journal article·2016-07

Fabrication and characteristics of dual functionalized vascular stent by spatio-temporal coating

Seong Min Kim, Kwang-Sook Park, Eugene Lih, Young Joon Hong, Jong Hee Kang, Ik Hwan Kim, Myung Ho Jeong, Yoon Ki Joung, Dong Keun Han

Acta Biomaterialia· Volume 38
Publisher page

Abstract

Unlabelled Stent implantation with balloon angioplasty is a widely used treatment for coronary artery diseases. Stents have been developed from bare metal stent (BMS) to advanced forms such as drug-eluting stent (DES). However, modern DES still causes thrombosis and/or in-stent restenosis as long-term outcomes. For effective prevention of these problems, we fabricated a dual functionalized stent using spatio-temporal coating, which has two different surfaces, as a novel type of DES. Hyaluronic acid conjugated with dopamine (HA-DA) was applied to a bare cobalt-chromium (CC) stent prior to abluminal coating of sirolimus (SRL)-in-polymer such as poly(d,l-lactide). The SRL-in-polymer (P+S) coated on the abluminal surface of the HA-DA modified stent showed highly stable coating layer and prevented the crack formation after ballooning. In the blood- and cyto-compatibility tests, HA-DA coating displayed suppressive effects on adhesion and activation of platelets and maintained the cell viability and proliferation of human coronary artery endothelial cells even under the existence of SRL. In in vivo study using porcine restenosis model, the neointimal area and inflammation score of the dual functionalized stent with HA-DA and P+S were significantly reduced than those of BMS. It is expected that this novel type of DES can be effectively applied to utilize diverse anti-proliferative drugs and bioactive polymers. Statement of significance Stents have been developed from bare metal stent to advanced forms such as drug-eluting stents (DESs). However, even DESs can still cause in-stent restenosis as long-term outcomes. This paper demonstrated a novel DES using spatio-temporal coating by dopamine-mediated hyaluronic acid coating (HA-DA) before asymmetric coating of sirolimus-in-poly(d,l-lactide) (P+S). It showed stable coating surface and prevented crack formation after ballooning. HA-DA coating also had an inhibitive effect on adhesion of platelets and maintained cell viability of endothelial cells even under the existence of sirolimus. Additionally, in vivo neointima area and inflammation score of HA-DA/P+S stent significantly decreased than those of BMS. We expected that this novel type of DES can be effectively applied to introduce diverse anti-proliferative drugs and bioactive molecules.
Source: europepmc · Quality: candidate unverified · Source record ↗

Research context

OpenAlex topics: Coronary Interventions and Diagnostics · Cerebrovascular and Carotid Artery Diseases · Polymer Surface Interaction Studies

SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.

References (48)

Show source-provided references
1. Emergent use of balloon-expandable coronary artery stenting for failed percutaneous transluminal coronary angioplasty10.1161/01.CIR.86.3.812 ↗
2. Intravascular stents to prevent occlusion and restenosis after transluminal angioplasty10.1056/NEJM198703193161201 ↗
3. Long-term clinical outcome after stent implantation in saphenous vein grafts10.1016/0735-1097(96)00104-0 ↗
4. Pathophysiology of restenosis: interaction of thrombosis, hyperplasia, and/or remodeling10.1016/S0002-9149(98)00191-X ↗
5. Restenosis after PCI. Part 1: pathophysiology and risk factors10.1038/nrcardio.2011.132 ↗
6. Randomized trial of three rapamycin-eluting stents with different coating strategies for the reduction of coronary restenosis10.1093/eurheartj/ehn253 ↗
7. Integrity of stent polymer layer after drug-eluting stent implantation: in vivo comparison of sirolimus-, paclitaxel-, zotarolimus- and everolimus-eluting stents10.1007/s12928-013-0191-y ↗
8. Polyurethane membrane with porous surface for controlled drug release in drug eluting stent10.1186/2055-7124-18-15 ↗
9. Stent thrombosis in randomized clinical trials of drug-eluting stents10.1056/NEJMoa067731 ↗
10. Coronary in-stent restenosis: current status and future strategies10.1016/S0735-1097(01)01742-9 ↗
11. Pathology of drug-eluting stents in humans: delayed healing and late thrombotic risk10.1016/j.jacc.2006.03.042 ↗
12. Localized hypersensitivity and late coronary thrombosis secondary to a sirolimus-eluting stent: should we be cautious?10.1161/01.CIR.0000116202.41966.D4 ↗
13. Enhanced dermal wound neovascularization by targeted delivery of endothelial progenitor cells using an RGD-g-PLLA scaffold10.1016/j.biomaterials.2009.03.053 ↗
14. Detailed analysis of polymer response to delivery balloon expansion of drug-eluting stents versus bare metal stents10.4244/EIJV9I3A62 ↗
15. Hyaluronan: from extracellular glue to pericellular cue10.1038/nrc1391 ↗
16. Biocompatibility and resorption pattern of newly developed hyaluronic acid hydrogel reinforced three-layer poly (lactide-co-glycolide) membrane: histologic observation in rabbit calvarial defect model10.1186/2055-7124-18-12 ↗
17. Hyaluronan and human endothelial cell behavior10.1080/03008200802148462 ↗
18. The role of hyaluronic acid in inflammation and wound healing
19. The role of hyaluronic acid in atherosclerosis and intimal hyperplasia10.1016/j.jss.2011.09.025 ↗
20. Prevention of postoperative pericardial adhesions with a hyaluronic acid coating solution. Experimental safety and efficacy studies10.1016/S0022-5223(12)70149-6 ↗
21. Reduced thrombus formation by hyaluronic acid coating of endovascular devices10.1161/01.ATV.20.4.1168 ↗
22. Hyaluronan – A functional and structural sweet spot in the tissue microenvironment10.3389/fimmu.2015.00231 ↗
23. Molecular basis of different outcomes for drug-eluting stents that release sirolimus or tacrolimus
24. Effects of interfacial layer wettability and thickness on the coating morphology and sirolimus release for drug-eluting stent10.1016/j.jcis.2015.08.051 ↗
25. Precise ultrasonic coating and controlled release of sirolimus with biodegradable polymers for drug-eluting stent
26. Effect of polymer-free TiO2 stent coated with abciximab or alpha lipoic acid in porcine coronary restenosis model10.1016/j.jjcc.2014.02.015 ↗
27. Controlled gene-eluting metal stent fabricated by bio-inspired surface modification with hyaluronic acid and deposition of DNA/PEI polyplexes10.1016/j.ijpharm.2009.09.042 ↗
28. Preparation of low-molecular-weight hyaluronic acid by ozone treatment10.1016/j.carbpol.2012.03.081 ↗
29. Deposition from dopamine solutions at Ge substrates: an in situ ATR-FTIR study10.1021/la202908b ↗
30. PH-induced metal-ligand cross-links inspired by mussel yield self-healing polymer networks with near-covalent elastic moduli10.1073/pnas.1015862108 ↗
31. Poly (D, L-lactic acid) homopolymers: Synthesis and characterization
32. Selective substitution of 31/42-OH in rapamycin guided by an in situ IR technique10.3390/molecules19067770 ↗
33. Development and physicochemical characterization of sirolimus solid dispersions prepared by solvent evaporation method
34. In vitro study of dual drug-eluting stents with locally focused sirolimus and atorvastatin release10.1007/s10856-013-5001-7 ↗
35. Improvement of interfacial adhesion of biodegradable polymers coated on metal surface by nanocoupling10.1021/la2030318 ↗
36. Crack prevention of biodegradable polymer coating on metal facilitated by a nano-coupled interlayer10.1177/0883911514547094 ↗
37. Nanocomposites of Poly(Lactic Acid) reinforced with cellulose nanofibrils10.15376/biores.5.3.1811-1823 ↗
38. Dual drug-eluting stents coated with multilayers of hydrophobic heparin and sirolimus10.1021/am403615q ↗
39. Fabrication of a novel polymer-free nanostructured drug-eluting coating for cardiovascular stents10.1021/am403365j ↗
40. Human fibrinogen specifically binds hyaluronic acid10.1016/S0021-9258(18)67129-7 ↗
41. Regulation of polyurethane hemocompatibility and endothelialization by tethered hyaluronic acid oligosaccharides10.1016/j.biomaterials.2009.06.029 ↗
42. In human endothelial cells rapamycin causes mTORC2 inhibition and impairs cell viability and function10.1093/cvr/cvn024 ↗
43. Rapamycin inhibits re-endothelialization after percutaneous coronary intervention by impeding the proliferation and migration of endothelial cells and inducing apoptosis of endothelial progenitor cells
44. Differential involvement of the hyaluronan (HA) receptors CD44 and receptor for HA-mediated motility in endothelial cell function and angiogenesis10.1074/jbc.M102273200 ↗
45. Oligosaccharides of hyaluronan induce angiogenesis through distinct CD44 and RHAMM-mediated signalling pathways involving Cdc2 and gamma-adducin
46. Reduced thrombus formation by hyaluronic acid coating of endovascular devices10.1161/01.ATV.20.4.1168 ↗
47. Long-term effects of polymer-based, slow-release, sirolimus-eluting stents in a porcine coronary model10.1016/j.cardiores.2004.04.029 ↗
48. Effect of a novel peptide, WKYMVm- and sirolimus-coated stent on re-endothelialization and anti-restenosis10.1007/s10856-015-5585-1 ↗