Stimuli-responsive pressure–strain sensor-based conductive hydrogel for alleviated non-alcoholic fatty liver disease by scavenging reactive oxygen species in adipose tissue
Source abstract
Abstract
A visible light- and reactive oxygen species (ROS)-responsive pressure/strain sensor based on carbon dot (CD)-loaded conductive hydrogel was developed for detecting high-fat diet (HFD) and preventing the risk of non-alcoholic fatty liver disease. The designed nanoparticle consisted of a diselenide polymer dot (dsPD) loaded with a visible light-responsive CD to form dsPD@CD (DSCD). The influence of visible light irradiation and ROS on DSCD facilitated the electron transport, enhancing the conductivity of DSCD-embedded hydrogel (DSCD hydrogel) from 1.3 to 35.9 mS/m. Alternatively, the tensile modulus of the DSCD hydrogel enhanced to 223 % after light-induced ROS treatment, which simultaneously impacted the capacitive response (120 %). The hydrogel implantation into inguinal white adipose tissue of HFD mice showed 82 % higher conductivity and 83 % enhanced pressure sensing response to HFD-generated high ROS levels compared with the normal diet-fed mice. Additionally, the ROS scavenging activity of DSCD hydrogel was confirmed by the downregulation of ROS-responsive genes, such as Sod2, Nrf2, and catalase (Cat) in murine primary hepatocytes isolated from fatty liver-induced mice. In addition, in vivo animal studies also confirmed the suppression of hepatic lipogenesis, as shown by decreased Pparγ and Fasn expression and hypertrophy of adipocytes in HFD mice. The distinguishable real-time wireless resistance response observed with pressure sensing indicates the potential application of the device for monitoring the risk of non-alcoholic fatty liver disease. STATEMENT OF SIGNIFICANCE: A visible-light-induced ROS-responsive carbon dot-loaded conductive hydrogel was developed for the detection of HFD-induced alterations in ROS levels by evaluating the conductivity and electrochemical responses with applied pressure/strain. The implanted hydrogel facilitates the recovery of the inflated adipocytes induced by NAFLD, which reduces fat accumulation in the liver, preventing the risk of NAFLD. Real-time detection based on the resistance response during local compression of the hydrogel is possibly performed utilizing a wireless sensing device, demonstrating the ease of NAFLD monitoring.
Source: europepmc · Quality: candidate unverified · Source record ↗
Research context
OpenAlex topics: Electrochemical sensors and biosensors · Adipose Tissue and Metabolism · Pancreatic function and diabetes
SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.
References (40)
Show source-provided references
1. Diabetes, hypertension, and cardiovascular disease: clinical insights and vascular mechanisms
2. Atherogenic dyslipidemia associated with metabolic syndrome and insulin resistance10.1016/S1098-3597(06)80005-0 ↗
3. Effect of a high fat, high sucrose diet on the promotion of non-alcoholic fatty liver disease in male rats: the ameliorative role of three natural compounds10.1186/s12944-015-0087-1 ↗
4. Macronutrients and the adipose-liver axis in obesity and fatty liver10.1016/j.jcmgh.2019.02.001 ↗
5. Adipose tissue as a buffer for daily lipid flux10.1007/s00125-002-0873-y ↗
6. Role of oxidative stress in the pathogenesis of nonalcoholic fatty liver disease10.1016/j.freeradbiomed.2020.02.025 ↗
7. Role of oxidative stress in pathophysiology of nonalcoholic fatty liver disease10.1155/2018/9547613 ↗
8. Role of oxidative stress in the pathogenesis of non-alcoholic fatty liver disease: implications for prevention and therapy10.3390/antiox10020174 ↗
9. Diet induces hepatocyte protection in fatty liver disease via modulation of PTEN signaling
10. Antioxidant dietary approach in treatment of fatty liver: new insights and updates10.3748/wjg.v23.i23.4146 ↗
11. Beyond the scavenging of reactive oxygen species (ROS): direct effect of cerium oxide nanoparticles in reducing fatty acids content in an in vitro model of hepatocellular steatosis10.3390/biom9090425 ↗
12. Epigallocatechin-3-gallate alleviates high-fat diet-induced nonalcoholic fatty liver disease via inhibition of apoptosis and promotion of autophagy through the ROS/MAPK signaling pathway
13. Tuning conductivity and roughness of diselenide polymer dot-coated surface for ROS-mediated selective real-time wireless detection of cancer cells10.1016/j.cej.2021.130880 ↗
14. GSH-responsive self-healable conductive hydrogel of highly sensitive strain-pressure sensor for cancer cell detection10.1016/j.nantod.2021.101178 ↗
15. Multifunctional injectable hydrogel for in vivo diagnostic and therapeutic applications10.1021/acsnano.1c07649 ↗
16. An injectable and conductive TEMPOL/polypyrrole integrated peptide co-assembly hydrogel promotes functional maturation of cardiomyocytes for myocardial infarction repair10.1016/j.compositesb.2022.109794 ↗
17. Pro-healing zwitterionic skin sensor enables multi-indicator distinction and continuous real-time monitoring10.1002/adfm.202106406 ↗
18. Reactive oxygen species-responsive and Raman-traceable hydrogel combining photodynamic and immune therapy for postsurgical cancer treatment10.1038/s41467-022-32160-z ↗
19. Stimuli-responsive electrodes detect oxidative stress and liver injury10.1002/adma.201404562 ↗
20. Double – network hydrogel based on exopolysaccharides as a biomimetic extracellular matrix to augment articular cartilage regeneration10.1016/j.actbio.2022.08.062 ↗
21. Light-induced swelling-responsive conductive, adhesive, and stretchable wireless film hydrogel as electronic artificial skin10.1002/adfm.201903209 ↗
22. Diselenide-bridged carbon-dot-mediated self-healing, conductive, and adhesive wireless hydrogel sensors for label-free breast cancer detection10.1021/acsnano.0c02517 ↗
23. Facile preparation of carbon quantum dots/TiO2 composites at room temperature with improved visible-light photocatalytic activity10.1016/j.jallcom.2021.159389 ↗
24. Diet-sensitive sources of reactive oxygen species in liver mitochondria: role of very long chain acyl-CoA dehydrogenases10.1371/journal.pone.0077088 ↗
25. ROS-responsive drug delivery systems for biomedical applications
26. A wear-resistant TiO2 nanoceramic coating on titanium implants for visible-light photocatalytic removal of organic residues10.1016/j.actbio.2019.08.009 ↗
27. Aggregatable thiol-functionalized carbon dots-based fluorescence strategy for highly sensitive detection of glucose based on target-initiated catalytic oxidation10.1016/j.snb.2020.129325 ↗
28. Recent advances in crystalline carbon dots for superior application potential10.1039/D0MA00108B ↗
29. Novel hybrid nanocomposite based on Poly(vinyl alcohol)/carbon quantum dots/fullerene (PVA/CQDs/C60) for thermoelectric power applications
30. Nitrogen-doped carbon dots/TiO2 nanoparticle composites for photoelectrochemical water oxidation10.1021/acsanm.9b02412 ↗
31. Dynamic monitoring and regulation of pentachlorophenol photodegradation process by chemiluminescence and TiO2/PDA10.1016/j.jhazmat.2020.123073 ↗
32. Super-strong and tough poly(vinyl alcohol)/poly(acrylic acid) hydrogels reinforced by hydrogen bonding10.1039/C8TB02556H ↗
33. Polydiacetylene hydrogel self-healing capacitive strain sensor10.1039/D0TC00576B ↗
34. Electrical stimulation for therapeutic approach10.1002/INMD.20230003 ↗
35. A highly stable and durable capacitive strain sensor based on dynamically super-tough hydro/organo-gels10.1002/adfm.202010830 ↗
36. A stretchable capacitive strain sensor having adjustable elastic modulus capability for wide-range force detection10.1002/adem.202070011 ↗
37. Graphdiyne-based flexible respiration sensors for monitoring human health10.1016/j.nantod.2021.101214 ↗
38. Chitosan derived nitrogen-doped carbon dots suppress osteoclastic osteolysis via downregulating ROS10.1039/D0NR02848G ↗
39. Carbon dots derived from folic acid attenuates osteoarthritis by protecting chondrocytes through NF-κB/MAPK pathway and reprogramming macrophages10.1186/s12951-022-01681-6 ↗
40. Targeting endogenous hydrogen peroxide at bone defects promotes bone repair