Low-density polypropylene meshes coated with resorbable and biocompatible hydrophilic polymers as controlled release agents of antibiotics
Source abstract
Abstract
The application of bioactive meshes in abdominal surgery for the repair of hernias is an increasing clinical activity in a wide sector of the population. The main secondary effect is the appearance of infections from bacteria, specifically Staphylococcus aureus and S. epidermidis. This paper describes the development and application of low-density polypropylene meshes coated with a biocompatible and resorbable polymer as a controlled release system of the antibiotic vancomycin. The polymeric coating (a non-cross-linked copolymer of 2-hydroxyethyl methacrylate and 2-acrylamido-2-methylpropanesulfonic acid) has a thickness of 14-15μm and contains 0.32mgcm(-2) of the antibiotic vancomycin. The in vitro experiments demonstrate the excellent inhibitory character of the coated meshes loaded with the antibiotic, following the standard protocol of inhibition of halo in agar diffusion test. This inhibitory effect is maintained for a relatively long period (at least 14days) with a low concentration of antibiotic. The acrylic polymer system regulates the release of the antibiotic with a rate of 24μgh(-1), due to its slow dissolution in the medium. Experiments in vivo, based on the implantation of coated meshes, demonstrate that the system controls the infection in the animal (rabbits) for at least 30days. The concentration of antibiotic in the blood stream of the rabbits was below the detection limit of the analytical technique (<1-2μgml(-1)), which demonstrates that the antibiotic is released in the local area of the implant and remains concentrated at the implantation site, without diffusion to the blood stream. The systems can be applied to other medical devices and implants for the application of new-generation antibiotics in a controlled release and targeted applications.
Source: europepmc · Quality: candidate unverified · Source record ↗
Research context
OpenAlex topics: Hernia repair and management · Surgical Sutures and Adhesives · Surgical site infection prevention
SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.
References (25)
Show source-provided references
1. Complications of open groin hernia repair10.1016/S0039-6109(03)00128-2 ↗
2. Hernia repair with marlex mesh10.1001/archsurg.1962.01300210059012 ↗
3. The tension-free hernioplasty10.1016/0002-9610(89)90526-6 ↗
4. Relationship between tissue in growth and mesh contraction10.1007/s00268-005-7786-0 ↗
5. The lightweight and large porous mesh concept for hernia repair10.1586/17434440.2.1.103 ↗
6. Infection risk of open placement of intraperitoneal composite mesh10.1177/000313480907500905 ↗
7. Cyclodextrin and maltodextrin finishing of a polypropylene abdominal wall implant for the prolonged delivery of ciprofloxacin10.1016/j.actbio.2011.04.020 ↗
8. Intraperitoneal onlay mesh: an experimental study of adhesion formation in a sheep model10.1007/s10029-009-0622-y ↗
9. Infection in breast implants10.1016/S1473-3099(05)70084-0 ↗
10. The phenomenon of infection with abdominal wall reconstruction10.1016/j.biomaterials.2007.01.028 ↗
11. Do multifilament alloplastic meshes increase the infection rate? Analysis of the polymeric surface, the bacteria adherence, and the in vivo consequences in a rat model10.1002/jbm.10449 ↗
12. Antibiotic prophylaxis for hernia repair
13. New antibiotic-eluting mesh used for soft tissue reinforcement10.1016/j.actbio.2011.05.009 ↗
14. In vivo evaluation of bacterial infection involving morphologically different surgical meshes10.1097/SLA.0b013e3181b61d9a ↗
15. Infections from biomaterials and implants: a race for the surface
16. Antimicrobial effects of an NO-realising poly(ethylene vinylacetate) coating on soft-tissue implants in vitro in a murine model10.1016/j.actbio.2009.01.041 ↗
17. Intrinsic viscosity-molecular weight relationships for poly(2-hydroxyethyl methacrylate)10.1016/0014-3057(76)90036-7 ↗
18. Clinical and Laboratory Standards Institute, Methods for Determining Bactericidal Activity of Antimicrobial Agents. Approved guideline M26-A. NCCLS, Wayne, PA 1999.
19. Rodríguez G, Fernández-Gutiérrez M, Parra J, López-Bravo A,. Molina M, Duocastella L, San Román J.J. of Bioactive and Compatible Polymers, in press.
20. In vitro infectability of prosthetic mesh by methicillin-resistant Staphylococcus aureus10.1007/s10029-005-0056-0 ↗
21. In vitro and in vivo assessment of silver-coated polypropylene mesh to prevent infection in a rat model10.1007/s00192-010-1330-y ↗
22. Gold and Gold-Palladium coated polypropylene grafts in a S. epidermidis wound infection model10.1016/j.jss.2005.06.020 ↗
23. Gentamicin supplementation of polyvinylidenfluoride mesh materials for infection prophylaxis10.1016/j.biomaterials.2004.02.070 ↗
24. Improved collagen type I/III ratio at the interface of gentamicin-supplemented polyvinylidenfluoride mesh materials10.1007/s00423-006-0138-1 ↗
25. Antibiotic-releasing mesh coating to reduce prosthetic sepsis: an in vivo study10.1016/j.jss.2010.03.065 ↗