A closer look at the in vitro electrochemical characterisation of titanium alloys for biomedical applications using in-situ methods
Source abstract
Abstract
Titanium (Ti) and its alloys are widely used in several biomedical applications, particularly as permanent orthopaedic implants. Electrochemical testing provides a means to perform accelerated corrosion testing, however whilst results from polarisation testing for Ti and its alloys to date have been generally useful, they are also rather limited on the basis of several reasons. One reason is that the polarisation curves for Ti and its alloys in simulated body fluids all appear rather similar, and they do not present a classical 'breakdown' or pitting potential, making discrimination between alloys difficult. Of practical relevance however, are two key issues; (1) how do Ti alloys respond to a breakdown event? (i.e. do they readily 'repassivate'?), and, (2) what is that actual rate of Ti ion loss from exposure to physiological conditions? The answers to these questions are probed herein. Several Ti alloys of either unique composition or different fabrication method were studied, including commercially pure Ti (cp-Ti), Ti-6Al-4V, Ti-29Nb-13Ta-4.5Zr (TNTZ), selective laser melted Ti-6Al-4V, direct laser deposited cp-Ti, Ti-35Nb-15Zr, and Ti-25Nb-8Zr. Results reveal that both fabrication method and alloying influence 'repassivation' behaviour. Furthermore, atomic emission spectroelectrochemistry as applied to cp-Ti indicated actual dissolution currents of ∼2-3μA/cm-2 (i.e. ∼9μm/yr) in the range of the corrosion potential, also revealing such dissolution is persistent, even with cathodic polarisation, and definitively revealing that the presence of hydrogen peroxide and albumin activate anodic dissolution of Ti. Statement of significance We believe the paper makes a significant and important contribution to the field of permanent implant biomaterials. Whilst we concede that the paper does not include any in vivo work, the timeliness of the work, and the completely new nature of the findings, we believe carries the impact required for Acta Biomaterialia. Key highlights include:All of the above combine to produce a manuscript that we believe has wide appeal, and can be used as both a port of reference to those working with Ti biomaterials, and also those wishing to apply useful characterisation techniques to their own work (with two very novel methods demonstrated herein, along with the unique information they provide).
Source: europepmc · Quality: candidate unverified · Source record ↗
Research context
OpenAlex topics: Titanium Alloys Microstructure and Properties · Orthopaedic implants and arthroplasty · Hydrogen embrittlement and corrosion behaviors in metals
SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.
References (45)
Show source-provided references
1. Implant-delivered alendronate causes a dose-dependent response on net bone formation around porous titanium implants in canines10.1007/s11999-016-4714-6 ↗
2. Ti based biomaterials, the ultimate choice for orthopaedic implants – A review10.1016/j.pmatsci.2008.06.004 ↗
3. Development of new metallic alloys for biomedical applications10.1016/j.actbio.2012.06.037 ↗
4. Ti based biomaterials, the ultimate choice for orthopaedic implants–a review10.1016/j.pmatsci.2008.06.004 ↗
5. Mechanical properties of biomedical titanium alloys10.1016/S0921-5093(97)00806-X ↗
6. Fracture mechanisms of retrieved titanium screw thread in dental implant10.1016/S0142-9612(01)00380-5 ↗
7. Current concepts review-corrosion of metal orthopaedic implants10.2106/00004623-199802000-00015 ↗
8. Influence of potential on the electrochemical behaviour of β titanium alloys in Hank’s solution10.1016/j.actbio.2007.02.009 ↗
9. Corrosion characterization of titanium alloys by electrochemical techniques10.1016/j.electacta.2005.02.121 ↗
10. Electrochemical stability and corrosion resistance of Ti–Mo alloys for biomedical applications10.1016/j.actbio.2008.07.010 ↗
11. Corrosion behaviour and biocompatibility of boron containing titanium alloys in simulated physiological environments10.1179/1743278212Y.0000000035 ↗
12. The environmental stability of boron-containing titanium alloys for biomedical applications10.1007/s11837-011-0091-5 ↗
13. Corrosion resistance and in vitro response of laser-deposited Ti-Nb-Zr-Ta alloys for orthopedic implant applications10.1002/jbm.a.32782 ↗
14. Corrosion behavior and surface characterization of titanium in solution containing fluoride and albumin10.1016/j.biomaterials.2004.03.025 ↗
15. Quantitative and temporal characterization of the extracellular H2O2 pool generated by human neutrophils10.1016/S0021-9258(17)43674-X ↗
16. Hydrogen peroxide as a potent bacteriostatic antibiotic: implications for host defense10.1016/0891-5849(95)00005-I ↗
17. A synergistic effect of albumin and H2O2 accelerates corrosion of Ti6Al4V10.1016/j.actbio.2015.07.046 ↗
18. A study of the potentials achieved during mechanical abrasion and the repassivation rate of titanium and Ti6Al4V in inorganic buffer solutions and bovine serum10.1016/j.electacta.2004.07.024 ↗
19. J.L. Gilbert, C.A. Buckley, E.P. Lautenschlager, Titanium oxide film fracture and repassivation: the effect of potential, pH and aeration, in: Medical applications of titanium and its alloys: The material and biological issues, ASTM International, 1996
20. Repassivation behavior of titanium in artificial saliva investigated with a photon rupture method10.1016/j.electacta.2010.08.090 ↗
21. Osteoanabolic implant materials for orthopedic treatment10.1002/adhm.201600074 ↗
22. Titanium based metal-matrix composites via in-situ nitridation
23. Laser deposition and deformation behavior of Ti-Nb-Zr-Ta alloys for orthopedic implants10.1016/j.jmbbm.2012.08.014 ↗
24. Mg dissolution in phosphate and chloride electrolytes: Insight into the mechanism of the negative difference effect10.5006/1459 ↗
25. A novel approach to on-line measurement of gas evolution kinetics: Application to the negative difference effect of Mg in chloride solution10.1016/j.electacta.2013.07.131 ↗
26. Atomic emission spectroelectrochemistry: A new look at the corrosion, dissolution and passivation of complex materials
27. The cathodic dissolution of Al, Al2Cu, and Al alloys10.1016/j.electacta.2010.09.058 ↗
28. The anodic dissolution of Mg in NaCl and Na2SO4 electrolytes by atomic emission spectroelectrochemistry10.1016/j.corsci.2010.02.038 ↗
29. Atomic emission spectroelectrochemistry applied to dealloying phenomena: I. The formation and dissolution of residual copper films on stainless steel10.1016/j.electacta.2009.01.037 ↗
30. Investigating the Passivity and Dissolution of a Corrosion Resistant Mg-33at. %Li Alloy in Aqueous Chloride Using Online ICP-MS10.1149/2.0871606jes ↗
31. Stochastic models of pitting corrosion of stainless steels I. Modeling of the initiation and growth of pits at constant potential10.1149/1.2114220 ↗
32. Barsoukov · 2005
33. Use of the time constant to detect corrosion speed in reinforced concrete structures10.1016/j.cemconcomp.2006.12.007 ↗
34. Electrochemical corrosion of titanium and titanium-based alloys10.1067/mpr.2001.113029 ↗
35. Corrosion and passivity of Ti-13% Nb-13% Zr in comparison to other biomedical implant alloys10.5006/1.3290281 ↗
36. The effect of temperature on the nucleation of corrosion pits on titanium in Ringer’s physiological solution10.1016/j.biomaterials.2004.02.023 ↗
37. A study of the microstructural evolution during selective laser melting of Ti–6Al–4V10.1016/j.actamat.2010.02.004 ↗
38. Direct laser deposition of in situ Ti–6Al–4V–TiB composites10.1016/S0921-5093(03)00299-5 ↗
39. Titanium alloys for biomedical applications10.1016/j.msec.2005.08.032 ↗
40. Microstructural evolution in laser deposited compositionally graded α/β titanium-vanadium alloys10.1016/S1359-6454(03)00158-7 ↗
41. Electrochemical studies on the stability and corrosion resistance of titanium-based implant materials10.1016/S0142-9612(00)00309-4 ↗
42. 2014
43. 2015
44. Influence of fluoride, hydrogen peroxide and lactic acid on the corrosion resistance of commercially pure titanium10.1016/j.actbio.2005.09.004 ↗
45. Hydrogen peroxide toward enhanced oxide growth on titanium in PBS solution: blue coloration and clinical relevance10.1002/(SICI)1097-4636(199603)30:3<393::AID-JBM14>3.0.CO;2-L ↗