Thin films with chemically graded functionality based on fluorine polymers and stainless steel
Source abstract
Abstract
Thin films of stainless steel and poly(tetrafluoroethylene) were co-deposited, by radiofrequency magnetron sputtering, in an inert atmosphere in order to produce a functionally graded material as a coating on a traditional biomaterial, where non-ferromagnetic characteristics and improved wettability must be ensured. These thin films are intended to modify the surface of SS316L used in stents, where the bulk/thin film couple should be regarded as a single material. This requires excellent adhesion of the coating to the substrate. All coatings were deposited with an average thickness of 500 nm. The chemical and phase characterization of the surface revealed that, with the increase in F content, the thin film evolves from a ferritic phase (alpha) to an amorphous phase with dispersion of a new crystalline ceramic phase (FeF(2)). For intermediate F content values, an austenitic (111) phase (gamma) was present. Bearing in mind the envisaged application, the best results were attained for thin films with a fluorine content between 10 and 20 at.%.
Source: europepmc · Quality: candidate unverified · Source record ↗
Research context
OpenAlex topics: Metal and Thin Film Mechanics · Polymer Nanocomposite Synthesis and Irradiation · Tribology and Wear Analysis
SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.
References (35)
Show source-provided references
1. A clinical survey of vascular stents10.1080/136457002760273412 ↗
2. Thrombogenicity of various endovascular stent types: an in vitro evaluation10.1016/S1051-0443(07)61868-5 ↗
3. Endothelial cell migration onto metal stent surfaces under static and flow conditions
4. First in-human randomized comparison of an anodized niobium stent versus a standard stainless steel stent10.1007/s00392-006-0406-7 ↗
5. Evaluation of the Medtronic (driver) cobalt–chromium alloy coronary stent system10.1016/j.amjcard.2004.08.055 ↗
6. Clinical impact of stent construction and design in percutaneous coronary intervention10.1016/j.ahj.2003.12.007 ↗
7. Collapse pressures of biodegradable stents10.1016/S0142-9612(02)00640-3 ↗
8. Comparison of gold-coated NIR stents with uncoated NIR stents in patients with coronary artery disease10.1016/S0002-9149(02)02206-3 ↗
9. Increased risk of restenosis after placement of gold-coated stents: results of a randomized trial comparing gold-coated with uncoated steel stents in patients with coronary artery disease10.1161/01.CIR.101.21.2478 ↗
10. Randomised comparison of implantation of heparin-coated stents with balloon angioplasty in selected patients with coronary artery disease10.1016/S0140-6736(97)11128-X ↗
11. The SV stent study: a prospective, multicentre, angiographic evaluation of the BiodivYsio phosphorylcholine coated small vessel stent in small coronary vessels10.1016/j.ijcard.2004.04.001 ↗
12. Comparison of diamond-like carbon-coated stents versus uncoated stainless steel stents in coronary artery disease10.1016/j.amjcard.2003.10.048 ↗
13. Morrison · Diam Relat Mater · 2006 · 15 · 13810.1016/j.diamond.2005.08.031 ↗
14. Current drug-eluting stents in complex patients and lesions
15. Drug-eluting stents: role of stent design, delivery vehicle, and drug selection
16. Surface modification of metallic cardiovascular stents by strongly adhering aliphatic polyester coatings
17. Heparin incorporating liposomes as a delivery system of heparin from PET-covered metallic stents: effect on haemocompatibility10.1016/j.biomaterials.2005.11.017 ↗
18. Corrosion protection and repassivation after deformation of magnesium alloys coated with a protective magnesium fluoride layer
19. EN 1071-3:2005. Advanced technical ceramics – methods of test for ceramic coatings. Part B: Determination of adhesion and other mechanical failure modes by a scratch test; 2005.
20. EN ISO 14577-4:2007. Metallic materials – instrumented indentation test for hardness and materials parameters. Part 4: Test method for metallic and non-metallic coatings; 2007.
21. Ultra-microhardness testing procedure with Vickers indenter10.1016/S0257-8972(01)01413-X ↗
22. Piedade AP. Biomaterials and sputtering. PhD Thesis. Coimbra: University of Coimbra; 2000. p. 78.
23. Plasma treatments and plasma deposition of polymers for biomedical applications10.1016/S0257-8972(97)00285-5 ↗
24. Lide · 2004
25. Thermodynamic studies on chromium carbides by electromotive force (emf) method10.1016/S0925-8388(01)01012-X ↗
26. Pulsed laser deposited iron fluoride thin films for lithium–iron batteries10.1016/j.apsusc.2005.06.043 ↗
27. Influence of alloying elements on the corrosion performance of alloy 33 and alloy 24 in seawater10.1007/s11665-997-0076-2 ↗
28. Critical factors that determine face-centered cubic to body-centered cubic phase transformation in sputter-deposited austenitic stainless steel films10.1557/JMR.2004.0215 ↗
29. Sputtered stainless steel-carbon coatings as a substitute for hard electrolytic chromium for potential applications in mechanics10.1016/0921-5093(91)90517-Q ↗
30. Effect of fluorine implantation on the microstructure and microhardness of AISI440C stainless steel10.1016/S0168-583X(97)00227-9 ↗
31. Baker · 1992 · vol. 3
32. Goldschmidt · 1967
33. The crystal structures of stainless steel films sputter-deposited on austenitic stainless steel substrates10.1016/0956-716X(93)90454-Z ↗
34. Effects of ion flux on the properties of dc magnetron-sputtered stainless steel films10.1016/S0042-207X(02)00151-3 ↗
35. Structure and reactivity of water at biomaterial surfaces10.1016/S0001-8686(97)00040-7 ↗