journal article·2013-09

Three-dimensional quantification of susceptibility artifacts from various metals in magnetic resonance images

Haruki Imai, Yoji Tanaka, Naoyuki Nomura, Yusuke Tsutsumi, Hisashi Doi, Zuisei Kanno, Kikuo Ohno, Takashi Ono, Takao Hanawa

Acta Biomaterialia· Volume 9· Issue 9
Publisher page

Abstract

Susceptibility artifacts generated in magnetic resonance (MR) images were quantitatively evaluated for various metals using a three-dimensional (3-D) artifact rendering to demonstrate the correlation between magnetic susceptibility and artifact volume. Ten metals (stainless steel, Co-Cr alloy, Nb, Ti, Zr, Mo, Al, Sn, Cu and Ag) were prepared, and their magnetic susceptibilities measured using a magnetic balance. Each metal was embedded in a Ni-doped agarose gel phantom and the MR images of the metal-containing phantoms were taken using 1.5 and 3.0 T MR scanners under both fast spin echo and gradient echo conditions. 3-D renderings of the artifacts were constructed from the images and the artifact volumes were calculated for each metal. The artifact volumes of metals decreased with decreasing magnetic susceptibility, with the exception of Ag. Although Sn possesses the lowest absolute magnetic susceptibility (1.8×10(-6)), the artifact volume from Cu (-7.8×10(-6)) was smaller than that of Sn. This is because the magnetic susceptibility of Cu was close to that of the agarose gel phantom (-7.3×10(-6)). Since the difference in magnetic susceptibility between the agarose and Sn is close to that between the agarose and Ag (-17.5×10(-6)), their artifact volumes were almost the same, although they formed artifacts that were reversed in all three dimensions.
Source: europepmc · Quality: candidate unverified · Source record ↗

Research context

OpenAlex topics: Advanced MRI Techniques and Applications · MRI in cancer diagnosis · Advanced X-ray and CT Imaging

SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.

References (30)

Show source-provided references
1. Magnetic resonance imaging artifacts caused by aneurysm clips and shunt valves: dependence on field strength (1.5T and 3T) and imaging parameters10.1002/jmri.20391 ↗
2. MR imaging of vascular stents: effects of susceptibility, flow, and radiofrequency eddy currents10.1016/S1051-0443(07)61918-6 ↗
3. Magnetic resonance imaging diagnosis of the temporomandibular joint in patients with orthodontic appliances10.1067/moe.2003.37 ↗
4. Influence of common orthodontic appliances on the diagnostic quality of cranial magnetic resonance images10.1016/j.ajodo.2006.10.038 ↗
5. Artifacts in brain magnetic resonance imaging due to metallic dental objects
6. Metallic artifact in MRI after removal of orthopedic implants10.1016/j.ejrad.2010.11.014 ↗
7. A comparison of magnetic and radiographic imaging artifact after using three types of metal rods: stainless steel, titanium, and vitallium10.1016/j.spinee.2010.06.006 ↗
8. Overcoming artifacts from metallic orthopedic implants at high-field-strength MR imaging and multidetector CT10.1148/rg.273065087 ↗
9. Managing postoperative artifacts on computed tomography and magnetic resonance imaging10.1055/s-0031-1286013 ↗
10. Metal-related artifacts in instrumented spine. Techniques for reducing artifacts in CT and MRI: state of the art10.1007/s00586-009-0998-5 ↗
11. Quantification and minimization of magnetic susceptibility artifacts on GRE images10.1097/00004728-200011000-00024 ↗
12. Metallic artefacts in MR imaging: effects of main field orientation and strength10.1016/S0009-9260(02)00540-8 ↗
13. Magnetic susceptibility artifacts on high-resolution MR of the temporal bone
14. Magnetic resonance spectroscopic imaging for visualization and correction of distortions in MRI: high precision applications in neurosurgery10.1016/S0730-725X(98)00095-2 ↗
15. Correction of MR image distortions induced by metallic objects using a 3-D cubic B-spline basis set: application to stereotactic surgical planning10.1002/mrm.20528 ↗
16. Improving geometric accuracy in the presence of susceptibility difference artifacts produced by metallic implants in magnetic resonance imaging10.1109/TMI.2005.857230 ↗
17. Characterization, prediction, and correction of geometric distortion in 3T MR images10.1118/1.2402331 ↗
18. Numerical determination of the susceptibility caused geometric distortions in magnetic resonance imaging10.1016/S1361-8415(02)00109-3 ↗
19. Integral method for numerical simulation of MRI artifacts induced by metallic implants10.1002/mrm.1098 ↗
20. The role of magnetic susceptibility in magnetic resonance imaging: MRI magnetic compatibility of the first and second kinds10.1118/1.597854 ↗
21. Artifacts from dental casting alloys in magnetic resonance imaging10.1177/154405910308200806 ↗
22. Quantitative analysis of magnetic resonance imaging susceptibility artifacts caused by neurosurgical biomaterials: comparison of 0.5, 1.5, and 3.0T magnetic fields10.2176/nmc.45.395 ↗
23. Effects of phase construction of Zr-Nb alloys on their magnetic susceptibilities10.2320/matertrans.M2009187 ↗
24. Microstructure and mechanical properties of as-cast Zr-Nb alloys10.1016/j.actbio.2011.07.020 ↗
25. Microstructure and mechanical properties of as-cast Zr-Nb alloys10.1016/j.actbio.2011.07.020 ↗
26. Effects of phase constitution on magnetic susceptibility and mechanical properties of Zr-rich Zr-Mo alloys10.1016/j.actbio.2011.07.005 ↗
27. Nickel-doped agarose gel phantoms in MR imaging10.1177/028418519103200519 ↗
28. Standard test method for evaluation of MR image artifacts from passive implants. ASTM designation: F2119–01 2001; doi:http://dx.doi.org/10.1520/F2119-01.10.1520/F2119-01 ↗
29. Lide · 2006
30. Magnetic resonance imaging measurement of volume magnetic susceptibility using a boundary condition10.1006/jmre.1999.1873 ↗