journal article·2011-10Open access

Bone bonding ability and handling properties of a titania–polymethylmethacrylate (PMMA) composite bioactive bone cement modified with a unique PMMA powder

C. Fukuda, K. Goto, M. Imamura, M. Neo, T. Nakamura

Acta Biomaterialia· Volume 7· Issue 10

Abstract

One of the challenges of using bioactive bone cements is adjusting their handling properties for clinical application. To resolve the poorer handling properties of bioactive bone cements we developed a novel bioactive bone cement containing a unique polymethylmethacrylate (PMMA) powder, termed SPD-PMMA (40 μm in diameter), composed of cohered minute particles of PMMA (0.5 μm). The present study aimed to examine the mechanical and handling properties and the in vivo bone bonding strength of this cement. The titania content of the cement varied from 10 to 30 wt.% (Ts10, Ts20, and Ts30). The mechanical and thermal properties of Ts10 and Ts20 exceeded those of commercially available PMMA cements (PMMAc). The setting properties of Ts20, including a shorter dough time and a working time that was comparable with that of PMMAc, were adequate for clinical application. Hardened cylindrical cement specimens were inserted into rabbit femurs and the interfacial shear strengths were measured by a push-out test at 6, 12, and 26 weeks after the operation. The interfacial shear strength values (in Newtons per square millimeter) of Ts10, Ts20, and Ts30 at 12 weeks and those of Ts20 and Ts30 at 26 weeks were significantly higher than that of PMMAc (P<0.05). These results show that a bioactive titania-PMMA composite bone cement modified by SPD-PMMA particles possesses adequate mechanical and handling properties, as well as osteoconductivity and in vivo bone bonding ability, and can be used for prosthesis fixation.
Source: europepmc · Quality: candidate unverified · Source record ↗

Research context

OpenAlex topics: Bone Tissue Engineering Materials · Orthopaedic implants and arthroplasty · Total Knee Arthroplasty Outcomes

SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.

References (20)

Show source-provided references
1. Anchorage of the femoral head prosthesis to the shaft of the femur10.1302/0301-620X.42B1.28 ↗
2. Observations upon the interface between bone and polymethylmethacrylate cement10.1302/0301-620X.64B4.7096429 ↗
3. Shear fatigue micromechanics of the cement–bone interface: an in vitro study using digital image correlation techniques10.1002/jor.20777 ↗
4. Fatigue creep damage at the cement–bone interface: an experimental and a micro-mechanical finite element study10.1016/j.jbiomech.2009.07.014 ↗
5. Hydroxyapatite impregnated bone cement: in vitro and in vivo studies
6. Effect of silane treatment and different resin compositions on biological properties of bioactive bone cement containing apatite–wollastonite glass ceramic powder10.1002/(SICI)1097-4636(19991205)47:3<336::AID-JBM7>3.0.CO;2-O ↗
7. Bioactive polymethyl methacrylate-based bone cement: comparison of glass beads, apatite- and wollastonite-containing glass–ceramic, and hydroxyapatite fillers on mechanical and biological properties10.1002/(SICI)1097-4636(200008)51:2<258::AID-JBM15>3.0.CO;2-S ↗
8. Evaluating chitosan/β-tricalcium phosphate/poly(methyl methacrylate) cement composites as bone-repairing materials10.1002/app.12590 ↗
9. Bioactive bone cements containing nano-sized titania particles for use as bone substitutes10.1016/j.biomaterials.2005.04.044 ↗
10. Mechanical, setting, and biological properties of bone cements containing micron-sized titania particles10.1007/s10856-007-3076-8 ↗
11. Bioactive bone cement with a low content of titania particles without postsilanization: effect of filler content on osteoconductivity, mechanical properties, and handling characteristics10.1002/jbm.b.31731 ↗
12. Bonelike hydroxyapatite induction by a gel-derived titania on a titanium substrate10.1111/j.1151-2916.1994.tb05407.x ↗
13. Bonding of chemically treated titanium implants to bone10.1002/(SICI)1097-4636(199711)37:2<267::AID-JBM17>3.0.CO;2-B ↗
14. Structural dependence of apatite formation on titania gels in a simulated body fluid10.1002/jbm.a.10414 ↗
15. A test for differences between treatment means when several dose levels are compared with a zero dose control10.2307/2528930 ↗
16. The comparison of several dose levels with a zero dose control10.2307/2556164 ↗
17. A study of the bioactive bone cement–bone interface: quantitative and histological evaluation10.1002/jab.770040104 ↗
18. A review of improvements in acrylic bone cements10.1177/088532829901400102 ↗
19. New aspects of the effect of size and size distribution on the setting parameters and mechanical properties of acrylic bone cements10.1016/0142-9612(96)82725-6 ↗
20. The initiation of failure in cemented femoral components of hip arthroplasties10.1302/0301-620X.73B4.2071634 ↗