journal article·2018-04

Enhanced tendon-to-bone repair through adhesive films

Stephen W. Linderman, Mikhail Golman, Thomas R. Gardner, Victor Birman, William N. Levine, Guy M. Genin, Stavros Thomopoulos

Acta Biomaterialia· Volume 70
Publisher page

Abstract

Tendon-to-bone surgical repairs have unacceptably high failure rates, possibly due to their inability to recreate the load transfer mechanisms of the native enthesis. Instead of distributing load across a wide attachment footprint area, surgical repairs concentrate shear stress on a small number of suture anchor points. This motivates development of technologies that distribute shear stresses away from suture anchors and across the enthesis footprint. Here, we present predictions and proof-of-concept experiments showing that mechanically-optimized adhesive films can mimic the natural load transfer mechanisms of the healthy attachment and increase the load tolerance of a repair. Mechanical optimization, based upon a shear lag model corroborated by a finite element analysis, revealed that adhesives with relatively high strength and low stiffness can, theoretically, strengthen tendon-to-bone repairs by over 10-fold. Lap shear testing using tendon and bone planks validated the mechanical models for a range of adhesive stiffnesses and strengths. Ex vivo human supraspinatus repairs of cadaveric tissues using multipartite adhesives showed substantial increase in strength. Results suggest that adhesive-enhanced repair can improve repair strength, and motivate a search for optimal adhesives. Statement of significance Current surgical techniques for tendon-to-bone repair have unacceptably high failure rates, indicating that the initial repair strength is insufficient to prevent gapping or rupture. In the rotator cuff, repair techniques apply compression over the repair interface to achieve contact healing between tendon and bone, but transfer almost all force in shear across only a few points where sutures puncture the tendon. Therefore, we evaluated the ability of an adhesive film, implanted between tendon and bone, to enhance repair strength and minimize the likelihood of rupture. Mechanical models demonstrated that optimally designed adhesives would improve repair strength by over 10-fold. Experiments using idealized and clinically-relevant repairs validated these models. This work demonstrates an opportunity to dramatically improve tendon-to-bone repair strength using adhesive films with appropriate material properties.
Source: europepmc · Quality: candidate unverified · Source record ↗

Research context

OpenAlex topics: Shoulder Injury and Treatment · Tendon Structure and Treatment · Orthopedic Surgery and Rehabilitation

SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.

References (73)

Show source-provided references
1. Thomopoulos · 2013
2. Variation of biomechanical, structural, and compositional properties along the tendon to bone insertion site10.1016/S0736-0266(03)0057-3 ↗
3. Functional grading of mineral and collagen in the attachment of tendon to bone10.1016/j.bpj.2009.05.043 ↗
4. Modelling the mechanics of partially mineralized collagen fibrils, fibres and tissue10.1098/rsif.2013.0835 ↗
5. Bi-material attachment through a compliant interfacial system at the tendon-to-bone insertion site10.1016/j.mechmat.2011.08.005 ↗
6. Stochastic interdigitation as a toughening mechanism at the interface between tendon and bone10.1016/j.bpj.2014.09.049 ↗
7. The outcome and repair integrity of completely arthroscopically repaired large and massive rotator cuff tears10.2106/00004623-200402000-00002 ↗
8. Repairs of the rotator cuff. Correlation of functional results with integrity of the cuff10.2106/00004623-199173070-00004 ↗
9. Part I: footprint contact characteristics for a transosseous-equivalent rotator cuff repair technique compared with a double-row repair technique10.1016/j.jse.2006.09.010 ↗
10. Arthroscopic rotator cuff repair using a suture bridge technique: is the repair integrity actually maintained?10.1177/0363546510397171 ↗
11. Mode of failure for rotator cuff repair with suture anchors identified at revision surgery10.1067/mse.2003.21 ↗
12. New guideline on rotator cuff problems
13. Shear lag sutures: improved suture repair through the use of adhesives10.1016/j.actbio.2015.05.002 ↗
14. Double-row athroscopic rotator cuff repair: re-establishing the footprint of the rotator cuff10.1016/j.arthro.2003.09.036 ↗
15. Die nietkraftverteilung in zugbeanspruchten nievtverbindungen mit konstanten laschenquerschnitten
16. The elasticity and strength of paper and other fibrous materials10.1088/0508-3443/3/3/302 ↗
17. Adhesion and tack of polymers: influence of mechanical properties and surface tensions10.1007/BF01421887 ↗
18. Humeral insertion of the supraspinatus and infraspinatus: new anatomical findings regarding the footprint of the rotator cuff10.2106/JBJS.G.00427 ↗
19. Young’s modulus of trabecular and cortical bone material: ultrasonic and microtensile measurements10.1016/0021-9290(93)90042-D ↗
20. Mechanical properties of the long-head of the biceps tendon are altered in the presence of rotator cuff tears in a rat model10.1002/jor.20770 ↗
21. The tendon-to-bone attachment: unification through disarray10.1038/nmat4906 ↗
22. D.A. Dillard, Fundamentals of stress transfer in bonded systems. Adhesion science and engineering/series editor, A.V. Pocius, first ed., Elsevier, Amsterdam, The Netherlands, 2002.10.1016/B978-0-444-51140-9.50028-7 ↗
23. Different regions of bovine deep digital flexor tendon exhibit distinct elastic, but not viscous, mechanical properties under both compression and shear loading10.1016/j.jbiomech.2014.07.026 ↗
24. Henkel Corporation, 2014;Technical Data Sheet: Loctite 4903. URL: https://tds.us.henkel.com/NA/UT/HNAUTTDS.nsf/web/0192ED8CF7AABF1685257CF50048CB6A/$File/4903-EN.pdf, URL Accessed: 03/25/2015.
25. Effect of bone morphogenetic protein 2 on tendon-to-bone healing in a canine flexor tendon model10.1002/jor.22151 ↗
26. Early healing of flexor tendon insertion site injuries: tunnel repair is mechanically and histologically inferior to surface repair in a canine model10.1002/jor.20084 ↗
27. Use of a magnesium-based bone adhesive for flexor tendon-to-bone healing10.1016/j.jhsa.2009.04.018 ↗
28. The early effects of sustained platelet-derived functional and structural properties of repaired intrasynovial flexor tendons: an in vivo biomechanic study at 3 weeks in canines10.1016/j.jhsa.2006.12.009 ↗
29. The insertion site of the canine flexor digitorum profundus tendon heals slowly following injury and structure repair10.1016/S0736-0266(01)00139-5 ↗
30. Relationship between joint motion and flexor tendon force in the canine forelimb10.1016/S0363-5023(96)80299-1 ↗
31. Wrist and digital joint motion produce unique flexor tendon force and excursion in the canine forelimb10.1016/S0021-9290(98)00154-7 ↗
32. Optimal internal fixation of anatomically shaped synthetic bone grafts for massive segmental defects of long bones10.1016/j.clinbiomech.2015.08.016 ↗
33. Mechanical strength of repairs of the rotator cuff10.1302/0301-620X.76B3.8175836 ↗
34. Does double-row rotator cuff repair improve functional outcome of patients compared with single-row technique? A systematic review10.1177/0363546511428866 ↗
35. Advances in biologic augmentation for rotator cuff repair10.1111/nyas.13267 ↗
36. The mechanical properties of natural materials. I. Material property charts
37. Overview no. 80: on the engineering properties of materials10.1016/0001-6160(89)90158-2 ↗
38. The mechanical efficiency of natural materials10.1080/14786430410001680935 ↗
39. Part II: biomechanical assessment for a footprint-restoring transosseous-equivalent rotator cuff repair technique compared with a double-row repair technique10.1016/j.jse.2006.09.011 ↗
40. Retear rates after arthroscopic single-row, double-row, and suture bridge rotator cuff repair at a minimum of 1 year of imaging follow-up: a systematic review10.1016/j.arthro.2015.06.004 ↗
41. On the use of shear-lag methods for analysis of stress transfer in unidirectional composites10.1016/S0167-6636(97)00023-9 ↗
42. A review of natural joint systems and numerical investigation of bio-inspired GFRP-to-steel joints10.3390/ma9070566 ↗
43. Biomimetic-inspired CFRP to perforated steel joints10.1016/j.compstruct.2016.06.014 ↗
44. Simple and accurate methods for quantifying deformation, disruption, and development in biological tissues10.1098/rsif.2014.0685 ↗
45. Bonded-bolted composite joints10.2514/3.45237 ↗
46. Load transfer in hybrid (bonded/bolted) composite single-lap joints10.1016/j.compstruct.2004.04.016 ↗
47. Static strength of a composite butt joint configuration with different attachments10.1016/j.compstruct.2011.12.008 ↗
48. Experimental and finite element studies of bolted, bonded and hybrid step lap joints of thick carbon fibre/epoxy panels used in aircraft structures10.1016/j.compositesb.2016.06.061 ↗
49. Frog glue enhances rotator cuff repair in a laboratory cadaveric model10.1016/j.jse.2008.12.007 ↗
50. Characterization of a protein-based adhesive elastomer secreted by the Australian frog Notaden bennetti10.1021/bm050335e ↗
51. L.D. Graham, V. Glattauer, P.R. Vaughan, J.A. Werkmeister, M.J. Tyler, J.A. Ramshaw, et al., An adhesive secreted by Australian frogs of the genus Notaden, in: Biological Adhesives, Springer; 2006, pp. 207–223.10.1007/978-3-540-31049-5_11 ↗
52. Bioresorbable bone adhesives. Historical perspective and current status
53. Integrating soft and hard tissues via interface tissue engineering
54. Adhesive-enhanced sternal closure: feasibility and safety of late sternal reentry
55. Adhesives based on butyl-cyanoacrylate for fixation of autologous bone graft: pilot study in rabbits10.1111/edt.12328 ↗
56. Septal deviation treatment using bone or cartilage grafts fixed with cyanoacrylate tissue adhesive
57. Healing at the interface between autologous block bone grafts and recipient sites using n-butyl-2-cyanoacrylate as fixation. Histomorphometric study in rabbits10.1563/aaid-joi-D-17-00108 ↗
58. Efficacy and safety of using n-butyl cyanoacrylate in cranial fixation following trauma and other pathologies10.5137/1019-5149.JTN.20117-17.1 ↗
59. Effects of different tissue adhesives in treating calvarial bone defects10.1097/SCS.0000000000003833 ↗
60. Development of a bioresorbable self-hardening bone adhesive based on a composite consisting of polylactide methacrylates and β-tricalcium phosphate10.1002/jbm.b.31252 ↗
61. Bond strength of an alkylene bis (dilactoyl)-methacrylate bone adhesive: a biomechanical evaluation in sheep10.1163/092050609X12517190417759 ↗
62. The tissue response to an alkylene bis (dilactoyl)-methacrylate bone adhesive10.1016/j.biomaterials.2004.04.048 ↗
63. Adhesive strength of a β-tricalcium phosphate-enriched bone adhesive10.1055/s-0030-1270709 ↗
64. A review of fibrin and fibrin composites for bone tissue engineering10.2147/IJN.S124671 ↗
65. An overview on autologous fibrin glue in bone tissue engineering of maxillofacial surgery10.4103/1735-3327.205789 ↗
66. Underwater contact adhesion and microarchitecture in polyelectrolyte complexes actuated by solvent exchange10.1038/nmat4539 ↗
67. Tough adhesives for diverse wet surfaces10.1126/science.aah6362 ↗
68. Mussel-inspired nano-building block assemblies for mimicking extracellular matrix microenvironments with multiple functions10.1088/1758-5090/aa7fdc ↗
69. Mussel-inspired thermo-responsive polypeptide-pluronic copolymers for versatile surgical adhesives and hemostasis
70. BMP-2 immobilized PLGA/hydroxyapatite fibrous scaffold via polydopamine stimulates osteoblast growth10.1016/j.msec.2017.03.186 ↗
71. Poly (lactic acid) blends with poly (trimethylene carbonate) as biodegradable medical adhesive material10.3390/ijms18102041 ↗
72. Mineral trioxide aggregate improves healing response of periodontal tissue to injury in mice10.1111/jre.12478 ↗
73. Sandwich-type PLLA-nanosheets loaded with BMP-2 induce bone regeneration in critical-sized mouse calvarial defects10.1016/j.actbio.2017.06.041 ↗