journal article·2017-09

Anodic bonding of titanium alloy with bioactive glass

Eduardo Mioduski Szesz, Carlos Mauricio Lepienski

Publisher page

Abstract

Abstract The aim of this paper is to report the use of the anodic bonding technique to bond titanium alloy and two different bioactive glasses aiming the medical application of these biomaterials. Ti alloy and bioactive glasses 52S4.6 and 45S5 were successfully bonded using anodic bonding technique for range of temperature and applied potential. The effects of anodic bonding parameters over the total charge transferred and the bonding time were evaluated. The adhesion of Ti alloy and bioactive glasses was measured by shear test. Due to polishing process, titanium alloy samples shown a slightly rounding and consequently the bonding area was limited to part of the sample area. It was found the temperature and potential have effect with statistical significance over the total transferred charge and the bonding time. The results herein discussed suggest the viability of anodic bonding added to process versatility and material compatibility for the use of bioglass and Ti alloy bonded together on medical application.
Source: openaire · Quality: candidate unverified · Source record ↗

Research context

OpenAlex topics: Bone Tissue Engineering Materials · Dental materials and restorations · Dental Implant Techniques and Outcomes

SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.

References (33)

Show source-provided references
1. The story of bioglass10.1007/s10856-006-0432-z ↗
2. Adhesion of bioactive glass coating to Ti6Al4V oral implant10.1016/S0142-9612(00)00027-2 ↗
3. Bioactive glass nanopowder and bioglass coating for biocompatibility improvement of metallic implant10.1016/j.jmatprotec.2008.03.051 ↗
4. Pulsed laser deposition and in vitro characteristics of triphasic - HASi composition on titanium10.1177/0885328213484545 ↗
5. Bioactive glass coatings: a review10.1179/1743294410Y.0000000008 ↗
6. Novel resorbable glass-ceramic scaffolds for hard tissue engineering: from the parent phosphate glass to its bone-like macroporous derivatives10.1177/0885328213506759 ↗
7. Evaluation of borate bioactive glass scaffolds with different pore sizes in a rat subcutaneous implantation model10.1177/0885328212470013 ↗
8. Surface modification of titanium, titanium alloys, and related materials for biomedical applications10.1016/j.mser.2004.11.001 ↗
9. Ti based biomaterials, the ultimate choice for orthopaedic implants – a review10.1016/j.pmatsci.2008.06.004 ↗
10. The effect of bond coat on mechanical properties of plasma sprayed bioglass-titanium coatings10.1016/S0272-8842(03)00107-X ↗
12. Field assisted glass-metal sealing10.1063/1.1657121 ↗
13. Wafer-scale titanium anodic bonding for microfluidic applications10.1016/j.snb.2014.08.083 ↗
14. Initiation toughness of silicon/glass anodic bonds10.1016/S1359-6454(99)00352-3 ↗
15. An experimental fracture mechanics study of a strong interface: the silicon/glass anodic bond10.1557/JMR.1995.0387 ↗
16. Bioactive glasses
17. An improved anodic bonding process using pulsed voltage technique10.1109/84.896767 ↗
18. Electrode phenomena during anodic bonding of silicon to sodium borosilicate glass10.1149/1.2085374 ↗
19. How useful is SBF in predicting in vivo bone bioactivity?10.1016/j.biomaterials.2006.01.017 ↗
20. Direct-current polarization during field-assisted glass-metal sealing10.1111/j.1151-2916.1970.tb15967.x ↗
21. Raman spectroscopic study of bioactive silica based glasses10.1016/S0022-3093(03)00013-9 ↗
22. Raman spectroscopic study of bioactive silica-based glasses: the role of the alkali/alkali earth ratio on the non-bridging oxygen/bridging oxygen (NBO/BO) ratio10.1155/2009/418698 ↗
23. In situ Raman spectroscopy investigation of bioactive glass reactivity: simulated body fluid solution vs TRIS-buffered solution10.1016/j.matchar.2011.07.008 ↗
24. Rate processes during anodic bonding10.1111/j.1151-2916.1992.tb05483.x ↗
25. Dziuban · 2006
26. Interpretation of electrical polarization and depolarization mechanisms of bioactive glasses in relation to ionic migration10.1016/j.biomaterials.2003.12.028 ↗
27. In situ investigation of ion drift processes in glass during anodic bonding10.1016/S0924-4247(97)01768-8 ↗
28. Electric field distribution ons near-surface modifications in soda-lime glass submitted to a dc potential10.1016/0022-3093(93)90224-L ↗
29. Anodic oxidation during electrostatic bonding10.1080/14786430310001637015 ↗
30. Anodic bonding of imperfect surfaces10.1063/1.332357 ↗
31. Na2CaSi2O6–P2O5 based bioactive glasses. Part 1: Elasticity and structure10.1016/j.jnoncrysol.2005.08.020 ↗
32. The power of databases: the RRUFF project
33. Carbonate assignment and calibration in the Raman Spectrum of apatite10.1007/s00223-007-9034-0 ↗