First insight on the impact of an osteoblastic layer on the bio-tribocorrosion performance of Ti6Al4V hip implants
Source abstract
Abstract
In uncemented Ti6Al4V hip implants, the bone-stem interface is subjected to cyclic loading motion driven by the daily activities of the patients, which may lead to the complete failure of the implant in the long term. It may also compromise the proliferation and differentiation processes of osteoblastic cells (bone-forming cells). The main objective of this work is to approach for the first time the role of these organic materials on the bio-tribocorrosion mechanisms of cultured Ti6Al4V alloys. The colonized materials with MG63 osteoblastic-like cells were characterized through cell viability/proliferation and enzymatic activity. Tribocorrosion tests were performed under a reciprocating sliding configuration and low contact pressure. Electrochemical techniques were used to measure the corrosion kinetics of the system, under free potential conditions. All tests were performed at a controlled atmosphere. The morphology and topography of the wear scar were evaluated. The results showed that the presence of an osteoblastic cell layer on the implant surface significantly influences the tribocorrosion behavior of Ti6Al4V alloy. It was concluded that the cellular material was able to form an extra protective layer that inhibits further wear degradation of the alloy and decreases its corrosion tendency.
Source: europepmc · Quality: candidate unverified · Source record ↗
Research context
OpenAlex topics: Orthopaedic implants and arthroplasty · Advanced materials and composites · Titanium Alloys Microstructure and Properties
SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.
References (32)
Show source-provided references
1. Wear analysis of materials used as orthopaedic implants10.1016/j.wear.2006.03.022 ↗
2. Uncemented and cemented primary total hip arthroplasty in the Swedish Hip Arthroplasty Register. Evaluation of 170,413 operations10.3109/17453671003685400 ↗
3. Tribocorrosion behavior of CoCrMo alloy for hip prosthesis as a function of loads: a comparison between two testing systems10.1016/j.wear.2011.01.086 ↗
4. S. Williams, J.L. Tipper, E. Ingham, M.H. Stone, Fisher J. In vitro analysis of the wear, wear debris and biological activity of surface-engineered coatings for use in metal-on-metal total hip replacements. In: Proceedings of the institution of mechanical engineers, Part H, J Eng Med. 2003;217(3):pp. 155–63.10.1243/095441103765212659 ↗
5. Failure analysis of three uncemented titanium-alloy modular total hip stems10.1016/j.engfailanal.2010.02.011 ↗
6. Influence of fretting regimes on the tribocorrosion behaviour of Ti6Al4V in 0.9wt.% sodium chloride solution10.1016/j.wear.2003.11.003 ↗
7. Wear mechanisms in metal-on-metal bearings: the importance of tribochemical reaction layers
8. Tribolayer formation in a metal-on-metal (MoM) hip joint: an electrochemical investigation10.1016/j.jmbbm.2013.08.018 ↗
9. EBSD, SEM and FIB characterisation of subsurface deformation during tribocorrosion of stainless steel in sulphuric acid10.1016/j.wear.2010.04.023 ↗
10. Effects of physiological mechanical strains on the release of growth factors and the expression of differentiation marker genes in human osteoblasts growing on Ti–6Al–4V10.1002/jbm.a.32105 ↗
11. Estimation of hydrodynamic shear stresses developed on human osteoblasts cultured on Ti–6Al–4V and strained by four point bending. Effects of mechanical loading to specific gene expression
12. Titanium is not “the most biocompatible metal” under cathodic potential: the relationship between voltage and MC3T3 preosteoblast behavior on electrically polarized cpTi surfaces10.1002/jbm.a.32622 ↗
13. The effect of cathodic electrochemical potential of Ti–6Al–4V on cell viability: voltage threshold and time dependence10.1002/jbm.b.32970 ↗
14. Polymeric piezoelectric actuator substrate for osteoblast mechanical stimulation10.1016/j.jbiomech.2009.12.010 ↗
15. Third body effects and material fluxes in tribocorrosion systems involving a sliding contact10.1016/S0043-1648(03)00561-1 ↗
16. Tribocorrosion response of the Ti6Al4V alloys commonly used in femoral stems10.1016/j.triboint.2013.09.022 ↗
17. Evaluation of human osteoblastic cell response to plasma-sprayed silicon-substituted hydroxyapatite coatings over titanium substrates10.1002/jbm.b.31656 ↗
18. Nanocrystalline diamond: In vitro biocompatibility assessment by MG63 and human bone marrow cells cultures10.1002/jbm.a.31742 ↗
19. Acrylic formulations containing bioactive and biodegradable fillers to be used as bone cements: properties and biocompatibility assessment10.1016/j.msec.2012.12.028 ↗
20. A comparative study of cellular uptake and cytotoxicity of multi-walled carbon nanotubes, graphene oxide, and nanodiamond10.1039/c2tx20006f ↗
21. A comparative cytotoxicity study of TiO2 nanoparticles under light and dark conditions at low exposure concentrations10.1039/c2tx00012a ↗
22. Surface modification of titanium, titanium alloys, and related materials for biomedical applications10.1016/j.mser.2004.11.001 ↗
23. Study of the biotribocorrosion behaviour of titanium biomedical alloys in simulated body fluids by electrochemical techniques10.1016/j.wear.2012.04.014 ↗
24. Effect of surface treatment on electrochemical behavior of CP Ti, Ti–6Al–4V and Ti–13Nb–13Zr alloys in simulated human body fluid10.1016/j.corsci.2005.06.003 ↗
25. 2008
26. Tribological, electrochemical and tribo-electrochemical characterization of bare and nitrided Ti6Al4V in simulated body fluid solution10.1016/j.corsci.2011.01.057 ↗
27. A study of the potentials achieved during mechanical abrasion and the repassivation rate of titanium and Ti6Al4V in inorganic buffer solutions and bovine serum10.1016/j.electacta.2004.07.024 ↗
28. Corrosion behavior and surface characterization of titanium in solution containing fluoride and albumin10.1016/j.biomaterials.2004.03.025 ↗
29. Effect of fluoride and albumin concentration on the corrosion behavior of Ti–6Al–4V alloy10.1016/S0142-9612(02)00315-0 ↗
30. Interfacial kinetics of titanium- and cobalt-based implant alloys in human serum: metal release and biofilm formation10.1002/jbm.a.10429 ↗
31. The corrosion behaviour of Ti–6Al–4V, Ti–6Al–7Nb and Ti–13Nb–13Zr in protein solutions10.1016/S0142-9612(98)00217-8 ↗
32. The influence of proteins on the fretting-corrosion behaviour of a Ti6Al4V alloy10.1016/j.wear.2006.03.032 ↗