Ruthenium oxide based microelectrode arrays for in vitro and in vivo neural recording and stimulation
Source abstract
Abstract
We have characterized the in vitro and in vivo extracellular neural recording and stimulation properties of ruthenium oxide (RuOx) based microelectrodes. Cytotoxicity and functional neurotoxicity assays were carried out to confirm the in vitro biocompatibility of RuOx. Material extract assays, in accordance to ISO protocol "10993-5: Biological evaluation of medical devices", revealed no significant effect on neuronal cell viability or the functional activity of cortical networks. In vitro microelectrode arrays (MEAs), with indium tin oxide (ITO) sites modified with sputtered iridium oxide (IrOx) and RuOx in a single array, were developed for a direct comparison of electrochemical and recording performance of RuOx to ITO and IrOx deposited microelectrode sites. The impedance of the RuOx-coated electrodes measured by electrochemical impedance spectroscopy was notably lower than that of ITO electrodes, resulting in robust extracellular recordings from cortical networks in vitro. We found comparable signal-to-noise ratios (SNRs) for RuOx and IrOx, both significantly higher than the SNR for ITO. RuOx-based MEAs were also fabricated and implanted in the rat motor cortex to demonstrate manufacturability of the RuOx processing and acute recording capabilities in vivo. We observed single-unit extracellular action potentials with a SNR >22, representing a first step for neurophysiological recordings in vivo with RuOx based microelectrodes. STATEMENT OF SIGNIFICANCE: A critical challenge in neural interface technology is the development of microelectrodes that have recording and electrical stimulation capabilities suitable for bidirectional communication between the external electronic device and the nervous system. The present study explores the feasibility and functional capabilities of ruthenium oxide microelectrodes as a neural interface. Significant improvement in electrochemical properties and neuronal recordings are reported when compared to commercially available indium tin oxide and was similar to that of iridium oxide electrodes. The data demonstrate the potential for future development of chronic neural interfaces using ruthenium oxide based microelectrodes for recording and stimulation.
Source: europepmc · Quality: candidate unverified · Source record ↗
Research context
OpenAlex topics: Neuroscience and Neural Engineering · Conducting polymers and applications · Advanced Memory and Neural Computing
SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.
References (37)
Show source-provided references
1. Chronic recording capability of the Utah intracortical electrode array in cat sensory cortex10.1016/S0165-0270(98)00031-4 ↗
2. Personalized neuroprosthetics10.1126/scitranslmed.3005968 ↗
3. Acute human brain responses to intracortical microelectrode arrays : challenges and future prospects10.3389/fneng.2014.00024 ↗
4. Alternating current stimulation for vision restoration after optic nerve damage: a randomized clinical trial10.1371/journal.pone.0156134 ↗
5. The science of neural interface systems10.1146/annurev.neuro.051508.135241 ↗
6. Electrical stimulation of the auditory nerve: the effect of electrode position on neural excitation10.1016/0378-5955(93)90265-3 ↗
7. Revealing neuronal function through microelectrode array recordings
8. Neural stimulation and recording electrodes10.1146/annurev.bioeng.10.061807.160518 ↗
9. High-throughput in vitro assay to evaluate the cytotoxicity of liberated platinum compounds for stimulating neural electrodes10.1016/j.jneumeth.2016.07.018 ↗
10. Electrical stimulation with Pt electrodes. VIII. Electrochemically safe charge injection limits with 0.2 ms pulses10.1109/10.61038 ↗
11. In vitro comparison of sputtered iridium oxide and platinum-coated neural implantable microelectrode arrays10.1088/1748-6041/5/1/015007 ↗
12. Extracellular recordings from patterned neuronal networks using planar microelectrode arrays10.1109/TBME.2004.827252 ↗
13. Surface-modified microelectrode array with flake nanostructure for neural recording and stimulation
14. Tailoring the cap's morphology of electrodeposited gold micro-mushrooms10.1016/j.apsusc.2018.03.158 ↗
15. Microfabricated cylindrical multielectrodes for neural stimulation10.1109/TBME.2005.862552 ↗
16. Marissa brooks, and D. S. H. rough gold electrodes for decreasing impedance at the electrolyte/electrode interface
17. Gold nanostructure microelectrode arrays for in vitro recording and stimulation from neuronal networks10.1088/1361-6528/ab07cd ↗
18. Poly(3,4-ethylenedioxythiophene) (PEDOT) polymer coatings facilitate smaller neural recording electrodes10.1088/1741-2560/8/1/014001 ↗
19. Carbon nanotube coating improves neuronal recordings10.1038/nnano.2008.174 ↗
20. Electrodeposited iridium oxide for neural stimulation and recording electrodes10.1109/7333.918271 ↗
21. Supercapacitance of ruthenium oxide deposited on titania and titanium substrates10.1016/j.matchemphys.2010.03.011 ↗
22. Electrochemical characterization of electrochemically prepared ruthenium oxide/carbon nanotube electrode for supercapacitor application10.1149/1.1925067 ↗
23. Planar ruthenium oxide sensors for cell-on-a-chip metabolic studies. Planar ruthenium oxide sensors cell-on-a-chip
24. Large charge-storage-capacity iridium/ruthenium oxide coatings as promising material for neural stimulating electrodes10.1016/j.matchemphys.2015.03.061 ↗
25. Characterization of ruthenium electrodes for implantable neurostimulation applications
26. Use of cortical neuronal networks for in vitro material biocompatibility testing10.1016/j.bios.2013.10.002 ↗
27. In vitro compatibility testing of thiol-ene/acrylate-based shape memory polymers for use in implantable neural interfaces10.1002/jbm.a.36478 ↗
28. Liquid crystal elastomer-based microelectrode array for in vitro neuronal recordings10.3390/mi9080416 ↗
29. Chronic intracortical recording and electrochemical stability of thiol-ene/acrylate shape memory polymer electrode arrays
30. Kurzweil, P.; Hartmann, H.; Schell, C.The redox chemistry of ruthenium dioxide : a cyclic voltammetry study — review and revision. 2018, 2018.10.1155/2018/1273768 ↗
31. Iridium oxide microelectrode arrays for in-vitro stimulation of individual rat neurons from dissociated cultures10.3389/neuro.16.016.2009 ↗
32. Structure of hydrous ruthenium oxides : implications for charge storage10.1021/jp990096n ↗
33. Electrochemical reduction of carbon dioxide at ruthenium dioxide deposited on boron-doped diamond10.1023/B:JACH.0000003866.85015.b6 ↗
34. Reduction of carbon dioxide on ruthenium oxide and modified ruthenium oxide electrodes in 0.5M NaHCO3
35. Enhanced oxygen evolution on an electrodeposited ruthenium + iridium coating on titanium10.1016/0022-0728(95)03873-F ↗
36. Preparation and surface characterization of Ti/SnO2–RuO2–IrO2 thin films as electrode material for the oxidation of phenol10.1016/j.matchemphys.2005.02.022 ↗
37. Influence of electrolyte composition on deactivationmechanism of a Ti/Ru0.25Ir0.25Ti0.5O2 electrode10.1007/s11581-012-0737-5 ↗