Mechanical response of human subclavian and iliac arteries to extension, inflation and torsion

Gerhard Sommer, Christoph Benedikt, Justyna A. Niestrawska, Gloria Hohenberger, Christian Viertler, Peter Regitnig, Tina U. Cohnert, Gerhard A. Holzapfel

Acta Biomaterialia· Volume 75
Publisher page

Abstract

Peripheral vascular trauma due to injuries of the upper and lower limbs are life-threatening, and their treatment require rapid diagnosis and highly-qualified surgical procedures. Experienced surgeons have recognized that subclavian arteries, affected by injuries of the upper limbs, require a more careful handling due to fragility than common iliac arteries, which are may be affected by injures of the lower limbs. We investigated these two artery types with comparable diameter to evaluate the differences in the biomechanical properties between subclavian and iliac arteries. Human subclavian and common iliac arteries of 14 donors either from the right or the left side (age: 63 yrs, SD: 19,9 female and 5 male) were investigated. Extension-inflation-torsion experiments at different axial strains (0-20%), transmural pressures (0-200 mmHg) and torsion (±25°) on preconditioned arterial tubes were performed. Residual stresses in both circumferential and axial direction were determined. Additionally, the microstructure of the tissues was determined via second-harmonic generation imaging and by histological investigations. At physiological conditions (pi=13.3 kPa, λz=1.1) common iliac arteries revealed higher Cauchy stresses in circumferential and axial directions but a more compliant response in the circumferential direction than subclavian arteries. Both arteries showed distinct stiffer behavior in circumferential than in axial direction. Circumferential stiffness of common iliac arteries at physiological conditions increased significantly with aging (r=-0.67,p=0.02). The median inversion stretches, where the axial force is basically independent of the transmural pressure, were determined to be 1.05 for subclavian arteries and 1.11 for common iliac arteries. Both arteries exhibited increased torsional stiffness, when either axial prestretch or inflation pressure was increased. Residual stresses in the circumferential direction were significantly lower for subclavian arteries than for common iliac arteries at measurements after 30 min (p=0.05) and 16hrs (p=0.01). Investigations of the collagen microstructure revealed different collagen fiber orientations and dispersions in subclavian and iliac arteries. The difference in the collagen microstructure revealed further that the adventitia seems to contribute significantly to the passive mechanical response of the tested arteries at physiological loadings. Histological investigations indicated pronounced thickened intimal layers in subclavian and common iliac arteries, with a thickness comparable to the adventitial layer. In conclusion, we obtained biomechanical differences between subclavian and common iliac arteries, which possibly resulted from their different mechanical loadings/environments and respective in vivo movements caused by their anatomical locations. The biomechanical differences explored in this study are well reflected by the microstructure of the collagen and the histology of the investigated arteries, and the results can improve trauma patient care and endovascular implant design. Statement of significance During surgical interventions surgeons experienced that subclavian arteries (SAs) supplying the upper extremities, appear more fragile and prone to damage during surgical repair than common iliac arteries (CIAs), supplying the lower extremities. To investigate this difference in a systematic way the aim of this study was to compare the biomechanical properties of these two arteries from the same donors in terms of geometry, extension-inflation-torsion behavior, residual stresses, microstructure, and histology. In regard to cardiovascular medicine the material behavior of aged human arteries is of crucial interest. Moreover, the investigation of SA is important as it can help to improve surgical procedures at this challenging location. Over the long-term it might well be of value in the construction of artificial arteries for substituting native arteries. In addition, the analysis of mechanical stresses can improve design and material choice for endovascular implants to optimize long-term implant function.
Source: europepmc · Quality: candidate unverified · Source record ↗

Research context

OpenAlex topics: Peripheral Artery Disease Management · Muscle and Compartmental Disorders · Aortic aneurysm repair treatments

SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.

References (29)

Show source-provided references
1. Extremity vascular trauma in civilian population: a seven-year review from North India10.1016/j.injury.2004.06.017 ↗
2. Extremities–indications and techniques for treatment of extremity vascular injuries10.1016/j.injury.2008.02.043 ↗
3. Civilian traumatic vascular injuries of the upper extremity: report of the Iranian national trauma project
4. The predictors of poor outcomes in patients with femoral artery injuries
5. Subclavian stents and stent-grafts: cause for concern?10.1583/1074-6218(1999)006<0223:SSASCF>2.0.CO;2 ↗
6. Description of a new angiographic sign: dynamic left subclavian artery obstruction
7. In vivo deformation of the human abdominal aorta and common iliac arteries with hip and knee flexion: implications for the design of stent-grafts10.1583/09-2806.1 ↗
8. Passive biaxial mechanical response of aged human iliac arteries10.1115/1.1574331 ↗
9. Computer-aided vascular experimentation: a new electromechanical test system10.1007/BF02368162 ↗
10. Biaxial mechanical properties of the human thoracic and abdominal aorta, common carotid, subclavian, renal and common iliac arteries10.1007/s10237-014-0576-6 ↗
11. Layer-specific 3D residual deformations of human aortas with non-atherosclerotic intimal thickening10.1007/s10439-006-9252-z ↗
12. Biaxial mechanical properties of intact and layer–dissected human carotid arteries at physiological and supra-physiological loadings10.1152/ajpheart.00378.2009 ↗
13. Change of residual strains in arteries due to hypertrophy caused by aortic constriction10.1161/01.RES.65.5.1340 ↗
14. Effects of age on the physiological and mechanical characteristics of human femoropopliteal arteries10.1016/j.actbio.2014.09.050 ↗
15. An automated approach for three-dimensional quantification of fibrillar structures in optically cleared soft biological tissues10.1098/rsif.2012.0760 ↗
16. Modelling non-symmetric collagen fibre dispersion in arterial walls10.1098/rsif.2015.0188 ↗
17. Microstructure and mechanics of healthy and aneurysmatic abdominal aortas: experimental analysis and modeling10.1098/rsif.2016.0620 ↗
18. Determination of the layer-specific distributed collagen fiber orientations in human thoracic and abdominal aortas and common iliac arteries10.1098/rsif.2011.0727 ↗
19. The elastic symmetry of arterial segments in dogs10.1161/01.RES.24.1.1 ↗
20. Mechanics of the human femoral adventitia including high-pressure response10.1152/ajpheart.00397.2001 ↗
21. Analysis of the passive mechanical properties of rat carotid arteries10.1016/0021-9290(83)90080-5 ↗
22. Humphrey · 2002
23. MATLAB. R2016a, The MathWorks Inc., Natick, MA, USA, 2016.
24. Length-force and volume-pressure relationships of arteries
25. New experiments on shear modulus of elasticity of arteries10.1152/ajpheart.1994.266.1.H1 ↗
26. Shear modulus of porcine coronary artery: contributions of media and adventitia10.1152/ajpheart.00357.2003 ↗
27. Determination of the shear modulus of human blood-vessel walls10.1007/BF00860800 ↗
28. A new constitutive framework for arterial wall mechanics and a comparative study of material models10.1023/A:1010835316564 ↗
29. Effects of norepinephrine on mechanics of arteries in vitro10.1152/ajplegacy.1976.231.2.420 ↗