Fracture of porcine aorta—Part 1: symconCT fracture testing and DIC
Source abstract
Abstract
Tissue failure and damage are inherent parts of vascular diseases and tightly linked to clinical events. Additionally, experimental set-ups designed to study classical engineering materials are suboptimal in the exploration of vessel wall fracture properties. The classical Compact Tension (CT) test was augmented to enable stable fracture propagation, resulting in the symmetry-constraint Compact Tension (symconCT) test, a suitable set-up for fracture testing of vascular tissue. The test was combined with Digital Image Correlation (DIC) to study tissue fracture in 45 porcine aorta specimens. Test specimens were loaded in axial and circumferential directions in a physiological solution at 37 °C. Loading the aortic vessel wall in the axial direction resulted in mode I tissue failure and a fracture path aligned with the circumferential vessel direction. Circumferential loading resulted in mode I-dominated failure with multiple deflections of the fracture path. The aorta ruptured at a principal Green-Lagrange strain of approximately 0.7, and strain rate peaks that develop ahead of the crack tip reached nearly 400 times the strain rate on average over the test specimen. It required approximately 70% more external work to fracture the aorta by circumferential than axial load; normalised with the fracture surface, similar energy levels are, however, observed. The symconCT test resulted in a stable fracture propagation, which, combined with DIC, provided a set-up for the in-depth analysis of vascular tissue failure. The high strain rates ahead of the crack tip indicate the significance of rate effects in the constitutive description of vascular tissue fracture. STATEMENT OF SIGNIFICANCE: This paper represents a significant step forward in understanding the fracture properties of porcine aorta. Inspired by the Compact Tension test, we developed an ad hoc experimental protocol to investigate stable crack propagation in soft materials, providing new insights into the mechanical processes that lead to the rupture of vascular tissue. The set-up enables the assessment of strains and strain rates ahead of the crack tip, and our findings could improve the clinical risk assessment of vascular pathologies as well as optimise medical device design.
Source: openalex_inverted_index · Quality: baseline
Research context
OpenAlex topics: Aortic aneurysm repair treatments · Aortic Disease and Treatment Approaches · Elasticity and Material Modeling
SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.
References (42)
Show source-provided references
1. Atherosclerosis10.1038/s41572-019-0106-z ↗
2. Global and regional prevalence, burden, and risk factors for carotid atherosclerosis: a systematic review, meta-analysis, and modelling study10.1016/S2214-109X(20)30117-0 ↗
3. Abdominal aortic aneurysm: update on pathogenesis and medical treatments10.1038/s41569-018-0114-9 ↗
4. Biomechanics of vascular mechanosensation and remodeling10.1091/mbc.E14-11-1522 ↗
5. Prediction of progression of coronary artery disease and clinical outcomes using vascular profiling of endothelial shear stress and arterial plaque characteristics: the PREDICTION study10.1161/CIRCULATIONAHA.112.096438 ↗
6. Molecular mechanisms of the vascular responses to hemodynamic forces
7. Review. biomechanical factors in the biology of aortic wall and aortic valve diseases10.1093/cvr/cvt040 ↗
8. A hypothesis for vulnerable plaque rupture due to stress-induced debonding around cellular microcalcifications in thin fibrous caps
9. Angiotensin II infusion into ApoE-/- mice: a model for aortic dissection rather than abdominal aortic aneurysm?10.1093/cvr/cvx128 ↗
10. Early morphofunctional changes in AngII-infused mice contribute to regional onset of aortic aneurysm and dissection10.1159/000509545 ↗
11. Cardiovascular Soft Tissue Mechanics
12. Biaxial rupture properties of ascending thoracic aortic aneurysms10.1016/j.actbio.2016.06.028 ↗
13. Tear propagation in isolated, pressurized porcine thoracic aortas
14. Development of a test method to investigate mode II fracture and dissection of arteries10.1016/j.actbio.2020.11.023 ↗
15. Dissection of the human aortic media: an experimental study10.1115/1.2898733 ↗
16. Failure mechanisms of ventricular tissue due to deep penetration10.1016/j.jbiomech.2008.12.016 ↗
17. Numerical simulation of the failure of ventricular tissue due to deep penetration: the impact of constitutive properties10.1016/j.jbiomech.2010.08.022 ↗
18. Characterization of fracture toughness exhaustion in pig aorta10.1016/j.jmbbm.2012.08.007 ↗
19. Characterization of fracture behavior of human atherosclerotic fibrous caps using a miniature single edge notched tensile test10.1016/j.actbio.2016.07.027 ↗
20. Experimental validation of a microcracking-based toughening mechanism for cortical bone10.1016/S0021-9290(02)00319-6 ↗
21. Re-evaluating the toughness of human cortical bone10.1016/j.bone.2005.10.014 ↗
22. Analysis of fracture processes in cortical bone tissue10.1016/j.engfracmech.2012.11.020 ↗
23. Microscopic assessment of bone toughness using scratch tests10.1016/j.bonr.2016.12.001 ↗
24. On the tear resistance of skin10.1038/ncomms7649 ↗
25. The toughness of porcine skin: quantitative measurements and microstructural characterization10.1016/j.jmbbm.2020.103848 ↗
26. Critical pressure of intramural delamination in aortic dissection10.1007/s10439-022-02906-3 ↗
27. Gasser · 2021
28. Collagen - Structure and Mechanics
29. Altered collagen fiber kinematics define the onset of localized ligament damage during loading10.1152/japplphysiol.90792.2008 ↗
30. Co-localization of microstructural damage and excessive mechanical strain at aortic branches in angiotensin-II-infused mice10.1007/s10237-019-01197-3 ↗
31. Alloisio · 2023
32. Cohesive zone modeling of mode I tearing in thin soft materials10.1016/j.jmbbm.2013.07.015 ↗
33. In vitro measurement of strain localization preceding dissection of the aortic wall subjected to radial tension10.1007/s11340-020-00641-1 ↗
34. Effect of layer heterogeneity on the biomechanical properties of ascending thoracic aortic aneurysms10.1007/s11517-012-0949-x ↗
35. Finite element formulation for a digital image correlation method
36. DIC challenge: developing images and guidelines for evaluating accuracy and resolution of 2d analyses10.1007/s11340-017-0349-0 ↗
37. Nonlinear viscoelastic, thermodynamically consistent, models for biological soft tissue10.1016/j.actbio.2017.12.027 ↗
38. Doroghazi · 1983
39. Dissecting aneurysm of the aorta: a review of 505 cases
40. Acute limited intimal tears of the thoracic aorta10.1016/j.jacc.2018.03.531 ↗
41. Positional variations in fracture toughness, stiffness and strength of descending thoracic pig aorta10.1016/0021-9290(83)90058-1 ↗
42. A path independent integral and the approximate analysis of strain concentration by notches and cracks10.1115/1.3601206 ↗