journal article·2020-03Open access

Exploring polyoxometalates as non-destructive staining agents for contrast-enhanced microfocus computed tomography of biological tissues

Sébastien de Bournonville, Sarah Vangrunderbeeck, Hong Giang T. Ly, Carla Geeroms, Wim M. De Borggraeve, Tatjana N. Parac-Vogt, Greet Kerckhofs

Acta Biomaterialia· Volume 105

Abstract

To advance clinical translation of regenerative medicine, there is, amongst others, still need for better insights in tissue development and disease. For this purpose, more precise imaging of the 3D microstructure and spatial interrelationships of the different tissues within organs is crucial. Despite being destructive towards the sample, conventional histology still is the gold standard for structural analysis of biological tissues. It is, however, limited by 2D sections of a 3D object, prohibiting full 3D structural analysis. MicroCT has proven to provide full 3D structural information of mineralized tissues and dense biomaterials. However, the intrinsic low X-ray absorption of soft tissues requires contrast-enhancing staining agents (CESAs). In a previous study, we showed that hafnium-substituted Wells-Dawson polyoxometalate (Hf-WD POM) allows simultaneous contrast-enhanced microCT (CE-CT) visualization of bone and its marrow vascularization and adiposity. In this study, other POM species have been examined for their potential as soft tissue CESAs. Four Wells-Dawson POMs, differing in structure and overall charge, were used to stain murine long bones and kidneys. Their staining potential and diffusion rate were compared to those of Hf-WD POM and phosphotungstic acid (PTA), a frequently used but destructive CESA. Monolacunary Wells-Dawson POM (Mono-WD POM) showed similar soft tissue enhancement as Hf-WD POM and PTA. Moreover, Mono-WD POM is less destructive, shows a better diffusion than PTA, and its synthesis requires less time and cost than Hf-WD POM. Finally, the solubility of Mono-WD POM was improved by addition of lithium chloride (LiCl) to the staining solution, enhancing further the soft tissue contrast. STATEMENT OF SIGNIFICANCE: To advance clinical translation of regenerative medicine, there is, amongst others, still need for better insights in tissue development and disease. For this purpose, more precise imaging of the 3D microstructure and spatial interrelationships of the different tissues within organs is crucial. Current standard structural analysis techniques (e.g. 2D histomorphometry), however, do not allow full 3D assessment. Contrast-enhanced X-ray computed tomography has emerged as a powerful 3D structural characterization tool of soft biological tissues. In this study, from a library of Wells Dawson polyoxometalates (WD POMs), we identified monolacunary WD POM together with lithium chloride, dissolved in phosphate buffered saline, as the most suitable contrast-enhancing staining agent solution for different biological tissues without tissue shrinkage.
Source: europepmc · Quality: candidate unverified · Source record ↗

Research context

OpenAlex topics: Bone Tissue Engineering Materials · Cerebrovascular and Carotid Artery Diseases · Bone Metabolism and Diseases

SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.

References (48)

Show source-provided references
1. Microcomputed tomography-based structural analysis of various bone tissue regeneration models10.1038/nprot.2010.180 ↗
2. Guidelines for assessment of bone microstructure in rodents using micro-computed tomography10.1002/jbmr.141 ↗
3. Combining microCT-based characterization with empirical modelling as a robust screening approach for the design of optimized cap-containing scaffolds for progenitor cell-mediated bone formation10.1016/j.actbio.2016.02.037 ↗
4. Nanoparticle contrast agents for computed tomography: a focus on micelles10.1002/cmmi.1551 ↗
5. X-ray-computed tomography contrast agents10.1021/cr200358s ↗
6. Multifactorial optimization of contrast-enhanced nanofocus computed tomography for quantitative analysis of neo-tissue formation in tissue engineering constructs10.1371/journal.pone.0130227 ↗
7. Nondestructive assessment of sGAG content and distribution in normal and degraded rat articular cartilage via EPIC-mu CT10.1016/j.joca.2009.07.014 ↗
8. Cationic agent contrast-enhanced computed tomography imaging of cartilage correlates with the compressive modulus and coefficient of friction10.1016/j.joca.2012.09.007 ↗
9. Bath concentration of anionic contrast agents does not affect their diffusion and distribution in articular cartilage in vitro10.1177/1947603512451023 ↗
10. Contrast-enhanced nanofocus X-Ray computed tomography allows virtual three-dimensional histopathology and morphometric analysis of osteoarthritis in small animal models10.1177/1947603513501175 ↗
11. Contrast-enhanced CT with a high-affinity cationic contrast agent for imaging ex vivo bovine, intact ex vivo rabbit, and in vivo rabbit cartilage10.1148/radiol.12112246 ↗
12. Assessment of contrast-enhanced computed tomography for imaging of cartilage during fracture healing10.1002/jor.22265 ↗
13. Effects of articular cartilage constituents on phosphotungstic acid enhanced micro-computed tomography10.1371/journal.pone.0171075 ↗
14. 3D histopathological grading of osteochondral tissue using contrast-enhanced micro-computed tomography10.1016/j.joca.2017.05.021 ↗
15. Determining collagen distribution in articular cartilage using contrast-enhanced micro-computed tomography10.1016/j.joca.2015.05.004 ↗
16. Bone marrow fat accumulation accelerated by high fat diet is suppressed by exercise10.1016/j.bone.2014.03.044 ↗
17. Region-specific variation in the properties of skeletal adipocytes reveals regulated and constitutive marrow adipose tissues10.1038/ncomms8808 ↗
18. Use of osmium tetroxide staining with microcomputerized tomography to visualize and quantify bone marrow adipose tissue in vivo10.1016/B978-0-12-411619-1.00007-0 ↗
19. MicroCT for comparative morphology: simple staining methods allow high-contrast 3D imaging of diverse non-mineralized animal tissues10.1186/1472-6793-9-11 ↗
20. A novel 3D mouse embryo atlas based on micro-CT10.1242/dev.082016 ↗
21. X-ray-Computed tomography contrast agents10.1021/cr200358s ↗
22. Evaluation of X-ray tomography contrast agents: a review of production, protocols, and biological applications10.1002/jemt.23225 ↗
23. Contrast-enhanced microCT for virtual 3D anatomical pathology of biological tissues: a literature review10.1155/2019/8617406 ↗
24. Concentration-dependent specimen shrinkage in iodine-enhanced microCT10.1111/joa.12068 ↗
25. Volume shrinkage of bone, brain and muscle tissue in sample preparation for micro-CT and light sheet fluorescence microscopy (LSFM), microscopy and microanalysis : the official journal of microscopy society of america, microbeam analysis society
26. Sensory epithelia of the fish inner ear in 3D: studied with high-resolution contrast enhanced microCT10.1186/1742-9994-10-63 ↗
27. An exploratory study of contrast agents for soft tissue visualization by means of high resolution X-ray computed tomography imaging10.1111/jmi.12013 ↗
28. Simultaneous three-dimensional visualization of mineralized and soft skeletal tissues by a novel microCT contrast agent with polyoxometalate structure10.1016/j.biomaterials.2017.12.016 ↗
29. Acidity measurements on a heteropolyacid hydrate in acetic-acid solution - a case of 3 hydrons ionizing independently, rather than consecutively10.1006/jcat.1995.1073 ↗
30. Syntheses and X-ray crystal structures of zirconium(IV) and hafnium(IV) complexes containing monovacant wells-Dawson and Keggin polyoxotungstates10.1021/ic060656e ↗
31. Ginsberg · 199010.1002/9780470132586 ↗
32. Changes in bone macro- and microstructure in diabetic obese mice revealed by high resolution microfocus X-ray computed tomography10.1038/srep35517 ↗
33. Volume shrinkage of bone, brain and muscle tissue in sample preparation for micro-CT and light sheet fluorescence microscopy (LSFM)10.1017/S1431927614001329 ↗
34. Effects of counterions in heteropoly electrolyte chemistry. 1. Evaluations of relative interactions by NMR on Kozik salts10.1021/ic971382l ↗
35. Formation of 1 : 1 and 2 : 2 complexes of Ce(III) with the heteropolytungstate anion alpha(2)- P2W17O61 (10-), and their interaction with proline. The structure of Ce-2(P2W17O61)(2)(H2O)(8) (14-)10.1039/b105967j ↗
36. Rapid 3D phenotyping of cardiovascular development in mouse embryos by micro-ct with iodine staining10.1161/CIRCIMAGING.109.918482 ↗
37. Concentration-dependent specimen shrinkage in iodine-enhanced microCT10.1111/joa.12068 ↗
38. M.J. West, Tissue Shrinkage and Stereological Studies, Cold Spring Harbor Protocols2013(3) (2013) pdb.top071860.10.1101/pdb.top071860 ↗
39. 2017 · 113
40. Peptide bond hydrolysis catalyzed by the Wells-Dawson Zr(alpha2-P2W17O61)2 polyoxometalate10.1021/ic301364n ↗
41. Amide bond hydrolysis in peptides and cyclic peptides catalyzed by a dimeric Zr(IV)-substituted Keggin type polyoxometalate10.1039/c3dt50705j ↗
42. Sensing the chirality of Dawson lanthanide polyoxometalates [alpha1-LnP2W17O61]7- by multinuclear NMR spectroscopy10.1002/chem.200701429 ↗
43. Chemoselective catalysis with organosoluble Lewis acidic polyoxotungstates10.1002/chem.201000411 ↗
44. Quantitative determination of aqueous dodecatungstophosphoric acid speciation by NMR spectroscopy10.1071/CH02037 ↗
45. A study of the decomposition behaviour of 12-tungstophosphate heteropolyacid in solution10.1139/v03-129 ↗
46. Complexes of Zr-IV and Hf-IV with monolacunary Keggin- and Dawson-type anions10.1007/s11172-007-0036-x ↗
47. Lyon · J. Am. Chem. Soc. · 1991 · 113 · 720910.1021/ja00019a018 ↗
48. Intracellular pH measurements by P-31 nuclear magnetic-resonance influence of factors other than ph on P-31 chemical-shifts10.1021/bi00522a006 ↗