Biosafety, stability, and osteogenic activity of novel implants made of Zr70Ni16Cu6Al8 bulk metallic glass for biomedical application
Source abstract
Abstract
Superior mechanical and chemical properties of Zr70Ni16Cu6Al8 bulk metallic glass (BMG) demonstrate its promise as a novel biomaterial for fabrication of implants. The aim of the present study was to validate mechanical, chemical, and biological properties of Zr70Ni16Cu6Al8 BMG through comparison with titanium (Ti). Our data indicated higher tensile strength, lower Young's modulus, and reduced metal ion release of Zr70Ni16Cu6Al8 BMG compared with Ti. Biosafety of bone marrow mesenchymal cells on Zr70Ni16Cu6Al8 BMG was comparable to that of Ti. Next, screw-type implant prototypes made of Zr70Ni16Cu6Al8 BMG were fabricated and inserted into rat long bones. Zr70Ni16Cu6Al8 BMG implants indicated a higher removal-torque value and lower Periotest value compared with Ti implants. In addition, higher amounts of new bone formation and osseointegration were observed around Zr70Ni16Cu6Al8 BMG implants compared with Ti implants. Moreover, gene expression analysis displayed higher expression of osteoblast- and osteoclast-associated genes in the Zr70Ni16Cu6Al8 BMG group compared with the Ti group. Importantly, loading to implants upregulated bone formation, as well as osteoblast- and osteoclast-associated gene expression in the peri-implant area. No significant difference in concentrations of Ni, Al, Cu, and Zr in various organs was shown between in the Zr70Ni16Cu6Al8 BMG and Ti groups. Collectively, these findings suggest that Zr70Ni16Cu6Al8 BMG is suitable for fabricating novel implants with superior mechanical properties, biocompatibility, stability, and biosafety compared with Ti. Statement of significance Titanium is widely used to fabricate orthopedic and dental implants. However, Titanium has disadvantages for biomedical applications in regard to strength, elasticity, and biosafety. Recently, we developed a novel hypoeutectic Zr70Ni16Cu6Al8 BMG, which has superior mechanical and chemical properties. However, the validity of Zr70Ni16Cu6Al8 BMG for biomedical application has not been cleared. The aim of the present study was to validate the mechanical, chemical, and biological properties of Zr70Ni16Cu6Al8 BMG for biomedical applications through comparison with Titanium. The present study clarifies that Zr70Ni16Cu6Al8 BMG has good mechanical properties, corrosion resistance, and osteogenic activity, which are necessary features for biomedical applications. The present study provides for the first time the superiority of Zr70Ni16Cu6Al8 BMG implants to Titanium implants for biomedical applications.
Source: europepmc · Quality: candidate unverified · Source record ↗
Research context
OpenAlex topics: Bone Tissue Engineering Materials · Metallic Glasses and Amorphous Alloys · High Entropy Alloys Studies
SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.
References (70)
Show source-provided references
1. Proffit · 2013 · 295
2. Rigid endosseous implant utilized as anchorage to protract molars and close an atrophic extraction site
3. Titanium screw anchorage for correction of canted occlusal plane in patients with facial asymmetry10.1016/j.ajodo.2005.12.032 ↗
4. Distalization of the entire maxillary arch in an adult10.1016/j.ajodo.2008.01.015 ↗
5. Titanium alloys in total joint replacement–a materials science perspective10.1016/S0142-9612(97)00146-4 ↗
6. Biomaterials in orthopaedics10.1098/rsif.2008.0151 ↗
7. Osseointegrated implant fracture: causes and treatment10.1563/AAID-JOI-D-09-00135.1 ↗
8. BMP-induced osteogenesis on the surface of hydroxyapatite with geometrically feasible ad nonfeasible structures: topology of osteogenesis10.1002/(SICI)1097-4636(199802)39:2<190::AID-JBM4>3.0.CO;2-K ↗
9. Osseointegrated implants in the treatment of the edentulous jaw. Experience from a 10-year period
10. Timing of loading and effect of micromotion on bone-dental implant interface: review of experimental literature10.1002/(SICI)1097-4636(199822)43:2<192::AID-JBM14>3.0.CO;2-K ↗
11. The future of biologic coatings for orthopaedic implants10.1016/j.biomaterials.2013.01.074 ↗
12. Osseointegration of dental implants in rabbit bone with low mineral density10.1016/S0278-2391(97)90124-5 ↗
13. Effects of steroid-induced osteoporosis on osseointegration of titanium implants
14. Effects of Ti ions and particles on neutrophil function and morphology10.1016/S0142-9612(02)00115-1 ↗
15. Titanium ion induces necrosis and sensitivity to lipopolysaccharide in gingival epithelial-like cells10.1016/j.tiv.2010.07.023 ↗
16. Stabilization of metallic supercooled liquid and bulk amorphous alloys10.1016/S1359-6454(99)00300-6 ↗
17. Difference in compressive and tensile fracture mechanisms of Zr59Cu20Al10Ni8Ti3 bulk metallic glass10.1016/S1359-6454(02)00521-9 ↗
18. Pitting corrosion of bulk glass-forming zirconium-based alloys10.1016/j.jallcom.2004.01.043 ↗
19. Zr-based bulk glassy alloy with improved resistance to stress corrosion cracking in sodium chloride solutions10.1016/j.corsci.2010.05.007 ↗
20. Effect of chloride ion concentration on the fatigue crack growth rate of a Zr55Al10Ni5Cu30 bulk metallic glass10.2320/matertrans.MRP2007085 ↗
21. Study of structural relaxation-induced embrittlement of hypoeutectic Zr-Cu-Al ternary bulk glassy alloys10.1016/j.actamat.2008.08.026 ↗
22. Malleable hypoeutectic Zr-Ni-Cu-Al bulk glassy alloys with tensile plastic elongation at room temperature10.1080/09500830902873575 ↗
23. Ni-free Zr-Cu-Al-Nb-Pd bulk metallic glasses with different Zr/Cu ratios for biomedical applications10.1002/jbm.b.32715 ↗
24. Physical and mechanical properties of Zr-based metallic glasses10.2320/matertrans1989.36.890 ↗
25. Longitudinal elastic properties and porosity of cortical bone tissue vary with age in human proximal femur10.1016/j.bone.2013.01.015 ↗
26. The corrosion behaviour of Zr-based bulk metallic glasses in 0.5 M NaCl solution10.1016/j.corsci.2011.05.014 ↗
27. Zr61Ti2Cu25Al12 metallic glass for potential use in dental implants: Biocompatibility assessment by in vitro cellular responses10.1016/j.msec.2013.01.033 ↗
28. Development of an automatic fabrication system for cast glassy alloys10.1007/s11663-014-0282-x ↗
29. Pseudo float melting state in ladle arc-melt-type furnace for preparing crystalline inclusion-free bulk amorphous alloy10.2320/matertrans.43.2316 ↗
30. New method of thread rolling10.1016/j.jmatprotec.2004.04.154 ↗
31. Tough hypoeutectic Zr-based bulk metallic glasses10.1007/s11661-011-0631-1 ↗
32. Identification and characterization of the new osteoclast progenitor with macrophage phenotypes being able to differentiate into mature osteoclasts10.1359/jbmr.2000.15.8.1477 ↗
33. Orthodontic mini-implant stability and the ratio of pilot hole implant diameter10.1093/ejo/cjq157 ↗
34. Primary stability and histomorphometric bone-implant contact of self-drilling and self-tapping orthodontic microimplants10.1016/j.ajodo.2011.07.020 ↗
35. Effects of TiO2 nanotubes with different diameters on gene expression and osseointegration of implants in minipigs10.1016/j.biomaterials.2011.06.023 ↗
36. Titanium alloy mini-implants for orthodontic anchorage: Immediate loading and metal ion release10.1016/j.actbio.2006.10.010 ↗
37. Isolation and characterization of osteoblast precursor cells from human bone marrow10.1002/jbmr.5650110305 ↗
38. In vitro study on Zr-based bulk metallic glasses as potential biomaterials10.1002/jbm.b.31725 ↗
39. Multiscale analyses of the bone-implant interface10.1177/0022034514566029 ↗
40. The effect of static bone strain on implant stability and bone remodeling10.1016/j.bone.2011.07.003 ↗
41. Orthodontic mini-implant stability in different healing times before loading: a microscopic computerized tomographic and biomechanical analysis10.1016/j.tripleo.2009.03.023 ↗
42. The use of small titanium screws for orthodontic anchorage10.1177/154405910308200510 ↗
43. In vivo evaluation of Zr-based bulk metallic glass alloy intramedullary nails in rat femora10.1007/s10856-013-5102-3 ↗
44. Biomechanics and load resistance of small-diameter and mini dental implants: a review of literature10.1515/bmt-2013-0092 ↗
45. Effect of mini-implant diameter on fracture risk and self-drilling efficacy10.1016/j.ajodo.2011.06.016 ↗
46. Bone loss and reduced bone quality of the human femur after total hip arthroplasty under stress-shielding effects by titanium-based implant10.2320/matertrans.M2011358 ↗
47. Numerical study of effect of elastomeric stress absorbers on stress reduction in bone-dental implant interface10.1590/1678-775720140086 ↗
48. Clinical efficacy of early loading versus conventional loading of dental implants10.1038/srep15995 ↗
49. Clinical efficacy of immediate implant loading protocols compared to conventional loading depending on the type of the restoration: a systematic review10.1111/clr.12428 ↗
50. Effect of mechanical stimuli on skeletal regeneration around implants10.1016/j.bone.2006.10.027 ↗
51. Enhancement of implant osseointegration by high-frequency low-magnitude loading10.1371/journal.pone.0040488 ↗
52. Control of osteoblast function and regulation of bone mass10.1038/nature01660 ↗
53. Bone resorption by osteoclasts10.1126/science.289.5484.1504 ↗
54. Effect of parathyroid hormone (1–34) on fractures and bone mineral density in postmenopausal women with osteoporosis10.1056/NEJM200105103441904 ↗
55. Evidence that intermittent treatment with parathyroid hormone increases bone formation in adult rats by activation of bone lining cells10.1210/endo.136.8.7628403 ↗
56. The anabolic effect of human PTH (1–34) on bone formation is blunted when bone resorption is inhibited by the bisphosphonate tiludronate – is activated resorption a prerequisite for the in vivo effect of PTH on formation in a remodeling system10.1016/8756-3282(95)00113-R ↗
57. Parathyroid hormone is more effective than estrogen or bisphosphonates for restoration of lost bone mass in ovariectomized rats10.1210/endo.132.2.8425497 ↗
58. Special modes of corrosion under physiological and simulated physiological conditions10.1016/j.actbio.2007.12.003 ↗
59. Changes of concentrations of the elements Co, Cr, Sb, and Sc in tissues of persons with joint implants10.1007/BF02917340 ↗
60. Influence on elementalstatus by hip-endoprostheses10.1016/j.microc.2006.04.019 ↗
61. Immunologic mechanisms in hypersensitivity reactions to metal ions: an overview10.1034/j.1398-9995.2000.00107.x ↗
62. Allergy-inducing nickel concentration is lowered by lipopolysaccharide at both the sensitization and elicitation steps in a murine model10.1111/j.1365-2133.2010.10016.x ↗
63. Quantitative aspects of nickel dermatitis. Sensitization and eliciting threshold concentrations10.1016/0048-9697(94)90403-0 ↗
64. Aluminum in the diet and Alzheimer’s disease: from current epidemiology to possible disease-modifying treatment10.3233/JAD-2010-1340 ↗
65. Selective accumulation of aluminum in cerebral arteries in Alzheimer's disease (AD)10.1016/j.jinorgbio.2013.05.007 ↗
66. Chronic toxicity of aluminium in rats and mice and its effects on phosphorus metabolism
67. Accumulation of aluminum in rat brain: does it lead to behavioral and electrophysiological changes ?10.1385/BTER:92:3:231 ↗
68. Determination of lead, copper and iron in cosmetics, water, soil and food using polyhydroxybutyrate-B-polydimethylsiloxane preconcentration and flame atomic absorption spectroscopy10.1080/00032719.2014.971365 ↗
69. Trace elements in human physiology and pathology10.1016/S0753-3322(03)00012-X ↗
70. Activation of Erk and p53 regulates copper oxide nanoparticle-induced cytotoxicity in keratinocytes and fibroblasts10.2147/IJN.S67688 ↗