Effective easing of the side effects of copper intrauterine devices using ultra-fine-grained Cu-0.4Mg alloy
Source abstract
Abstract
Copper intrauterine device is one of the most adopted contraceptive methods with high effectiveness (over 99 %), low cost, spontaneous reversibility and long-lasting usage. However, the side effects induced from the initial burst release of copper ions (Cu2+) hinder the continuation of the Cu-IUD made of Coarse-Grained Copper (CG Cu). We proposed to tailor the bio-corrosion behaviors of better control of Cu2+ release via the addition of bioactive Mg into the Ultra-Fine Grained (UFG) Bulk Cu. Thus, UFG bulk Cu with 0.4 wt.% Mg was produced via equal-channel angular pressing. The microstructures of the UFG Cu-0.4Mg was observed using electron backscatter diffraction and transmission electron microscopy techniques. The in vitro long-term corrosion behaviors in simulated uterine fluid, cytotoxicity to four cell lines, in vivo biocompatibility and contraceptive efficacy were all studied on CG Cu, UFG Cu and UFG Cu-0.4Mg materials. The results demonstrate that both the ultrafine grains and the addition of bioactive Mg into Cu contribute to the suppression of the burst release of Cu2+ in the initial stage and the maintenance of high level Cu2+ in long-term release. Moreover, the UFG Cu-0.4Mg also exhibited much improved cell and tissue biocompatibility from both the in vitro and in vivo evaluations. Therefore, the contraceptive efficacy of UFG Cu-0.4Mg is still maintained as high as the CG Cu and UFG Cu while the side effects are significantly eased, suggesting the high potential of the UFG Cu-0.4Mg alloy as a new upgrading or alternative material for Cu-IUD. STATEMENT OF SIGNIFICANCE: The side effects from burst release of Cu2+ at the initial implantation stage of Cu-containing intrauterine devices (Cu-IUD) is one of the main drawbacks of these devices. In this work, an ultra-fine-grained Cu (UFG Cu) alloyed with a low amount of bioactive Mg was used for a Cu-IUD. The UFG Cu-0.4Mg alloy exhibited suppressed burst release of Cu2+ at initial implantation, while active Cu2+ release for long-term usage was maintained, comparable to coarse-grained pure Cu. Furthermore, the UFG Cu-0.4Mg alloy displayed significantly improved biocompatibility with human uterus cells and a much decreased inflammatory response within the uterus. Therefore, the side effects from Cu-IUD were eased, while high antifertility efficacy of the UFG Cu-0.4Mg alloy was maintained. The UFG Cu-0.4Mg alloy is promising for Cu-IUD.
Source: europepmc · Quality: candidate unverified · Source record ↗
Research context
OpenAlex topics: Magnesium Alloys: Properties and Applications · Orthopaedic implants and arthroplasty
SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.
References (73)
Show source-provided references
1. Corrosion of copper intrauterine devices: review and recent developments10.1515/corrrev-2019-0012 ↗
2. Long-acting reversible contraception10.1056/NEJMcp1608736 ↗
3. Intrauterine devices and contraceptive implants: overview of options and updates on method use10.1007/s13669-017-0200-8 ↗
4. Hormonal and intrauterine methods for contraception for women aged 25 years and younger
5. Copper-T intrauterine device and levonorgestrel intrauterine system: biological bases of their mechanism of action10.1016/j.contraception.2007.01.020 ↗
6. Release behavior of cupric ions for TCu380A and TCu220C IUDs10.1088/1748-6041/3/4/044114 ↗
7. Copper containing, framed intra-uterine devices for contraception
8. Relationship between copper IUD complications and ultrasonographic findings10.1007/s00404-018-4711-y ↗
9. Analysis of the reason of abnormal uterine bleeding induced by copper corrosion of IUD Cu10.12891/ceog3204.2016 ↗
10. Temporal trends of copper-bearing intrauterine device discontinuation: a population-based birth-cohort study of contraceptive use among rural married women in China10.1177/1010539513517259 ↗
11. Effects of copper and zinc on rat uterine muscle contraction and rabbit blastocyst fluid accumulation10.1095/biolreprod25.3.502 ↗
12. Discontinuation rates and acceptability during 1 year of using the intrauterine ball (the SCu380A)10.1016/j.contraception.2015.12.002 ↗
13. Reduction of the "burst release" of copper ions from copper-based intrauterine devices by organic inhibitors10.1016/j.contraception.2011.05.011 ↗
14. Decrease in cytotoxicity of copper-based intrauterine devices (IUD) pretreated with 6-mercaptopurine and pterin as biocompatible corrosion inhibitors10.1021/am3025307 ↗
15. Corrosion behavior of Cu and the Cu-Zn-Al shape memory alloy in simulated uterine fluid10.1016/j.contraception.2005.04.006 ↗
16. A porous Cu/LDPE composite for copper-containing intrauterine contraceptive devices10.1016/j.actbio.2011.09.024 ↗
17. Corrosion behavior of copper/LDPE nanocomposites in simulated uterine solution10.1016/j.biomaterials.2004.08.003 ↗
18. Biological evaluation of a novel copper-containing composite for contraception10.1016/j.fertnstert.2010.04.041 ↗
19. Zn(2+) release behavior and surface characteristics of Zn/LDPE nanocomposites and ZnO/LDPE nanocomposites in simulated uterine solution10.1007/s10856-008-3467-5 ↗
20. Zn2+ release from zinc and zinc oxide particles in simulated uterine solution10.1016/j.colsurfb.2005.12.007 ↗
21. Effective inhibition of the early copper ion burst release with ultra-fine grained copper and single crystal copper for intrauterine device application10.1016/j.actbio.2011.10.018 ↗
22. Corrosion and ion release behavior of ultra-fine grained bulk pure copper fabricated by ECAP in Hanks solution as potential biomaterial for contraception10.1016/j.matlet.2009.11.065 ↗
23. Biological response of chemically treated surface of the ultrafine-grained Ti-6Al-7Nb alloy for biomedical applications10.2147/IJN.S197099 ↗
24. Ultrafine grained titanium for biomedical applications: an overview of performance10.1016/j.jmrt.2013.07.003 ↗
25. Cellular response of preosteoblasts to nanograined/ultrafine-grained structures10.1016/j.actbio.2008.12.017 ↗
26. In vitro biocompatibility of an ultrafine grained zirconium10.1016/j.biomaterials.2007.06.015 ↗
27. Ultra-fine grained degradable magnesium for biomedical applications10.1016/S1875-5372(15)60001-7 ↗
28. Review of magnesium-based biomaterials and their applications10.1016/j.jma.2018.02.003 ↗
29. Role of cellular magnesium in health and human disease10.2741/1223 ↗
30. Magnesium and inflammation: advances and perspectives
31. Intravenous magnesium sulfate in the management of severe pre-eclampsia: a randomized study of 12-hour versus 24-hour maintenance dose10.1002/ijgo.13082 ↗
32. Risk factors for uterine atony/postpartum hemorrhage requiring treatment after vaginal delivery
33. Assessment of magnesium-based biomaterials: from bench to clinic10.1039/C9BM00289H ↗
34. Magnesium and its alloys as orthopedic biomaterials: a review10.1016/j.biomaterials.2005.10.003 ↗
35. Copper corrosion-simulated uterine solutions10.1016/S0010-7824(00)00124-4 ↗
36. 2004
37. In vitro and in vivo studies on magnesium alloys to evaluate the feasibility of their use in obstetrics and gynecology10.1016/j.actbio.2019.08.001 ↗
38. Magnesium-based sacrificial anode cathodic protection coatings (Mg-rich primers) for aluminum alloys10.3390/met2030353 ↗
39. Electrochemical stability of Cu–10Al–10Zn, Cu–10Al–10Ni, and Cu–10Ni–10Zn ternary alloys in simulated physiological solutions
40. Chronic systemic toxicity study of copper intrauterine devices in female Wistar rats10.12659/MSM.902137 ↗
41. Gold nanoshell nanomicelles for potential magnetic resonance imaging, light-triggered drug release, and photothermal therapy10.1002/adfm.201201663 ↗
42. Electrochemical behavior of mechanically alloyed hard Cu-Al alloys in marine environment10.1016/j.corsci.2019.03.043 ↗
43. Corrosion behavior of copper alloys in chloride media10.1016/j.matdes.2008.10.015 ↗
44. Effect of Ti content on corrosion behavior of Cu-Ti alloys in 3.5 % NaCl solution10.1016/S1003-6326(18)64699-0 ↗
45. The Cu-Mg (copper-magnesium) system10.1007/BF02868722 ↗
46. The development of binary Mg–Ca alloys for use as biodegradable materials within bone10.1016/j.biomaterials.2007.12.021 ↗
47. In vitro corrosion and biocompatibility of binary magnesium alloys10.1016/j.biomaterials.2008.10.021 ↗
48. Assessment of copper corrosion from frameless copper IUDs after long-term in utero residence10.1016/j.contraception.2014.05.009 ↗
49. Mechanisms of action of intrauterine devices: update and estimation of postfertilization effects10.1067/mob.2002.128091 ↗
50. Intrauterine devices: effective contraception with noncontraceptive benefits for adolescents10.1016/j.jpag.2019.07.001 ↗
51. Heavy metals and human spermatozoa. III. The toxicity of copper ions for spermatozoa10.1016/0010-7824(88)90050-9 ↗
52. Chemical reactions of the copper intrauterine device**supported by the ford foundation, grant 690010610.1016/S0015-0282(16)38703-9 ↗
53. Intrauterine devices: mechanisms of action, safety, and efficacy10.1016/S0010-7824(98)00082-1 ↗
54. Long-term safety, efficacy, and patient acceptability of the intrauterine copper T-380A contraceptive device10.2147/IJWH.S6914 ↗
55. Could the defects in the endometrial extracellular matrix during the implantation be a cause for impaired fertility?10.1111/j.1600-0897.2006.00443.x ↗
56. Alterations in the endometrium of rats, rabbits, and Macaca mulatta that received an implantation of copper/low-density polyethylene nanocomposite10.2147/IJN.S56756 ↗
57. The effect of copper on endometrial receptivity and induction of apoptosis on decidualized human endometrial stromal cells10.1177/1933719117732165 ↗
58. Effects of excess copper ions on decidualization of human endometrial stromal cells10.1007/s12011-016-0840-y ↗
59. Does over-exposure to copper ions released from metallic copper induce cytotoxic and genotoxic effects on mammalian cells?10.1016/j.contraception.2009.12.003 ↗
60. Bleeding, cramping, and satisfaction among new copper IUD users: a prospective study10.1371/journal.pone.0199724 ↗
61. In vitro cytotoxicity of Cu(2)(+), Zn(2)(+), Ag(+) and their mixtures on primary human endometrial epithelial cells10.1016/j.contraception.2011.09.016 ↗
62. Inflammatory cytokine profile of cocultivated primary cells from the endometrium of women with and without endometriosis
63. Correlative investigation of copper/low-density polyethylene nanocomposite on the endometrial angiogenesis in rats10.1007/s11684-007-0078-3 ↗
64. Changes in copper and zinc serum levels in women wearing a copper TCu-380A intrauterine device10.3109/13625187.2013.856404 ↗
65. Copper metallothioneins10.1002/iub.1618 ↗
66. Influence of magnesium substitution on a collagen–apatite biomaterial on the production of a calcifying matrix by human osteoblasts10.1002/(SICI)1097-4636(19981215)42:4<626::AID-JBM20>3.0.CO;2-S ↗
67. Novel magnesium alloys developed for biomedical application: a review10.1016/j.jmst.2013.02.005 ↗
68. Biodegradable Mg-Cu alloy implants with antibacterial activity for the treatment of osteomyelitis: in vitro and in vivo evaluations10.1016/j.biomaterials.2016.08.031 ↗
69. Magnesium sulfate infusion for acute asthma in the emergency department10.1016/j.jped.2017.06.002 ↗
70. Comparison of surface morphology and composition of intrauterine devices in relation to patient complaints10.1016/j.contraception.2004.03.006 ↗
71. Antifertility effectiveness of a novel copper-containing intrauterine device material and its influence on the endometrial environment in rats10.1016/j.msec.2018.04.025 ↗
72. The composition of rat uterine luminal fluid10.1210/endo-68-2-281 ↗
73. An analysis of the corrosion process of the Nova-T IUD10.1007/BF01984126 ↗