journal article·2007-04

Monte Carlo simulations of stray neutron radiation exposures in proton therapy

Yuanshui Zheng, Wayne Newhauser, Jonas Fontenot, Nicholas Koch, Radhe Mohan

Journal of Nuclear Materials· Volume 361· Issue 2-3
Publisher page

Abstract

Abstract Proton radiotherapy patients receive unwanted stray neutron radiation generated in the treatment apparatus. The literature on this neutron radiation is sparse and disparate and pertains mainly to unique or antiquated systems. The present work reports on neutron dose equivalent per therapeutic absorbed dose (H/D) in a contemporary proton therapy system. We applied the Monte Carlo method to predict neutron exposure as a function of treatment field size and location in the treatment room. For a 250-MeV proton beam, H/D values at isocenter increased from 13 to 20 mSv Gy−1 as the collimating aperture was decreased from 18 × 18 to 0 × 0 cm2. H/D values generally decreased with distance from isocenter (20 mSv Gy−1 at isocenter versus 0.9 mSv Gy−1 at a distance of 150 cm). Neutron spectral fluence calculations revealed that >50% of the dose equivalent at all locations considered was from neutrons >10 MeV.
Source: openaire · Quality: candidate unverified · Source record ↗

Research context

OpenAlex topics: Radiation Therapy and Dosimetry · Radiation Detection and Scintillator Technologies · Advanced Radiotherapy Techniques

SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.

References (24)

Show source-provided references
1. Koehler · Nucl. Instrum. and Meth. · 1975 · 131 · 43710.1016/0029-554X(75)90430-9 ↗
2. Koehler · Med. Phys. · 1977 · 4 · 29710.1118/1.594317 ↗
3. B. Gottschalk, A.M. Koehler, J.M. Sisterson, M.S. Wagner, in: H. Blattmann (Ed.), Report 111, Proceedings of the Radiotherapy Workshop, held at the Paul Scherrer Institute, 29 February–1 March, 1991, P.S.I., Villigen, Switzerland, 1991, p. 50.
4. Sisterson · Nucl. Instrum. and Meth. B · 2005 · 241 · 71310.1016/j.nimb.2005.07.121 ↗
5. Binns · Radiat. Prot. Dosim. · 1997 · 70 · 44110.1093/oxfordjournals.rpd.a031993 ↗
6. Agosteo · Radiother. Oncol. · 1998 · 48 · 29310.1016/S0167-8140(98)00049-8 ↗
7. Yan · Nucl. Instrum. and Meth. A · 2002 · 476 · 42910.1016/S0168-9002(01)01483-8 ↗
8. Polf · Phys. Med. Biol. · 2005 · 50 · 385910.1088/0031-9155/50/16/014 ↗
9. Polf · Radiat. Prot. Dosim. · 2005 · 115 · 15410.1093/rpd/nci264 ↗
10. Fontenot · Radiat. Prot. Dosim. · 2005 · 116 · 21110.1093/rpd/nci229 ↗
11. Schneider · Int. J. Radiat. Oncol. Biol. Phys. · 2002 · 54 · 24410.1016/S0360-3016(01)02826-7 ↗
12. Roy · Radiat. Phys. Chem. · 2004 · 71 · 99710.1016/j.radphyschem.2004.05.025 ↗
13. Jiang · Phys. Med. Biol. · 2005 · 50 · 433710.1088/0031-9155/50/18/007 ↗
14. 2005
15. Hérault · Med. Phys. · 2005 · 32 · 91010.1118/1.1871392 ↗
16. Chadwick · Nucl. Sci. Eng. · 1999 · 131 · 29310.13182/NSE98-48 ↗
17. Bertini · Phys. Rev. · 1968 · 188 · 171110.1103/PhysRev.188.1711 ↗
18. Yariv · Phys. Rev. · 1979 · 20 · 2227
19. Y. Zheng, W.D. Newhauser, J.D. Fontenot, N.C. Koch, in: Proceedings of the American Nuclear Society 14th Biennial Topical Meeting of the Radiation Protection and Shielding Division, held 3–6 April 2006, American Nuclear Society, Carlsbad, NM, 2006, p. 256.
20. W. Newhauser, J. Fontenot, Y. Zheng, J. Polf, U. Titt, N. Koch, R. Mohan, Phys. Med. Biol., submitted for publication.
21. International Commission on Radiation Units and Measurements (ICRU), ICRU Report Number 60, ICRU, Bethesda, MD, 1998.
22. National Council on Radiation Protection and Measurements (NCRP), NCRP Report 38, NCRP, Bethesda, MD, 1971.
23. A. Koehler, W. Preston, unpublished manuscript, Cambridge, MA, Harvard Cyclotron Laboratory, 1967.
24. Jongen · Bull. Cancer/Radiother. · 1996 · 83 · 219s10.1016/0924-4212(96)84917-6 ↗