journal article·2022-04Open access

A high-accuracy and high-efficiency digital volume correlation method to characterize in-vivo optic nerve head biomechanics from optical coherence tomography

Fuqiang Zhong, Bingrui Wang, Junchao Wei, Yi Hua, Bo Wang, Juan Reynaud, Brad Fortune, Ian A. Sigal

Acta Biomaterialia· Volume 143

Abstract

In-vivo optic nerve head (ONH) biomechanics characterization is emerging as a promising way to study eye physiology and pathology. We propose a high-accuracy and high-efficiency digital volume correlation (DVC) method to characterize the in-vivo ONH deformation from optical coherence tomography (OCT) volumes. Using a combination of synthetic tests and analysis of OCTs from monkey ONHs subjected to acutely elevated intraocular pressure, we demonstrate that our proposed methodology overcame several challenges for conventional DVC methods: First, a pre-registration technique was used to remove large ONH rigid body motion in OCT volumes which could lead to analysis failure; second, a modified 3D inverse-compositional Gaussian Newton method was used to ensure sub-voxel accuracy of displacement calculations despite high noise and low image contrast of some OCT volumes; third, a tricubic B-spline interpolation method was applied to improve computational efficiency; fourth, a confidence parameter was introduced to guide the searching path in the displacement calculation; fifth, a confidence-weighted strain calculation method was applied to further improve the accuracy. The proposed DVC method had displacement errors smaller than 0.037 and 0.028 voxels with Gaussian and speckle noises, respectively. The strain errors in the three directions were less than 0.0045 and 0.0018 with Gaussian and speckle noises, respectively. Compared with the conventional DVC method, the proposed method reduced the errors of displacement and strain calculations by up to 70% under large body motions, with 75% lower computation time, while saving about 30% memory. Our study demonstrates the potential of the proposed technique to investigate ONH biomechanics. STATEMENT OF SIGNIFICANCE: The biomechanics of the optic nerve head (ONH) in the posterior pole of the globe play a central role in eye physiology and pathology. The application of digital volume correlation (DVC) to the analysis of optical coherence tomography (OCT) images of the ONH has emerged as a promising way to quantify ONH biomechanics. Conventional DVC methods, however, face several important challenges when analyzing OCT images of the ONH. We introduce a high-accuracy and high-efficiency DVC method to characterize in vivo ONH deformations from OCT volumes. We demonstrate the new method using synthetic tests and actual OCT data from monkey ONHs. The new method also has the potential to be used to study other tissues, as OCT applications continue to expand.
Source: europepmc · Quality: candidate unverified · Source record ↗

Research context

OpenAlex topics: Glaucoma and retinal disorders · Corneal surgery and disorders · Optical Coherence Tomography Applications

SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.

References (52)

Show source-provided references
1. Biomechanics of the posterior eye: a critical role in health and disease10.1115/1.4026286 ↗
2. IOP-induced regional displacements in the optic nerve head and correlation with peripapillary sclera thickness10.1016/j.exer.2020.108202 ↗
3. Morphologic changes in the lamina cribrosa correlated with neural loss in open-angle glaucoma10.1016/0002-9394(83)90389-6 ↗
4. The optic nerve head as a biomechanical structure: a new paradigm for understanding the role of IOP-related stress and strain in the pathophysiology of glaucomatous optic nerve head damage10.1016/j.preteyeres.2004.06.001 ↗
5. Glaucomatous cupping of the lamina cribrosa: a review of the evidence for active progressive remodeling as a mechanism10.1016/j.exer.2010.08.004 ↗
6. The pressure-induced deformation response of the human lamina cribrosa: analysis of regional variations10.1016/j.actbio.2016.12.054 ↗
7. In vivo optic nerve head biomechanics: performance testing of a three-dimensional tracking algorithm10.1098/rsif.2013.0459 ↗
8. Recent advances in OCT imaging of the lamina cribrosa10.1136/bjophthalmol-2013-304751 ↗
9. Reproducibility of in-vivo OCT measured three-dimensional human lamina cribrosa microarchitecture10.1371/journal.pone.0095526 ↗
10. Peripheral lamina cribrosa depth in primary open-angle glaucoma: a swept-source optical coherence tomography study of lamina cribrosa10.1038/eye.2015.162 ↗
11. Optic nerve head deformation in glaucoma: a prospective analysis of optic nerve head surface and lamina cribrosa surface displacement10.1016/j.ophtha.2015.02.035 ↗
12. Displacement of the lamina cribrosa in response to acute intraocular pressure elevation in normal individuals of African and European descent10.1167/iovs.15-17940 ↗
13. In vivo detection of laminar and peripapillary scleral hypercompliance in early monkey experimental glaucoma10.1167/iovs.15-18666 ↗
14. Optic nerve tissue displacement during mild intraocular pressure elevation: its relationship to central corneal thickness and corneal hysteresis10.1111/opo.12568 ↗
15. Changes in the anterior lamina cribrosa morphology with glaucoma severity
16. Lamina cribrosa moves anteriorly after trabeculectomy in myopic eyes10.1167/iovs.61.6.36 ↗
17. Relationship of corneal hysteresis and anterior lamina cribrosa displacement in glaucoma10.1016/j.ajo.2019.11.017 ↗
18. Laminar and prelaminar tissue displacement during intraocular pressure elevation in glaucoma patients and healthy controls10.1016/j.ophtha.2010.05.016 ↗
19. Racial differences in the association of anterior lamina cribrosa surface depth and glaucoma severity in the African Descent and Glaucoma Evaluation Study (ADAGES)10.1167/iovs.19-26645 ↗
20. Some recent advances in digital volume correlation10.1016/j.optlaseng.2020.106189 ↗
21. Eye-specific IOP-induced displacements and deformations of human lamina cribrosa10.1167/iovs.13-12724 ↗
22. In vivo 3-dimensional strain mapping confirms large optic nerve head deformations following horizontal eye movements10.1167/iovs.16-20560 ↗
23. Gaze-evoked deformations in optic nerve head drusen
24. In-vivo effects of intraocular and intracranial pressures on the lamina cribrosa microstructure10.1371/journal.pone.0188302 ↗
25. In vivo optic nerve head mechanical response to intraocular and cerebrospinal fluid pressure: imaging protocol and quantification method10.1038/s41598-018-31052-x ↗
26. In vivo characterization of the deformation of the human optic nerve head using optical coherence tomography and digital volume correlation10.1016/j.actbio.2019.06.050 ↗
27. Biomechanics of the optic nerve head and peripapillary sclera in a mouse model of glaucoma10.1098/rsif.2020.0708 ↗
28. Histologic validation of optical coherence tomography-based three-dimensional morphometric measurements of the human optic nerve head: methodology and preliminary results10.1016/j.exer.2021.108475 ↗
29. Digital image correlation in polar coordinate robust to a large rotation10.1016/j.optlaseng.2017.06.019 ↗
30. GPU accelerated digital volume correlation10.1007/s11340-015-0091-4 ↗
31. Measuring in-vivo and in-situ ex-vivo the 3D deformation of the lamina cribrosa microstructure under elevated intraocular pressure
32. An efficient and accurate 3D displacements tracking strategy for digital volume correlation10.1016/j.optlaseng.2014.02.003 ↗
33. Onset and progression of peripapillary retinal nerve fiber layer (RNFL) retardance changes occur earlier than RNFL thickness changes in experimental glaucoma10.1167/iovs.13-12219 ↗
34. A problem of proportions in OCT-based morphometry and a proposed solution10.1167/iovs.15-18570 ↗
35. An FFT-based technique for translation, rotation, and scale-invariant image registration10.1109/83.506761 ↗
36. Three-dimensional static optical coherence elastography based on inverse compositional Gauss-Newton digital volume correlation10.1002/jbio.201800422 ↗
37. A flexible and accurate digital volume correlation method applicable to high-resolution volumetric images10.1088/1361-6501/aa7e8a ↗
38. Accuracy enhancement of digital image correlation with B-spline interpolation10.1364/OL.36.003070 ↗
39. Mean intensity gradient: an effective global parameter for quality assessment of the speckle patterns used in digital image correlation10.1016/j.optlaseng.2009.08.010 ↗
40. Correction of rigid body motion in deformation measurement of rotating objects10.1016/j.measurement.2018.07.049 ↗
41. Speckle in optical coherence tomography: an overview, Saratov Fall Meeting'98: light Scattering Technologies for Mechanics
42. Internal displacement and strain measurement using digital volume correlation: a least-squares framework10.1088/0957-0233/23/4/045002 ↗
43. Mapping in-vivo optic nerve head strains caused by intraocular and intracranial pressures
44. A fast iterative digital volume correlation algorithm for large deformations10.1007/s11340-014-9874-2 ↗
45. Shadow removal and contrast enhancement in optical coherence tomography images of the human optic nerve head10.1167/iovs.10-6925 ↗
46. Lamina cribrosa visibility using optical coherence tomography: comparison of devices and effects of image enhancement techniques10.1167/iovs.14-14903 ↗
47. Niemeijer · 2009
48. In-vivo evidence of lamina cribrosa deformations induced by chronically elevated IOP in non-human primates
49. In-vivo evidence of increased lamina cribrosa compliance at onset of experimental glaucoma in nonhuman primates
50. Synchrotron tomography of intervertebral disc deformation quantified by digital volume correlation reveals microstructural influence on strain patterns10.1016/j.actbio.2019.05.021 ↗
51. Characterization of chemoelastic effects in arteries using digital volume correlation and optical coherence tomography10.1016/j.actbio.2019.11.049 ↗
52. The inflation response of the human lamina cribrosa and sclera: analysis of deformation and interaction10.1016/j.actbio.2020.01.049 ↗