Analysis of neutron attenuation in boron-alloyed stainless steel with neutron radiography and JEN-3 gauge
Source abstract
Abstract
This paper concerns the neutron attenuation behavior of boron-alloyed stainless steels, and quantitative estimations of secondary effects on the neutron transmission measurements, such as beam hardening, background and micro-structure of neutron absorber causing a decrease in the total macroscopic cross-sections. Systematic thermal neutron transmission measurements of boron-alloyed steel plates have been performed at different neutron radiography facilities and at a portable gauge called JEN-3, which is a practical neutron transmission setup for industrial demands in non-destructive material inspection. In addition, MCNP (Monte Carlo Neutron Particle transport) simulations were performed for a better understanding of the experimental results, the secondary factors affecting the total macroscopic cross-sections, and the characteristics of the JEN-3 gauge. The detectable thickness limit for 1.88 wt% natural boron-alloyed steel plates was determined as 1–1.5 cm depending on the contributions of the secondary factors in each facility.
Source: openaire · Quality: candidate unverified · Source record ↗
Research context
OpenAlex topics: Nuclear Physics and Applications · Advanced X-ray and CT Imaging · Radiation Detection and Scintillator Technologies
SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.
References (13)
Show source-provided references
1. Neutron scattering lengths and cross-sections10.1080/10448639208218770 ↗
2. Domanus · 1992
3. Vilpponen · Scand. J. Metall. (Stockholm) · 1974 · 2 · 298
4. Böhler-Bleche GmbH, Sheet and Plate for Nuclear Engineering, Böhler NEUTRONIT Archives, AV4/0281/77 (1997), and BBG/T/Dr.K/August 2001. Available from:
5. J.F. Briesmeister, MCNPTM – A General Monte Carlo N-Particle Transport Code, vols. 1–4, Version 4b
6. C.J. Leliveld, A fast Monte Carlo simulator for scattering in X-ray computerized tomography, Thesis, Zurich, Switzerland, 1996
7. M. Bastürk, Material inspections with low energy neutrons and 3D image reconstruction, Thesis, TU-Vienna, Austria, 2003
8. IAEA Nuclear Data Service. Available from:
9. Zawisky · J. Appl. Radiat. Isotopes · 2004 · 61 · 51710.1016/j.apradiso.2004.03.077 ↗
10. S. Körner, Digital image processing in neutron radiography, Thesis, TU-Vienna, 2000
11. B. Schillinger, Neue Entwicklungen zur Radiographie und Tomographie mit thermischen Neutronen und zu deren routinemäßigem Einsatz, Dissertation TU Munich, Mensch & Buch Verlag, Berlin, 1999
12. Zawisky · J. Nucl. Mater. · 2004 · 327 · 18810.1016/j.jnucmat.2004.02.011 ↗
13. N. Kardjilov, Further developments and applications of radiography and tomography with thermal and cold neutrons, Thesis, TU-Munich, Germany 2003. Available from: