Enhanced bone formation in locally-optimised, low-stiffness additive manufactured titanium implants: An in silico and in vivo tibial advancement study
Source abstract
Abstract
A tibial tuberosity advancement (TTA), used to treat lameness in the canine stifle, provides a framework to investigate implant performance within an uneven loading environment due to the dominating patellar tendon. The purpose of this study was to reassess how we design orthopaedic implants in a load-bearing model to investigate potential for improved osseointegration capacity of fully-scaffolded mechanically-matched additive manufactured (AM) implants. While the mechanobiological nature of bone is well known, we have identified a lower limit in the literature where investigation into exceedingly soft scaffolds relative to trabecular bone ceases due to the trade-off in mechanical strength. We developed a finite element model of the sheep stifle to assess the stresses and strains of homogeneous and locally-optimised TTA implant designs. Using additive manufacturing, we printed three different low-stiffness Ti-6Al-4 V TTA implants: 0.8 GPa (Ti1), 0.6 GPa (Ti2) and an optimised design with a 0.3 GPa cortex and 0.1 GPa centre (Ti3), for implantation in a 12-week in vivo ovine pilot study. Static histomorphometry demonstrated uniform bone ingrowth in optimised low-modulus Ti3 samples compared to homogeneous designs (Ti1 and Ti2), and greater bone-implant contact. Mineralising surfaces were apparent in all implants, though mineral apposition rate was only consistent throughout Ti3. The greatest bone formation scores were seen in Ti3, followed by Ti2 and Ti1. Results from our study suggest lower stiffnesses and higher strain ranges improve early bone formation, and that by accounting for loading environments through rational design, implants can be optimised to improve uniform osseointegration. STATEMENT OF SIGNIFICANCE: The effect of different strain ranges on bone healing has been traditionally investigated and characterised through computational models, with much of the literature suggesting higher strain ranges being favourable. However, little has been done to incorporate strain-optimisation into porous orthopaedic implants due to the trade-off in mechanical strength required to induce these microenvironments. In this study, we used finite element analysis to optimise the design of additive manufactured (AM) titanium orthopaedic implants for different strain ranges, using a clinically-relevant surgical model. Our research suggests that there is potential for locally-optimised AM scaffolds in the use of orthopaedic devices to induce higher strains, which in turn encourages de novo bone formation and uniform osseointegration.
Source: europepmc · Quality: candidate unverified · Source record ↗
Research context
OpenAlex topics: Knee injuries and reconstruction techniques · Orthopedic Surgery and Rehabilitation · Bone fractures and treatments
SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.
References (76)
Show source-provided references
1. A survey of finite element analysis in orthopedic biomechanics: the first decade10.1016/0021-9290(83)90072-6 ↗
2. The micromechanical role of the annulus fibrosus components under physiological loading of the lumbar spine10.1115/1.4001032 ↗
3. A finite element model for predicting the biomechanical behaviour of the human lumbar spine10.1016/S0967-0661(01)00129-0 ↗
4. Finite element analysis in spine research10.1243/09544110260216568 ↗
5. Finite element analysis of moment-rotation relationships for human cervical spine10.1016/j.jbiomech.2004.10.029 ↗
6. Finite element analysis of human knee joint in varus-valgus10.1016/S0268-0033(97)00072-7 ↗
7. Finite element analysis of the effect of meniscal tears and meniscectomies on human knee biomechanics10.1016/j.clinbiomech.2005.01.009 ↗
8. Establishment and simulation of 3D geometric models of mini-pig and sheep knee joints using finite element analysis10.12659/MSM.921540 ↗
9. A review of computational models of bone fracture healing10.1007/s11517-017-1701-3 ↗
10. A mechano-regulation model for tissue differentiation during fracture healing: analysis of gap size and loading10.1016/S0021-9290(02)00086-6 ↗
11. Trabecular bone fracture healing simulation with finite element analysis and fuzzy logic10.1016/j.jbiomech.2004.10.019 ↗
12. Finite element analysis on the biomechanical stability of open porous titanium scaffolds for large segmental bone defects under physiological load conditions10.1016/j.medengphy.2012.06.006 ↗
13. Finite element analysis of porous commercially pure titanium for biomedical implant application10.1016/j.msea.2018.04.009 ↗
14. Effect of porous orthopaedic implant material and structure on load sharing with simulated bone ingrowth: a finite element analysis comparing titanium and PEEK10.1016/j.jmbbm.2018.01.017 ↗
15. Influence of the overall stiffness of a load-bearing porous titanium implant on bone ingrowth in critical-size mandibular bone defects in sheep10.1016/j.jmbbm.2016.02.036 ↗
16. Novel adaptive finite element algorithms to predict bone ingrowth in additive manufactured porous implants10.1016/j.jmbbm.2018.07.019 ↗
17. Titanium alloys in total joint replacement-a materials science perspective10.1016/S0142-9612(97)00146-4 ↗
18. Production of highly porous titanium (Ti) scaffolds by vacuum-assisted foaming of titanium hydride (TiH2) suspension10.1016/j.matlet.2014.01.065 ↗
19. Anisotropic porous titanium with superior mechanical compatibility in the range of physiological strain rate for trabecular bone implant applications10.1016/j.matlet.2014.09.047 ↗
20. Fabrication methods of porous metals for use in orthopaedic applications10.1016/j.biomaterials.2005.12.002 ↗
21. Development of new metallic alloys for biomedical applications10.1016/j.actbio.2012.06.037 ↗
22. Mechanobiologically optimized 3D titanium-mesh scaffolds enhance bone regeneration in critical segmental defects in sheep10.1126/scitranslmed.aam8828 ↗
23. Biomechanical stability of novel mechanically adapted open-porous titanium scaffolds in metatarsal bone defects of sheep10.1016/j.biomaterials.2014.12.010 ↗
24. Bone “mass” and the “mechanostat”: a proposal10.1002/ar.1092190104 ↗
25. Effects of mechanical factors on the fracture healing process10.1097/00003086-199810001-00015 ↗
26. Magnitudes of local stress and strain along bony surfaces predict the course and type of fracture healing10.1016/S0021-9290(98)00153-5 ↗
27. Biophysical stimuli on cells during tissue differentiation at implant interfaces10.1016/S0021-9290(96)00140-6 ↗
28. A unified theory of bone healing and nonunion10.1302/0301-620X.98B7.36061 ↗
29. Physical and biological aspects of fracture healing with special reference to internal fixation
30. Evolution of the internal fixation of long bone fractures. The scientific basis of biological internal fixation: choosing a new balance between stability and biology10.1302/0301-620X.84B8.0841093 ↗
31. A Mechanobiology-based Algorithm to Optimize the Microstructure Geometry of Bone Tissue Scaffolds10.7150/ijbs.13158 ↗
32. Dynamic cell stretching increases human osteoblast proliferation and CICP synthesis but decreases osteocalcin synthesis and alkaline phosphatase activity10.1016/S0021-9290(99)00171-2 ↗
33. Osteoregulatory nature of mechanical stimuli: function as a determinant for adaptive remodeling in bone10.1002/jor.1100050217 ↗
34. In vivo tracking of segmental bone defect healing reveals that callus patterning is related to early mechanical stimuli10.22203/eCM.v024a26 ↗
35. The design and in vivo testing of a locally stiffness-matched porous scaffold10.1016/j.apmt.2019.02.017 ↗
36. Trabecular-like Ti-6Al-4V scaffolds for orthopedic: fabrication by selective laser melting and in vitro biocompatibility10.1016/j.jmst.2019.01.012 ↗
37. Individual response variations in scaffold-guided bone regeneration are determined by independent strain- and injury-induced mechanisms10.1016/j.biomaterials.2018.11.026 ↗
38. Application of a 3D printed customized implant for canine cruciate ligament treatment by tibial tuberosity advancement10.1088/1758-5082/6/2/025005 ↗
39. Additively manufactured porous metallic biomaterials10.1039/C9TB00420C ↗
40. Mechanics of additively manufactured biomaterials10.1016/j.jmbbm.2017.03.018 ↗
41. Applications of Metal Additive Manufacturing in Veterinary Orthopedic Surgery10.1007/s11837-015-1295-x ↗
42. A Review of the Pathogenesis of Canine Cranial Cruciate Ligament Disease as a Basis for Future Preventive Strategies10.1111/j.1532-950X.2010.00654.x ↗
43. Prevalence of and risk factors for hip dysplasia and cranial cruciate ligament deficiency in dogs10.2460/javma.232.12.1818 ↗
44. Estimate of the annual economic impact of treatment of cranial cruciate ligament injury in dogs in the United States10.2460/javma.2005.227.1604 ↗
45. Tibial tuberosity advancement: what have we learned so far?10.12968/coan.2015.20.2.92 ↗
46. Advancement of the tibial tuberosity10.1097/00003086-197603000-00039 ↗
47. Computational design and fabrication of a novel bioresorbable cage for tibial tuberosity advancement application10.1016/j.jmbbm.2016.08.036 ↗
48. Canine cruciate ligament ruptures: implications for financial costs and human health10.1002/ar.24460 ↗
49. Animal models for implant biomaterial research in bone: a review10.22203/eCM.v013a01 ↗
50. Sheep Model in Orthopedic Research: a Literature Review
51. Fok · 2020
52. G. Treece, A. Gee, R. Prager, Stradwin, (2014). http://mi.eng.cam.ac.uk/∼rwp/stradwin.
53. Stress and strain distribution in the intact canine femur: finite element analysis10.1016/S1350-4533(03)00002-X ↗
54. Anatomical evaluation and stress distribution of intact canine femur10.1002/rcs.1457 ↗
55. Tibio-femoral joint contact forces in sheep10.1016/j.jbiomech.2005.02.006 ↗
56. Loads on Muscles, Tendons and Bones in the Hind Extremities of Sheep - A Theoretical study10.1111/j.1439-0264.1993.tb00343.x ↗
57. Analysis of inter-fragmentary movement as a function of musculoskeletal loading conditions in sheep10.1016/S0021-9290(97)00127-9 ↗
58. Getty · 1975
59. A modified Maquet-tibial tuberosity advancement technique for treatment of canine cranial cruciate ligament disease: short term outcome and complications10.1111/vsu.12733 ↗
60. The MAP Client: user-Friendly Musculoskeletal Modelling Workflows10.1007/978-3-319-12057-7_21 ↗
61. An octahedral shear strain-based measure of SNR for 3D MR elastography10.1088/0031-9155/56/13/N02 ↗
62. Elastic moduli, yield stress, and ultimate stress of cancellous bone in the canine proximal femur10.1016/0021-9290(87)90264-8 ↗
63. Distribution of Young's Modulus in the Cancellous of the Proximal Canine Tibia10.1016/0021-9290(94)90226-7 ↗
64. Interrelationship of trabecular mechanical and microstructural properties in sheep trabecular bone10.1016/j.jbiomech.2004.06.007 ↗
65. The use of an Ossis custom 3D-printed tri-flanged acetabular implant for major bone loss: minimum 2-year follow-up10.1177/1120700018760817 ↗
66. International Organization for Standardization, Mechanical testing of metals – Ductility testing – Compression test for porous and cellular metals (ISO Standard No. 13314:2011(E)), Geneva, Switzerland, 2011. www.iso.org.
67. Additively manufactured porous tantalum implants10.1016/j.actbio.2014.12.003 ↗
68. NIH Image to ImageJ: 25 years of image analysis10.1038/nmeth.2089 ↗
69. Fiji: an open-source platform for biological-image analysis10.1038/nmeth.2019 ↗
70. Trainable Weka Segmentation: a machine learning tool for microscopy pixel classification10.1093/bioinformatics/btx180 ↗
71. Bone histomorphometry: standardization of nomenclature, symbols, and units: report of the asbmr histomorphometry nomenclature committee10.1002/jbmr.5650020617 ↗
72. An in vivo ovine model of bone tissue alterations in simulated microgravity conditions
73. Bone regeneration during distraction osteogenesis: mechano-regulation by shear strain and fluid velocity10.1016/j.jbiomech.2006.09.028 ↗
74. Rationally designed functionally graded porous Ti6Al4V scaffolds with high strength and toughness built via selective laser melting for load-bearing orthopedic applications10.1016/j.jmbbm.2020.103673 ↗
75. Verification, validation and sensitivity studies in computational biomechanics10.1080/10255840601160484 ↗
76. Considerations for reporting finite element analysis studies in biomechanics10.1016/j.jbiomech.2011.11.038 ↗