journal article·2014-08

A novel silk-based artificial ligament and tricalcium phosphate/polyether ether ketone anchor for anterior cruciate ligament reconstruction – Safety and efficacy in a porcine model

Xiang Li, Jiankang He, Weiguo Bian, Zheng Li, Wenyou Zhang, Dichen Li, Jess G. Snedeker

Acta Biomaterialia· Volume 10· Issue 8
Publisher page

Abstract

Loss of ligament graft tension in early postoperative stages following anterior cruciate ligament (ACL) reconstruction can come from a variety of factors, with slow graft integration to bone being widely viewed as a chief culprit. Toward an off-the-shelf ACL graft that can rapidly integrate to host tissue, we have developed a silk-based ACL graft combined with a tricalcium phosphate (TCP)/polyether ether ketone anchor. In the present study we tested the safety and efficacy of this concept in a porcine model, with postoperative assessments at 3months (n=10) and 6months (n=4). Biomechanical tests were performed after euthanization, with ultimate tensile strengths at 3months of ∼370N and at 6months of ∼566N - comparable to autograft and allograft performance in this animal model. Comprehensive histological observations revealed that TCP substantially enhanced silk graft to bone attachment. Interdigitation of soft and hard tissues was observed, with regenerated fibrocartilage characterizing a transitional zone from silk graft to bone that was similar to native ligament bone attachments. We conclude that both initial stability and robust long-term biological attachment were consistently achieved using the tested construct, supporting a large potential for silk-TCP combinations in the repair of the torn ACL.
Source: europepmc · Quality: candidate unverified · Source record ↗

Research context

OpenAlex topics: Knee injuries and reconstruction techniques · Silk-based biomaterials and applications · Bone Tissue Engineering Materials

SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.

References (46)

Show source-provided references
1. The risk for a cruciate ligament injury of the knee in adolescents and young adults: a population-based cohort study of 46,500 people with a 9year follow-up10.1136/bjsm.2008.046185 ↗
2. Recent advancements in ligament tissue engineering: the use of various techniques and materials for ACL repair10.2174/1874764710801010018 ↗
3. Junkin · 2009
4. A hybrid silk/RADA-based fibrous scaffold with triple hierarchy for ligament regeneration10.1089/ten.tea.2011.0376 ↗
5. History of ACL treatment and current gold standard of care
6. Controversies in ACL reconstruction: bone–patellar tendon–bone anterior cruciate ligament reconstruction remains the gold standard10.1097/JSA.0b013e3181c14841 ↗
7. Medium to long-term follow-up after ACL revision10.1007/s00167-011-1629-3 ↗
8. Long-term follow-up of patellar tendon grafts or hamstring tendon grafts in endoscopic ACL reconstructions
9. ACL prosthesis: any promise for the future?10.1007/s00167-009-0982-y ↗
10. Trends in surgeon preferences on anterior cruciate ligament reconstructive techniques10.1016/j.csm.2012.08.011 ↗
11. The remains of anterior cruciate ligament graft tension after cyclic knee motion10.1177/0363546504269938 ↗
12. Anterior knee pain after ACL reconstruction: how to avoid it
13. Tunnel widening following anterior cruciate ligament reconstruction using hamstring autograft: a comparison between double cross-pin and suspensory graft fixation10.1007/s00167-008-0606-y ↗
14. A comparison of rabbit mesenchymal stem cells and anterior cruciate ligament fibroblasts responses on combined silk scaffolds10.1016/j.biomaterials.2007.11.023 ↗
15. Anterior cruciate ligament regeneration using mesenchymal stem cells and silk scaffold in large animal model10.1016/j.biomaterials.2009.05.048 ↗
16. Tendons: engineering of functional tissues
17. Silk matrix for tissue engineered anterior cruciate ligaments10.1016/S0142-9612(02)00156-4 ↗
18. Silk-based biomaterials10.1016/S0142-9612(02)00353-8 ↗
19. Yarn design for functional tissue engineering10.1016/j.jbiomech.2005.07.007 ↗
20. The use of long-term bioresorbable scaffolds for anterior cruciate ligament repair10.5435/00124635-200804000-00001 ↗
21. Biological and biomechanical assessment of a long-term bioresorbable silk-derived surgical mesh in an abdominal body wall defect model10.1007/s10029-008-0459-9 ↗
22. Development of a silk and collagen fiber scaffold for anterior cruciate ligament reconstruction10.1007/s10856-012-4781-5 ↗
23. Characterization of electrospun substrates for ligament regeneration using bone marrow stromal cells10.1007/978-3-540-92841-6_368 ↗
24. Horan · 2009
25. Engineering fibrous tissues and their interfaces with bone
26. In vitro ligament–bone interface regeneration using a trilineage coculture system on a hybrid silk scaffold10.1021/bm300651q ↗
27. An analysis of soft tissue allograft anterior cruciate ligament reconstruction in a rabbit model – a short-term study of the use of mesenchymal stem cells to enhance tendon osteointegration10.1177/0363546507300057 ↗
28. Enhanced regeneration of the ligament–bone interface using a poly(l-lactide-co-epsilon-caprolactone) scaffold with local delivery of cells/BMP-2 using a heparin-based hydrogel10.1016/j.actbio.2010.08.017 ↗
29. The role of transforming growth factor beta isoforms in tendon-to-bone healing10.3109/03008207.2010.483026 ↗
30. Bioceramics of calcium orthophosphates10.1016/j.biomaterials.2009.11.050 ↗
31. Embossing of a screw thread and TCP granules enhances the fixation strength of compressed ACL grafts with interference screws10.1007/s00167-011-1623-9 ↗
32. Variation of the effect of calcium phosphate enhancement of implanted silk fibroin ligament bone integration10.1016/j.biomaterials.2013.04.046 ↗
33. A novel silk–TCP–PEEK construct for anterior cruciate ligament reconstruction: an off-the-shelf alternative to a bone–tendon–bone autograft10.1088/1758-5082/6/1/015010 ↗
34. Wired silk architectures provide a biomimetic ACL tissue engineering scaffold10.1016/j.jmbbm.2013.03.015 ↗
35. Long term mechanical behavior of silk ACL scaffolds under cyclic loading10.1016/S0021-9290(12)70326-3 ↗
36. Fabrication of porous beta-tricalcium phosphate with microchannel and customized geometry based on gel-casting and rapid prototyping
37. A comparison of five tibial-fixation systems in hamstring-graft anterior cruciate ligament reconstruction10.1007/s00167-003-0488-y ↗
38. In vivo models of ACL injury (central defect, porcine, ovine, canine)
39. Basic methods in histopathology of joint tissues10.1016/j.joca.2010.05.026 ↗
40. A bFGF-releasing silk/PLGA-based biohybrid scaffold for ligament/tendon tissue engineering using mesenchymal progenitor cells10.1016/j.biomaterials.2010.01.004 ↗
41. Biomechanical outcomes after bioenhanced anterior cruciate ligament repair and anterior cruciate ligament reconstruction are equal in a porcine model10.1016/j.arthro.2011.10.008 ↗
42. Comparison of femoral fixation methods for anterior cruciate ligament reconstruction with patellar tendon graft: a mechanical analysis in porcine knees10.1007/s00167-006-0269-5 ↗
43. In Vivo Study of ACL Regeneration Using Silk Scaffolds In a Pig Model10.1007/978-3-540-92841-6_374 ↗
44. Aligned hybrid silk scaffold for enhanced differentiation of mesenchymal stem cells into ligament fibroblasts10.1089/ten.tec.2010.0513 ↗
45. Tendon–bone healing enhancement using injectable tricalcium phosphate in a dog anterior cruciate ligament reconstruction model10.1016/j.arthro.2006.12.031 ↗
46. Effect of bone morphogenetic protein 2 on tendon-to-bone healing in a canine flexor tendon model10.1002/jor.22151 ↗