journal article·2021-07

Effective easing of the side effects of copper intrauterine devices using ultra-fine-grained Cu-0.4Mg alloy

Qianqian Fan, Guo Bao, Dongfeng Ge, Kun Wang, Mingming Sun, Tingting Liu, Jianing Liu, Zechuan Zhang, Xiangbo Xu, Xiaoxue Xu, Bin He, Jiancun Rao, Yufeng Zheng

Acta Biomaterialia· Volume 128
Publisher page

Abstract

Copper intrauterine device is one of the most adopted contraceptive methods with high effectiveness (over 99 %), low cost, spontaneous reversibility and long-lasting usage. However, the side effects induced from the initial burst release of copper ions (Cu2+) hinder the continuation of the Cu-IUD made of Coarse-Grained Copper (CG Cu). We proposed to tailor the bio-corrosion behaviors of better control of Cu2+ release via the addition of bioactive Mg into the Ultra-Fine Grained (UFG) Bulk Cu. Thus, UFG bulk Cu with 0.4 wt.% Mg was produced via equal-channel angular pressing. The microstructures of the UFG Cu-0.4Mg was observed using electron backscatter diffraction and transmission electron microscopy techniques. The in vitro long-term corrosion behaviors in simulated uterine fluid, cytotoxicity to four cell lines, in vivo biocompatibility and contraceptive efficacy were all studied on CG Cu, UFG Cu and UFG Cu-0.4Mg materials. The results demonstrate that both the ultrafine grains and the addition of bioactive Mg into Cu contribute to the suppression of the burst release of Cu2+ in the initial stage and the maintenance of high level Cu2+ in long-term release. Moreover, the UFG Cu-0.4Mg also exhibited much improved cell and tissue biocompatibility from both the in vitro and in vivo evaluations. Therefore, the contraceptive efficacy of UFG Cu-0.4Mg is still maintained as high as the CG Cu and UFG Cu while the side effects are significantly eased, suggesting the high potential of the UFG Cu-0.4Mg alloy as a new upgrading or alternative material for Cu-IUD. STATEMENT OF SIGNIFICANCE: The side effects from burst release of Cu2+ at the initial implantation stage of Cu-containing intrauterine devices (Cu-IUD) is one of the main drawbacks of these devices. In this work, an ultra-fine-grained Cu (UFG Cu) alloyed with a low amount of bioactive Mg was used for a Cu-IUD. The UFG Cu-0.4Mg alloy exhibited suppressed burst release of Cu2+ at initial implantation, while active Cu2+ release for long-term usage was maintained, comparable to coarse-grained pure Cu. Furthermore, the UFG Cu-0.4Mg alloy displayed significantly improved biocompatibility with human uterus cells and a much decreased inflammatory response within the uterus. Therefore, the side effects from Cu-IUD were eased, while high antifertility efficacy of the UFG Cu-0.4Mg alloy was maintained. The UFG Cu-0.4Mg alloy is promising for Cu-IUD.
Source: europepmc · Quality: candidate unverified · Source record ↗

Research context

OpenAlex topics: Magnesium Alloys: Properties and Applications · Orthopaedic implants and arthroplasty

SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.

References (73)

Show source-provided references
1. Corrosion of copper intrauterine devices: review and recent developments10.1515/corrrev-2019-0012 ↗
2. Long-acting reversible contraception10.1056/NEJMcp1608736 ↗
3. Intrauterine devices and contraceptive implants: overview of options and updates on method use10.1007/s13669-017-0200-8 ↗
4. Hormonal and intrauterine methods for contraception for women aged 25 years and younger
5. Copper-T intrauterine device and levonorgestrel intrauterine system: biological bases of their mechanism of action10.1016/j.contraception.2007.01.020 ↗
6. Release behavior of cupric ions for TCu380A and TCu220C IUDs10.1088/1748-6041/3/4/044114 ↗
7. Copper containing, framed intra-uterine devices for contraception
8. Relationship between copper IUD complications and ultrasonographic findings10.1007/s00404-018-4711-y ↗
9. Analysis of the reason of abnormal uterine bleeding induced by copper corrosion of IUD Cu10.12891/ceog3204.2016 ↗
10. Temporal trends of copper-bearing intrauterine device discontinuation: a population-based birth-cohort study of contraceptive use among rural married women in China10.1177/1010539513517259 ↗
11. Effects of copper and zinc on rat uterine muscle contraction and rabbit blastocyst fluid accumulation10.1095/biolreprod25.3.502 ↗
12. Discontinuation rates and acceptability during 1 year of using the intrauterine ball (the SCu380A)10.1016/j.contraception.2015.12.002 ↗
13. Reduction of the "burst release" of copper ions from copper-based intrauterine devices by organic inhibitors10.1016/j.contraception.2011.05.011 ↗
14. Decrease in cytotoxicity of copper-based intrauterine devices (IUD) pretreated with 6-mercaptopurine and pterin as biocompatible corrosion inhibitors10.1021/am3025307 ↗
15. Corrosion behavior of Cu and the Cu-Zn-Al shape memory alloy in simulated uterine fluid10.1016/j.contraception.2005.04.006 ↗
16. A porous Cu/LDPE composite for copper-containing intrauterine contraceptive devices10.1016/j.actbio.2011.09.024 ↗
17. Corrosion behavior of copper/LDPE nanocomposites in simulated uterine solution10.1016/j.biomaterials.2004.08.003 ↗
18. Biological evaluation of a novel copper-containing composite for contraception10.1016/j.fertnstert.2010.04.041 ↗
19. Zn(2+) release behavior and surface characteristics of Zn/LDPE nanocomposites and ZnO/LDPE nanocomposites in simulated uterine solution10.1007/s10856-008-3467-5 ↗
20. Zn2+ release from zinc and zinc oxide particles in simulated uterine solution10.1016/j.colsurfb.2005.12.007 ↗
21. Effective inhibition of the early copper ion burst release with ultra-fine grained copper and single crystal copper for intrauterine device application10.1016/j.actbio.2011.10.018 ↗
22. Corrosion and ion release behavior of ultra-fine grained bulk pure copper fabricated by ECAP in Hanks solution as potential biomaterial for contraception10.1016/j.matlet.2009.11.065 ↗
23. Biological response of chemically treated surface of the ultrafine-grained Ti-6Al-7Nb alloy for biomedical applications10.2147/IJN.S197099 ↗
24. Ultrafine grained titanium for biomedical applications: an overview of performance10.1016/j.jmrt.2013.07.003 ↗
25. Cellular response of preosteoblasts to nanograined/ultrafine-grained structures10.1016/j.actbio.2008.12.017 ↗
26. In vitro biocompatibility of an ultrafine grained zirconium10.1016/j.biomaterials.2007.06.015 ↗
27. Ultra-fine grained degradable magnesium for biomedical applications10.1016/S1875-5372(15)60001-7 ↗
28. Review of magnesium-based biomaterials and their applications10.1016/j.jma.2018.02.003 ↗
29. Role of cellular magnesium in health and human disease10.2741/1223 ↗
30. Magnesium and inflammation: advances and perspectives
31. Intravenous magnesium sulfate in the management of severe pre-eclampsia: a randomized study of 12-hour versus 24-hour maintenance dose10.1002/ijgo.13082 ↗
32. Risk factors for uterine atony/postpartum hemorrhage requiring treatment after vaginal delivery
33. Assessment of magnesium-based biomaterials: from bench to clinic10.1039/C9BM00289H ↗
34. Magnesium and its alloys as orthopedic biomaterials: a review10.1016/j.biomaterials.2005.10.003 ↗
35. Copper corrosion-simulated uterine solutions10.1016/S0010-7824(00)00124-4 ↗
36. 2004
37. In vitro and in vivo studies on magnesium alloys to evaluate the feasibility of their use in obstetrics and gynecology10.1016/j.actbio.2019.08.001 ↗
38. Magnesium-based sacrificial anode cathodic protection coatings (Mg-rich primers) for aluminum alloys10.3390/met2030353 ↗
39. Electrochemical stability of Cu–10Al–10Zn, Cu–10Al–10Ni, and Cu–10Ni–10Zn ternary alloys in simulated physiological solutions
40. Chronic systemic toxicity study of copper intrauterine devices in female Wistar rats10.12659/MSM.902137 ↗
41. Gold nanoshell nanomicelles for potential magnetic resonance imaging, light-triggered drug release, and photothermal therapy10.1002/adfm.201201663 ↗
42. Electrochemical behavior of mechanically alloyed hard Cu-Al alloys in marine environment10.1016/j.corsci.2019.03.043 ↗
43. Corrosion behavior of copper alloys in chloride media10.1016/j.matdes.2008.10.015 ↗
44. Effect of Ti content on corrosion behavior of Cu-Ti alloys in 3.5 % NaCl solution10.1016/S1003-6326(18)64699-0 ↗
45. The Cu-Mg (copper-magnesium) system10.1007/BF02868722 ↗
46. The development of binary Mg–Ca alloys for use as biodegradable materials within bone10.1016/j.biomaterials.2007.12.021 ↗
47. In vitro corrosion and biocompatibility of binary magnesium alloys10.1016/j.biomaterials.2008.10.021 ↗
48. Assessment of copper corrosion from frameless copper IUDs after long-term in utero residence10.1016/j.contraception.2014.05.009 ↗
49. Mechanisms of action of intrauterine devices: update and estimation of postfertilization effects10.1067/mob.2002.128091 ↗
50. Intrauterine devices: effective contraception with noncontraceptive benefits for adolescents10.1016/j.jpag.2019.07.001 ↗
51. Heavy metals and human spermatozoa. III. The toxicity of copper ions for spermatozoa10.1016/0010-7824(88)90050-9 ↗
52. Chemical reactions of the copper intrauterine device**supported by the ford foundation, grant 690010610.1016/S0015-0282(16)38703-9 ↗
53. Intrauterine devices: mechanisms of action, safety, and efficacy10.1016/S0010-7824(98)00082-1 ↗
54. Long-term safety, efficacy, and patient acceptability of the intrauterine copper T-380A contraceptive device10.2147/IJWH.S6914 ↗
55. Could the defects in the endometrial extracellular matrix during the implantation be a cause for impaired fertility?10.1111/j.1600-0897.2006.00443.x ↗
56. Alterations in the endometrium of rats, rabbits, and Macaca mulatta that received an implantation of copper/low-density polyethylene nanocomposite10.2147/IJN.S56756 ↗
57. The effect of copper on endometrial receptivity and induction of apoptosis on decidualized human endometrial stromal cells10.1177/1933719117732165 ↗
58. Effects of excess copper ions on decidualization of human endometrial stromal cells10.1007/s12011-016-0840-y ↗
59. Does over-exposure to copper ions released from metallic copper induce cytotoxic and genotoxic effects on mammalian cells?10.1016/j.contraception.2009.12.003 ↗
60. Bleeding, cramping, and satisfaction among new copper IUD users: a prospective study10.1371/journal.pone.0199724 ↗
61. In vitro cytotoxicity of Cu(2)(+), Zn(2)(+), Ag(+) and their mixtures on primary human endometrial epithelial cells10.1016/j.contraception.2011.09.016 ↗
62. Inflammatory cytokine profile of cocultivated primary cells from the endometrium of women with and without endometriosis
63. Correlative investigation of copper/low-density polyethylene nanocomposite on the endometrial angiogenesis in rats10.1007/s11684-007-0078-3 ↗
64. Changes in copper and zinc serum levels in women wearing a copper TCu-380A intrauterine device10.3109/13625187.2013.856404 ↗
65. Copper metallothioneins10.1002/iub.1618 ↗
66. Influence of magnesium substitution on a collagen–apatite biomaterial on the production of a calcifying matrix by human osteoblasts10.1002/(SICI)1097-4636(19981215)42:4<626::AID-JBM20>3.0.CO;2-S ↗
67. Novel magnesium alloys developed for biomedical application: a review10.1016/j.jmst.2013.02.005 ↗
68. Biodegradable Mg-Cu alloy implants with antibacterial activity for the treatment of osteomyelitis: in vitro and in vivo evaluations10.1016/j.biomaterials.2016.08.031 ↗
69. Magnesium sulfate infusion for acute asthma in the emergency department10.1016/j.jped.2017.06.002 ↗
70. Comparison of surface morphology and composition of intrauterine devices in relation to patient complaints10.1016/j.contraception.2004.03.006 ↗
71. Antifertility effectiveness of a novel copper-containing intrauterine device material and its influence on the endometrial environment in rats10.1016/j.msec.2018.04.025 ↗
72. The composition of rat uterine luminal fluid10.1210/endo-68-2-281 ↗
73. An analysis of the corrosion process of the Nova-T IUD10.1007/BF01984126 ↗