Formation, mechanical properties and corrosion resistance of Ti–Pd base glassy alloys
Source abstract
Abstract
Abstract No biocompatible Ti-based glassy alloys without a harmful element have been reported. We have examined the mechanical and chemical properties of Ti–Pd–Zr–Si glassy alloy in comparison with pure Ti metal and Ti–6Al–4V alloy which have been used so far for biomaterials. The present Ti–Pd base glassy alloys do not contain Al and Ni elements which are considered to be rather toxic. Melt-spun Ti 45 Zr 50− x Pd x Si 5 glassy alloy ribbons ( x = 35, 40, 45) exhibited good bend ductility and had higher Vickers’s hardness and lower Young’s modulus as compared to pure titanium and Ti–6Al–4V alloy. In addition, the Ti 45 Zr 50− x Pd x Si 5 glassy alloys had higher corrosion resistance and were passivated over a wide range and at the lower passive current density of approximately 10 −2 Am −2 than at of pure titanium and Ti–6Al–4V alloy in 1 mass% lactic acid and PBS(−) solutions at 310 K.
Source: openaire · Quality: candidate unverified · Source record ↗
Research context
OpenAlex topics: Metallic Glasses and Amorphous Alloys · High Entropy Alloys Studies · Shape Memory Alloy Transformations
SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.
References (26)
Show source-provided references
1. Long · Biomaterials · 1998 · 19 · 162110.1016/S0142-9612(97)00146-4 ↗
2. Wang · Mater. Sci. Eng. A · 1996 · 213 · 13410.1016/0921-5093(96)10243-4 ↗
3. G.S. Steinemann, Corrosion of titanium and titanium alloys for surgical implants, in: G. Lütjering, U. Zwicker and W. Bunk (Eds.), Ti ‘84 Science and Technology, 1984, p. 1373.
4. G.S. Steinemann and S.M. Perren, Titanium as metallic biomaterials, in: G. Lütjering, U. Zwicker and W. Bunk (Eds.), Ti ‘84 Science and Technology, 1984, p. 1327.
5. Corrosion of surgical implants-in vivo and in vitro tests
6. Injury10.1016/S0020-1383(00)80017-0 ↗
7. Hattori · Mater. Sci. Eng. C · 2001 · 17 · 2710.1016/S0928-4931(01)00331-9 ↗
8. Meyer · Clin. Biomechan. · 2003 · 18 · 97510.1016/S0268-0033(03)00181-5 ↗
9. Liu · J. Arthroplast. · 1997 · 12 · 710.1016/S0883-5403(97)90007-3 ↗
10. Korovessis · Eur. J. Orthop. Surg. Traumatol. · 2002 · 12 · 6110.1007/s00590-002-0017-6 ↗
11. Rockwood · 1996 · vol. 1
12. Meydan · Sensor Actuator A · 1997 · 59 · 19210.1016/S0924-4247(97)80172-0 ↗
13. Hiromoto · Corros. Sci. · 2001 · 43 · 176710.1016/S0010-938X(00)00168-2 ↗
14. Inoue · Acta Mater. · 2000 · 48 · 27910.1016/S1359-6454(99)00300-6 ↗
15. Zhang · Mater. Sci. Eng. · 2001 · A304 · 77110.1016/S0921-5093(00)01592-6 ↗
16. Zhang · Mater. Trans. JIM · 1998 · 39 · 100110.2320/matertrans1989.39.1001 ↗
17. Wang · Mater. Sci. Eng. · 2004 · R44 · 45
18. Kim · Mater. Trans. JIM · 2002 · 43 · 124310.2320/matertrans.43.1243 ↗
19. Oak · Mater. Sci. Eng. A · 2007 · 449 · 22010.1016/j.msea.2006.02.307 ↗
20. Inoue · J. Appl. Phys. · 1980 · 51 · 547510.1063/1.327506 ↗
21. Inoue · J. Phys. · 1980 · 41 · C8-758
22. Tarasova · Fig. Met. Metalloved. · 1992 · 2 · 96
23. Ishmaev · Physica B: Condensed Matter · 2004 · 350 · E110710.1016/j.physb.2004.03.301 ↗
24. Jankowski · J. Less Common Metals · 1990 · 161 · 11510.1016/0022-5088(90)90320-J ↗
25. Tomioka · J. Mater. Proce. Tech. · 2004 · 146 · 22810.1016/j.jmatprotec.2003.11.017 ↗
26. Landau · 1970