journal article·2025-05

A partially degradable composite consisting of Ti-Zr-Cu-Pd-Sn metallic glass and Fe-Mg alloy for orthopedic applications

Peng Du, Kun Zuo, Rongqiang Yan, Kun Li, Shilu Chen, Bo Yuan, Liang Zhang, Guoqiang Xie

Acta Biomaterialia· Volume 198
Publisher page

Abstract

Partially-degradable biomaterials refers to smart implants where biodegradable metals can gradually be replaced by newly growing bone or living tissues, and leave behind a porous inert metal skeleton that stably binds with the new bone tissue. In this research, a partially degradable composite was designed by integrating Ti-Zr-Cu-Pd-Sn metallic glass (MG) with designed Fe-Mg alloy using spark plasma sintering (SPS). The mechanical alloying technique successfully enabled the fusion of immiscible Fe and Mg, addressing the issues of Fe's slow degradation and Mg's rapid breakdown, while also minimizing potential fractures in the metal framework due to hydrogen gas evolution. The controlled degradation of Mg(Fe) promotes the formation of Ca-P compounds, enhancing the bioactivity of the Fe-Mg composite. This design endows the composite with plastic and ductile deformation under compression, providing a viable solution to the brittle fracture behaviour commonly associated with conventional bulk metallic glasses (BMGs). This advancement holds promise for aligning with the natural growth rate of human bone, further augmenting the bioactive properties and practical applications of the MG/Fe-Mg composite material. STATEMENT OF SIGNIFICANCE: In this research, a partially degradable composite was designed by integrating Ti-Zr-Cu-Pd-Sn metallic glass (MG) with designed Fe-Mg alloy using SPS. The Fe-Mg alloy act as temporary space holders can gradually being replaced by newly formed bone, thus establishing a dynamic equilibrium between the biodegradation of the bio-metals and the inward growth of new bone. The degradation of Mg(Fe) promotes the formation of Ca-P compounds, enhancing the bioactivity of the composite. This design endows the composite with plastic deformation under compression, providing a viable solution to the brittle fracture behavior of conventional MGs. This advancement holds promise for aligning with the natural growth rate of human bone, further augmenting the practical applications of the MG/Fe-Mg composite.
Source: europepmc · Quality: candidate unverified · Source record ↗

Research context

OpenAlex topics: Material Properties and Applications · Metallic Glasses and Amorphous Alloys · Polymer Science and Applications

SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.

References (49)

Show source-provided references
1. Recent advances in bulk metallic glasses for biomedical applications10.1016/j.actbio.2016.03.047 ↗
2. A review of the development of titanium-based and magnesium-based metallic glasses in the field of
3. Additive manufacturing of bulk metallic glasses: fundamental principle, current/future developments and applications10.1016/j.jmst.2021.09.068 ↗
4. Optimization of bioactivity and antibacterial properties of porous Ti-based bulk metallic glass through chemical treatment10.1016/j.ceramint.2022.12.278 ↗
5. Ti-based bulk metallic glass implantable biomaterial with adjustable porosity produced by a novel pressure regulation method in spark plasma sintering
6. Porous Ti-based bulk metallic glass orthopedic biomaterial with high strength and low Young's modulus produced by one step SPS10.1016/j.jmrt.2021.04.084 ↗
7. Enhanced mechanical and antibacterial properties of Cu-bearing Ti-based bulk metallic glass by controlling porous structure10.1016/j.jallcom.2022.164005 ↗
8. Corrosion behaviours of Ti6Al4V-Mg/Mg-alloy composites10.1016/j.corsci.2020.108470 ↗
9. Porous titanium with entangled structure filled with biodegradable magnesium for potential biomedical applications10.1016/j.msec.2014.11.014 ↗
10. Fundamental theory of biodegradable metals-definition, criteria, and design10.1002/adfm.201805402 ↗
11. Mechanical properties and corrosion resistance of powder metallurgical Mg-Zn-Ca/Fe bulk metal glass composites for biomedical application10.1016/j.jmst.2021.07.006 ↗
12. Fabrication of graded porous titanium-magnesium composite for load-bearing biomedical applications10.1016/j.matdes.2014.12.001 ↗
13. Powder metallurgical low-modulus Ti-Mg alloys for biomedical applications10.1016/j.msec.2015.06.010 ↗
14. A comparative study on biodegradation and mechanical properties of pressureless infiltrated Ti/Ti6Al4V-Mg composites10.1016/j.jmbbm.2016.06.026 ↗
15. Fabrication of graded porous titanium-magnesium composite for load-bearing biomedical applications10.1016/j.matdes.2014.12.001 ↗
16. Controlling the dissolution of iron through the development of nanostructured Fe-Mg for biomedical applications10.1016/j.actbio.2020.06.014 ↗
17. Solubility of iron in pure magnesium and cast structure of Mg-Fe alloy10.4028/www.scientific.net/MSF.419-422.697 ↗
18. Solid state synthesis of non-equilibrium phase in Mg-Co and Mg-Fe systems via bulk mechanical alloying10.2320/matertrans.44.601 ↗
19. Binary alloy phase diagrams
20. Mechanical alloying produces grain boundary segregation in Fe-Mg powders10.1016/j.scriptamat.2020.01.021 ↗
21. Ni-free Ti-based bulk metallic glass with potential for biomedical applications produced by spark plasma sintering10.1016/j.intermet.2012.05.006 ↗
22. Powder metallurgy process enables production of high-strength conductive Cu-based composites reinforced by Cu50Zr43Al7 metallic glass
23. Metallic glue for designing composite materials with tailorable properties10.1039/D1MH00521A ↗
24. PEEK versus metal cages in posterior lumbar interbody fusion: a clinical and radiological comparative study10.1007/s12306-018-0580-6 ↗
25. A randomized controlled trial comparing transforaminal lumbar interbody fusion and uninstrumented posterolateral fusion in the degenerative lumbar spine10.1055/s-0035-1549033 ↗
26. Trabecular metal spacers as standalone or with pedicle screw augmentation, in posterior lumbar interbody fusion: a prospective, randomized controlled trial10.1007/s00586-015-4229-y ↗
27. Posterior lumbar interbody fusion with stand-alone Trabecular metal cages for repeatedly recurrent lumbar disc herniation and back pain
28. Mechanical and structural investigation of porous bulk metallic glasses10.3390/met5020920 ↗
29. On the potential of bulk metallic glasses for dental implantology: case study on Ti40Zr10Cu36Pd1410.3390/ma11020249 ↗
30. Mechanical alloying of immiscible metallic systems: process, microstructure, and mechanism10.1002/adem.202001098 ↗
31. Mechanically driving supersaturated Fe-Mg solid solution for bone implant: preparation, solubility and degradation10.1016/j.compositesb.2020.108564 ↗
32. Core-shell Mg66Zn30Ca4 bulk metallic glasses composites reinforced by Fe with high strength and controllable degradation
33. Effect of powder size on strength and corrosion behavior of Mg66Zn30Ca4 bulk metallic glass10.1016/j.jallcom.2021.163219 ↗
34. Effect of composition on in vitro degradability of Ti–Mg metal-metal composites10.1016/j.msec.2019.110327 ↗
35. Microstructure, composition and hardness of laser-assisted hydroxyapatite and Ti-6Al-4V composite coatings10.1016/j.surfcoat.2013.06.006 ↗
36. Sol gel deposited hydroxyapatite-based coating technique on porous titanium niobium for biomedical applications: a mini review
37. Corrosion behaviour of porous Ni-free Ti-based bulk metallic glass produced by spark plasma sintering in Hanks' solution10.1016/j.intermet.2013.08.013 ↗
38. XPS study on the surface films of a newly designed Ni-free Ti-based bulk metallic glass10.1016/j.actamat.2006.10.054 ↗
39. The influence of porous structure on the corrosion behavior and biocompatibility of bulk Ti-based metallic glass10.1016/j.jallcom.2022.164326 ↗
40. Magnesium degradation under physiological conditions–Best practice
41. Magnesium research and applications: past, present and future10.1016/j.jma.2023.11.007 ↗
42. Novel bioactive materials developed by simulated body fluid evaluation: surface-modified Ti metal and its alloys10.1016/j.actbio.2016.08.013 ↗
43. Powder metallurgical low-modulus Ti-Mg alloys for biomedical applications10.1016/j.msec.2015.06.010 ↗
44. A review of techniques for the application of bioactive coatings on metal-based implants to achieve controlled release of active ingredients
45. A review of the physiological impact of rare earth elements and their uses in biomedical Mg alloys10.1016/j.actbio.2021.06.004 ↗
46. Magnesium alloys as extremely promising alternatives for temporary orthopedic implants-A review10.1016/j.jma.2023.08.002 ↗
47. Bone mechanics
48. Porous Ti-based bulk metallic glass with excellent mechanical properties and good biocompatibility10.1016/j.intermet.2018.12.002 ↗
49. Low Young's modulus Ti-based porous bulk glassy alloy without cytotoxic elements10.1016/j.actbio.2016.03.020 ↗