plasma treatment10.1016/j.apsusc.2005.05.038 ↗
32. Contributions of contact activation pathways of coagulation factor XII in plasma
33. Autoactivation of blood factor XII at hydrophilic and hydrophobic surfaces10.1016/j.biomaterials.2006.04.001 ↗
34. Competitive-protein adsorption in contact activation of blood factor XII10.1016/j.biomaterials.2007.06.019 ↗
35. Hydrostatic pressure reduces thrombogenicity of polytetrafluoroethylene vascular grafts
36. Comparison of coagulation activity tests in vitro for selected biomaterials10.1046/j.1525-1594.2002.06872.x ↗