In situ cell culture monitoring on a Ti–6Al–4V surface by electrochemical techniques
Source abstract
Abstract
In this work, the in situ interaction between Ti-6Al-4V alloy and osteoblastic cells has been studied by electrochemical techniques as a function of time. The interaction has been monitored for cell adhesion and growth of human osteoblastic Saos-2 cells on Ti-6Al-4V samples. The study has been carried out by electrochemical techniques, e.g., studying the evolution of corrosion potential with exposure time and by electrochemical impedance spectroscopy. The impedance results have been analyzed by using different equivalent circuit models that simulate the interface state at each testing time. The adhesion of the osteoblastic cells on the Ti-6Al-4V alloy leads to surface areas with different cell coverage rates, thus showing the different responses in the impedance diagrams with time. The effect of the cells on the electrochemical response of Ti-6Al-4V alloy is clearly seen after 4 days of testing, in which two isolated and well-differentiated time constants are clearly observed. One of these is associated with the presence of the cells and the other with a passive film on the Ti-6Al-4V alloy. After 7 days of culture, the system is governed by a resistive component over a wide frequency range which is associated with an increase in the cell coverage rate on the surface due to the extracellular matrix.
Source: europepmc · Quality: candidate unverified · Source record ↗
Research context
OpenAlex topics: Titanium Alloys Microstructure and Properties · Bone Tissue Engineering Materials · Metal and Thin Film Mechanics
SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.
References (29)
Show source-provided references
1. Calcium phosphate naturally formed on titanium in electrolyte solution10.1016/0142-9612(91)90028-9 ↗
2. Characterization of surface film formed on titanium in electrolyte using XPS10.1016/0169-4332(92)90178-Z ↗
3. Mechanism of adsorption of human albumin to titanium in vitro10.1002/(SICI)1097-4636(19970905)36:3<387::AID-JBM13>3.0.CO;2-B ↗
4. Reactivity of titanium in physiological medium I. Electrochemical characterization of the metal/protein interface10.1149/1.2769819 ↗
5. Metal ion release from metal implants10.1016/j.msec.2004.08.018 ↗
6. Evaluation techniques of metallic biomaterials in vitro10.1016/S1468-6996(02)00028-1 ↗
7. Electrochemical properties of an interface between titanium and fibroblasts L92910.1016/S0013-4686(02)00684-9 ↗
8. Development of electrolytic cell with cell-culture for metallic biomaterials10.1016/S0010-938X(01)00110-X ↗
9. In situ surface electrochemical characterizations of Ti and Ti–6Al–4V alloy cultured with osteoblast-like cells10.1016/j.bbrc.2003.12.173 ↗
10. Cell-extracellular matrix interaction and physico-chemical characteristics of titanium surfaces depend on the roughness of the material10.1016/S1389-0344(02)00047-3 ↗
11. Surface electrochemical impedance in situ monitoring of cell-cultured titanium with a nano-network surface layer10.1016/j.scriptamat.2005.07.006 ↗
12. Electric cell-substrate impedance sensing (ECIS) as a non invasive means to monitor the kinetics of cell spreading to artificial surfaces10.1006/excr.2000.4919 ↗
13. Electrochemical impedance spectroscopy and X-ray photoelectron spectroscopy analysis of titanium surfaces cultured with osteoblast-like cells derived from human mandibular bone10.1002/jbm.1275 ↗
14. EIS characterization of a Ti-dental implant in artificial saliva media: dissolution process of the oxide barrier10.1016/j.jelechem.2004.01.011 ↗
15. Rosca JCM. EIS study of Ti and its alloys in biological media10.1016/S0022-0728(02)00814-8 ↗
16. Alonso C, García-Alonso MC, Escudero ML. Electrolytic cell used for electrochemical analysis of metallic implant and cell culture interface. ES Patent No. 200801041, 2008.
17. Correlation of morphology and barrier properties of thin microwave plasma polymer films on metal substrate10.1016/j.electacta.2003.12.030 ↗
18. EIS evaluation of attached and free polymer films10.1016/S0300-9440(99)00076-4 ↗
19. 3D, chemical and electrochemical characterization of blasted Ti–6Al–4V surfaces: its influence on the corrosion behaviour10.1016/j.electacta.2006.12.031 ↗
20. Passive film on orthopaedic Ti–Al–V alloy formed in physiological solution investigated by X-ray photoelectron spectroscopy10.1016/S0142-9612(00)00145-9 ↗
21. Thermal oxidation enhances early interactions between human osteoblasts and alumina blasted Ti–6Al–4V alloy10.1002/jbm.a.30994 ↗
22. Corrosion behavior of titanium in the presence of calcium phosphate and serum proteins10.1016/j.biomaterials.2005.05.047 ↗
23. Characterization of implant materials in fetal bovine serum and sodium sulfate by electrochemical impedance spectroscopy. I. Mechanically polished samples10.1002/jbm.10329 ↗
24. In vitro simulation of biocompatibility of Ti–Al–V10.1002/jbm.820220305 ↗
25. Metal ion release from titanium with active oxygen species generated by rat macrophages in vitro10.1002/(SICI)1097-4636(200002)49:2<238::AID-JBM12>3.0.CO;2-J ↗
26. Bovine serum albumin adsorption on titania surfaces and its relation to wettability aspects10.1002/(SICI)1097-4636(19990905)46:3<376::AID-JBM10>3.0.CO;2-T ↗
27. Proteoglycans at the bone-implant interface10.1177/10454411980090040401 ↗
28. Barranco V, Saldaña L, Escudero ML, García-Alonso MC. X-ray photoelectron spectroscopy analysis of Ti-6A1-4V surfaces cultured with osteoblastic cells. Rev. Metal Madrid, submitted for publication.
29. Characterization of three-dimensional tissue cultures using electrical impedance spectroscopy10.1016/S0006-3495(99)77416-3 ↗