journal article·2007-06

High heat load properties of actively cooled tungsten/copper mock-ups by explosive joining

H. Li, J.L. Chen, J.G. Li, Z.X. Li

Publisher page

Abstract

Two actively cooled mock-ups with 2 mm thick tungsten armor joined to chromium copper alloy by explosive welding were developed, tested and analyzed in ASIPP of China. The heat load limit of the mock-up is 7 MW/m 2 , and delamination was observed along the W/Cu interface. The mock-ups can withstand the maximum heat flux of 6 MW/m 2 . SEM investigations showed that some cracks and failures appeared in filler materials and at copper/filler interface, but intactness was found at tungsten/filler interface. Numerical simulations indicated that if the distance decreases between the vertex of channel and the interface, the mock-up had the better structure reliability due to the reduction of temperature and stress. Under 4 MW/m 2 heat flux, the mock-up showed good heat transfer capabilities and high joint reliabilities. All these results demonstrate the explosive joining is also an alternative way to realize the W/Cu joint for the plasma facing components.
Source: openaire · Quality: candidate unverified · Source record ↗

Research context

OpenAlex topics: Electronic Packaging and Soldering Technologies · Metal and Thin Film Mechanics · Advanced Welding Techniques Analysis

SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.

References (9)

Show source-provided references
1. Cadden · J. Nucl. Mater. · 2000 · 283–287 · 125310.1016/S0022-3115(00)00178-1 ↗
2. Ch. Friedrich et al., The manufacturing of the ITER divertor small scale mock-up, Plansee Report, TZ 2076, 1996.
3. A. Makhankov, I. Mazul, V. Safronov, et al., in: Proceedings of the 20th Symposium on Fusion Technology, Marseille, September 1998, vol. 1, p. 267.
4. B.Riccardi, A.Pizzuto, A.Orsini, et al., in: Proceedings of the 20th Symposium On Fusion Technology, Marseille, France, September 1998, p. 223.
5. ITER Final Report on Task T432, Extended & fatigue testing of L-5 task components, TA No G 17 TT fr 40 FR, RF Home Team, July 2001.
6. Merola · J. Nucl. Mater. · 2002 · 307–311 · 152410.1016/S0022-3115(02)01070-X ↗
7. Giniatulin · Fusion Eng. Des. · 1998 · 39&40 · 38510.1016/S0920-3796(98)00217-8 ↗
8. Huseh · Composite: Part B · 2003 · 34 · 74710.1016/S1359-8368(03)00088-X ↗
9. Chapa · J. Nucl. Mater. · 2002 · 303 · 13110.1016/S0022-3115(02)00820-6 ↗