journal article·2013-12

Characterization of polyethylene wear particle: The impact of methodology

Christian Schröder, Jörn Reinders, Carmen Zietz, Sandra Utzschneider, Rainer Bader, J. Philippe Kretzer

Acta Biomaterialia· Volume 9· Issue 12
Publisher page

Abstract

Due to the prevalence of problems caused by wear particles, the reduced durability of total joint replacements is well documented. The characterization of wear debris enables the size and morphology of these wear particles to be measured and provides an assessment of the biological response in vivo. However, the impact of different methodologies of particle analysis is not yet clear. Hence, the aim of this investigation was to analyze the influence of different particle characterization methods performed by three research centers within the scope of a "round robin test". To obtain knowledge about possible pitfalls, single steps of the particle characterization process (storage, pore size of the filter, coating durations by gold sputtering and scanning electron microscopy (SEM) magnification) were analyzed. The round robin test showed significant differences between the research groups, especially for the morphology of the particles. The SEM magnification was identified as having the greatest influence on the size and shape of the particles, followed by the storage conditions of the wear particle containing lubricant. Gold sputter coating and filter pore size also exhibit significant effects. However, even though they are statistically significant, it should be emphasized that the differences are small. In conclusion, particle characterization is a complex analytical method with a multiplicity of influencing factors. It becomes apparent that a comparison of wear particle results between different research groups is challenging.
Source: europepmc · Quality: candidate unverified · Source record ↗

Research context

OpenAlex topics: Orthopaedic implants and arthroplasty · Total Knee Arthroplasty Outcomes · Orthopedic Infections and Treatments

SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.

References (63)

Show source-provided references
1. The central role of wear debris in periprosthetic osteolysis10.1007/s11420-006-9003-6 ↗
2. Tissue reactions to plastic and metallic wear products of joint endoprostheses10.1097/00003086-199612000-00002 ↗
3. Polyethylene wear characteristics in vivo and in a knee stimulator10.1002/jbm.10139 ↗
4. Analysis of polyethylene particles produced in different wear conditions in vitro10.1097/00003086-200206000-00027 ↗
5. Wear analysis of unicondylar mobile bearing and fixed bearing knee systems: a knee simulator study10.1016/j.actbio.2010.09.031 ↗
6. Characterization of a highly cross-linked ultrahigh molecular-weight polyethylene in clinical use in total hip arthroplasty10.1016/j.arth.2007.06.006 ↗
7. Measures for reducing ultra-high-molecular-weight polyethylene wear in total knee replacement: a simulator study10.1515/BMT.2007.050 ↗
8. Particle analysis for the determination of UHMWPE wear10.1002/jbm.b.30213 ↗
9. Alteration of the amount and morphology of wear particles by the addition of loading profile transitions during artificial hip wear testing10.1243/09544119JEIM358 ↗
10. Influence of design and bearing material on polyethylene wear particle generation in total knee replacement10.1016/j.actbio.2009.03.016 ↗
11. Polyethylene wear debris produced in a knee simulator model: effect of crosslinking and counterface material10.1002/jbm.b.31491 ↗
12. Microwear phenomena of ultrahigh molecular weight polyethylene cups and debris morphology related to gamma radiation dose in simulator study10.1002/1097-4636(200107)56:1<65::AID-JBM1069>3.0.CO;2-Z ↗
13. Isolation of predominantly submicron-sized UHMWPE wear particles from periprosthetic tissues10.1002/jbm.820290118 ↗
14. Characterization of debris adjacent to failed knee implants of 3 different designs10.1097/00003086-199610000-00021 ↗
15. Particle size and morphology of UHMWPE wear debris in failed total knee arthroplasties–a comparison between mobile bearing and fixed bearing knees10.1016/S0736-0266(02)00015-3 ↗
16. In vivo comparison of wear particles between highly crosslinked polyethylene and conventional polyethylene in the same design of total knee arthroplasties10.1002/jbm.b.31458 ↗
17. The size and shape of particulate polyethylene wear debris in total joint replacements10.1243/0954411971534638 ↗
18. Number of polyethylene particles and osteolysis in total joint replacements. A quantitative study using a tissue-digestion method10.1302/0301-620X.79B5.7602 ↗
19. Analysis of polyethylene particles isolated from periprosthetic tissue of loosened hip arthroplasty and comparison with radiographic appearance10.1007/s00776-005-0896-6 ↗
20. Kossovsky NLKG, A.; Mellet, D. Size and mass quantification of sub-micron particulates in human synovial tissues recovered at revision. Proc of Ann Meet of Soc for Bionat 1991;242;5.
21. Comparison of UHMWPE particles in synovial fluid and tissues from failed THA10.1002/1097-4636(2001)58:2<196::AID-JBM1007>3.0.CO;2-R ↗
22. Isolation and characterization of wear particles generated in patients who have had failure of a hip arthroplasty without cement10.2106/00004623-199509000-00002 ↗
23. Isolation and characterization of debris in membranes around total joint prostheses10.2106/00004623-199411000-00010 ↗
24. In vivo analysis of polyethylene wear particles after total knee arthroplasty: the influence of improved materials and designs10.2106/JBJS.I.00447 ↗
25. Size and shape of biomaterial wear debris10.1016/0267-6605(94)90076-0 ↗
26. Shapes and dimensional characteristics of polyethylene wear particles generated in vivo by total knee replacements compared to total hip replacements10.1002/(SICI)1097-4636(199723)38:3<203::AID-JBM4>3.0.CO;2-T ↗
27. Quantitative analysis of ultrahigh molecular weight polyethylene (UHMWPE) wear debris associated with total knee replacements10.1002/(SICI)1097-4636(2000)53:1<100::AID-JBM14>3.0.CO;2-4 ↗
28. Composition and morphology of wear debris in failed uncemented total hip replacement10.1302/0301-620X.76B1.8300684 ↗
29. Isolation, characterization and quantification of polyethylene wear debris from periprosthetic tissues around total joint replacements10.1016/j.wear.2006.11.005 ↗
30. A new method for isolation of polyethylene wear debris from tissue and synovial fluid10.1016/j.biomaterials.2004.01.001 ↗
31. Polyethylene and metal wear particles: characteristics and biological effects10.1007/s00281-011-0242-3 ↗
32. International Standard ISO 17853:2011 Wear of implant materials – Polymer and metal wear partices – isolation and characterization. Geneva; 2011.
33. Biotribology of alternative bearing materials for unicompartmental knee arthroplasty10.1016/j.actbio.2010.04.003 ↗
34. Influence of resting periods on polyethylene wear in a knee simulator study
35. Effect of joint laxity on polyethylene wear in total knee replacement10.1016/j.jbiomech.2009.12.016 ↗
36. Evaluation of different methods to eliminate adherent endotoxin of polyethylene wear particles10.1016/j.wear.2012.07.018 ↗
37. Establishment of a novel in vitro test setup exposing adherent cells to wear particles made of polyethylene10.1016/j.polymertesting.2013.05.005 ↗
38. Comparison of three joint simulator wear debris isolation techniques: acid digestion, base digestion, and enzyme cleavage10.1002/1097-4636(200108)56:2<245::AID-JBM1091>3.0.CO;2-T ↗
39. American Society for Testing and Materials International Standard ASTM F1877-05 (2010) Standard Practice for Characterization of Particles. West Conshohocken: ASTM, 2010.
40. Induction of macrophage apoptosis by ceramic and polyethylene particles in vitro10.1016/S0142-9612(98)00214-2 ↗
41. The relationship of polyethylene wear to particle size, distribution, and number: A possible factor explaining the risk of osteolysis after hip arthroplasty10.1002/jbm.b.31638 ↗
42. Differential apoptotic response of J774 macrophages to alumina and ultra-high-molecular-weight polyethylene particles10.1016/S0736-0266(01)00077-8 ↗
43. Macrophage/particle interactions: effect of size, composition and surface area10.1002/jbm.820280111 ↗
44. Do current wear particle isolation procedures underestimate the number of particles generated by prosthetic bearing components?10.1016/S0043-1648(01)00762-1 ↗
45. Nanometer size wear debris denerated from crosslinked and non-crosslinked ultra high molecular weight polyethylene in artificial joints10.1016/j.wear.2005.02.035 ↗
46. Nanometer size wear debris generated from ultra high molecular weight polyethylene in vivo10.1016/j.wear.2008.06.005 ↗
47. Identification of nanometre-sized ultra-high molecular weight polyethylene wear particles in samples retrieved in vivo10.1302/0301-620X.90B8.20737 ↗
48. Isolation and characterization of UHMWPE wear particles down to ten nanometers in size from in vitro hip and knee joint simulators10.1002/jbm.a.30824 ↗
49. Particle release in metal-on-metal bearings. A risk analysis10.1007/s00132-008-1297-2 ↗
50. The John Charnley Award: an accurate and extremely sensitive method to separate, display, and characterize wear debris: part 2: metal and ceramic particles10.1007/s11999-011-2058-9 ↗
51. The John Charnley Award: an accurate and sensitive method to separate, display, and characterize wear debris: part 1: polyethylene particles10.1007/s11999-011-2057-x ↗
52. Biotribology of a new bearing material combination in a rotating hinge knee articulation10.1016/j.actbio.2013.02.030 ↗
53. Calf serum constituent fractions influence polyethylene wear and microbial growth in knee simulator testing10.1177/0954411912444248 ↗
54. Effects of digestion protocols on the isolation and characterization of metal–metal wear particles. I Analysis of particle size and shape10.1002/1097-4636(20010605)55:3<320::AID-JBM1020>3.0.CO;2-3 ↗
55. Effects of digestion protocols on the isolation and characterization of metal-metal wear particles. II Analysis of ion release and particle composition10.1002/1097-4636(20010605)55:3<330::AID-JBM1021>3.0.CO;2-Y ↗
56. Nano-osteoimmunology as an important consideration in the design of future implants10.1016/j.actbio.2011.04.011 ↗
57. Gladkisa LG, Li RW, Scarvell JM, Smith PN, Timmersa H. Exploration of the size, shape and abundance of UHMWPE wear particles using atomic force microscopy. Wear 2009;267:632–638.10.1016/j.wear.2008.11.024 ↗
58. Metal wear particle characterization from metal on metal total hip replacements: transmission electron microscopy study of periprosthetic tissues and isolated particles10.1002/(SICI)1097-4636(199810)42:1<103::AID-JBM13>3.0.CO;2-M ↗
59. Fixed and mobile bearing total knee arthroplasty-influence on wear generation, corresponding wear areas, knee kinematics and particle composition10.1016/j.clinbiomech.2008.11.006 ↗
60. Quantitative analysis of UHMWPE wear debris isolated from the periprosthetic femoral tissues from a series of Charnley total hip arthroplasties
61. Characterisation of wear debris from UHMWPE on zirconia ceramic, metal-on-metal and alumina ceramic-on-ceramic hip prostheses generated in a physiological anatomical hip joint simulator10.1016/S0043-1648(01)00653-6 ↗
62. Quantitative analysis of polyethylene wear debris, wear rate and head damage in retrieved Charnley hip prostheses10.1023/A:1008901302646 ↗
63. Highly crosslinked polyethylene in posterior-stabilized total knee arthroplasty: in vitro performance evaluation of wear, delamination, and tibial post durability10.1016/j.arth.2010.02.010 ↗