This paper reports on the effects of porosity and its distribution on the fatigue strength of bone cement. Hand-mixed (HM) and vacuum-mixed (VM) bone cement samples were fatigue tested to failure. The point of failure commonly coincided with large single pores (in the VM materials) and multiple pores in clusters (in the HM material). The effect of pores was analysed using the Theory of Critical Distances (TCD), a theory previously developed to explain the effect of notches and other stress concentrations on fatigue and fracture. Clusters of pores were analysed by developing a criterion to decide whether local cracking would act to link pores together, forming a single stress concentration of more complex shape. This approach enabled us to predict the high-cycle fatigue strength of samples containing clusters of pores, with good accuracy (errors less than 13%). We then used the analysis to develop general rules for the effect of pore size and proximity on fatigue strength. For example, we showed that a single pore of 2mm diameter or more would cause a significant decrease in the fatigue strength (compared to that of pore-free material); however, two pores of only 1mm diameter in close proximity would be equally damaging. This demonstrates the importance not only of pore size but also of pore density and distribution. However, pores do have beneficial effects such as improved drug dispersion, bone ingrowth and crack tip blunting. Therefore, given the findings from this study, a possible step forward in the development of surgical bone cements may involve a compromise in which relatively small pores are evenly distributed throughout the material.
Source: europepmc · Quality: candidate unverified · Source record ↗

Research context

OpenAlex topics: Orthopaedic implants and arthroplasty · Bone Tissue Engineering Materials · Total Knee Arthroplasty Outcomes

SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.

References (32)

Show source-provided references
1. Properties of acrylic bone cement: state of the art review10.1002/(SICI)1097-4636(199722)38:2<155::AID-JBM10>3.0.CO;2-C ↗
2. Karrholm · Swed Hip Arthropl Reg · 2005
3. Economics of revision total hip arthroplasty10.1016/j.cuor.2006.02.007 ↗
4. The Danish hip arthroplasty register10.1080/000164700317381081 ↗
5. The Norwegian arthroplasty register – 11 years and 73,000 arthroplasties10.1080/000164700317393321 ↗
6. The initiation of failure in cemented femoral components of hip arthroplasties10.1302/0301-620X.73B4.2071634 ↗
7. A fractographic analysis of in vivo poly(methyl methacrylate) bone cement failure mechanisms10.1002/jbm.820240202 ↗
8. Fatigue in porous PMMA: the effect of stress concentrations10.1016/j.ijfatigue.2007.08.022 ↗
9. Fatigue failure in the cement mantle of an artificial hip joint10.1016/0267-6605(93)90056-D ↗
10. Assessment of cement introduction and pressurization techniques10.1243/095441104322807712 ↗
11. A theoretical and experimental analysis of polymerization shrinkage of bone cement: a potential major source of porosity10.1002/1097-4636(200010)52:1<210::AID-JBM27>3.0.CO;2-R ↗
12. On fatigue lifetimes and fatigue crack growth behaviour of bone cement10.1023/A:1008978302196 ↗
13. A methodology and criterion for acrylic bone cement fatigue tests10.1046/j.1460-2695.2000.00327.x ↗
14. Microdamage accumulation in the cement layer of hip replacements under flexural loading10.1016/S0021-9290(99)00018-4 ↗
15. The relationship between porosity and fatigue characteristics of bone cements10.1016/S0142-9612(02)00296-X ↗
16. On the magnitude and variability of the fatigue strength of bone cement10.1016/S0142-1123(00)00055-4 ↗
17. A fractographic investigation of PMMA bone cement focusing on the relationship between porosity reduction and increased fatigue life10.1002/jbm.820260507 ↗
18. On the importance of considering porosity when simulating the fatigue of bone cement10.1115/1.1934182 ↗
19. Porosity reduction in acrylic cement is clinically irrelevant10.1097/00003086-199810000-00026 ↗
20. The clinical significance of vacuum mixing bone cement10.1097/00003086-200101000-00034 ↗
21. Why would cement porosity reduction be clinically irrelevant, while experimental data show the contrary10.1016/j.orthres.2004.12.002 ↗
22. Mechanical performance of acrylic bone cements containing different radiopacifying agents10.1016/S0142-9612(01)00314-3 ↗
23. Vacuum-mixing cement does not decrease overall porosity in cemented femoral stems10.1302/0301-620X.89B8.19129 ↗
24. Surface roughness, porosity and wettability of gentamicin-loaded bone cements and their antibiotic release10.1016/S0142-9612(00)00082-X ↗
25. Porosity of 3-D biomaterial scaffolds and osteogenesis10.1016/j.biomaterials.2005.02.002 ↗
26. Microstructural pathway of fracture in poly(methyl methacrylate) bone cement10.1016/0142-9612(93)90162-U ↗
27. The effect of stress concentrations on the fracture strength of polymethylmethacrylate10.1016/j.msea.2004.05.012 ↗
28. Taylor · 2007
29. Static and fatigue mechanical behavior of bone cement with elevated barium sulphate content for treatment of vertebral compression fractures10.1016/j.biomaterials.2004.09.055 ↗
30. Effects of porosity on the fatigue performance of polymethyl methacrylate bone cement: an analytical investigation10.1177/095441000622000101 ↗
31. Release of gentamicin from acrylic bone cement. Elution and diffusion studies10.2106/00004623-198870100-00015 ↗
32. Porous polymethylmethacrylate as bone substitute in the craniofacial area10.1097/00001665-200307000-00035 ↗