Applications of three-dimensional printers in prosthetic dentistry
Source abstract
Abstract
This narrative review aims to provide an overview of recent studies and case reports on three-dimensional (3D) printing, and to verify the applicability of 3D printers in the field of dental prostheses. This review was performed by conducting a search of PubMed. The clinical application of fabricating a prosthesis made with cobalt-chromium is considered possible depending on the material and hardware of the 3D printer. However, it is currently difficult to assess the clinical use of 3D-printed zirconia crowns. Further research is required, such as verification of materials used, margin morphology, and hardware. Clinically acceptable results have been reported for patterns using 3D printers. Interim restorations made using a 3D printer have been reported with good results that are considered clinically usable. Dentures made with 3D printers need further verification in terms of strength and deformation. Custom trays made with 3D printers are clinically useful, however, issues remain with design time and effort. Although several studies have reported the usefulness of 3D printers, further verification is required since 3D printers are still considered new technology.
Source: openalex_inverted_index · Quality: baseline
Research context
OpenAlex topics: Anatomy and Medical Technology · 3D Printing in Biomedical Research · Dental materials and restorations
SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.
Affiliations
Department of Prosthodontics and Oral Implantology, School of Dentistry, Iwate Medical University
Department of Dysphagia Rehabilitation, Nagasaki University Hospital
References (66)
Show source-provided references
1. 1. Berman B (2012) 3-D printing: The new industrial revolution. Business Horizons 55, 155-162.10.1016/j.bushor.2011.11.003 ↗
2. 2. Rekow D (1987) Computer-aided design and manufacturing in dentistry: a review of the state of the art. J Prosthet Dent 58, 512-516.10.1016/0022-3913(87)90285-X ↗
3. 3. Duret F, Blouin JL, Duret B (1988) CAD-CAM in dentistry. J Am Dent Assoc 117, 715-720.10.14219/jada.archive.1988.0096 ↗
4. 4. Leinfelder KF, Isenberg BP, Essig ME (1989) A new method for generating ceramic restorations: a CAD-CAM system. J Am Dent Assoc 118, 703-707.10.14219/jada.archive.1989.0156 ↗
5. 5. Mormann WH, Brandestini M, Lutz F, Barbakow F (1989) Chairside computer-aided direct ceramic inlays. Quintessence Int 20, 329-339.
6. 6. Rekow ED (1991) Dental CAD-CAM systems. What is the state of the art? J Am Dent Assoc 122, 42-48.10.14219/jada.archive.1991.0205 ↗
7. 7. Mormann W, Krejci I (1992) Computer-designed inlays after 5 years in situ: clinical performance and scanning electron microscopic evaluation. Quintessence Int 23, 109-115.
8. 8. van der Zel JM (1993) Ceramic-fused-to-metal restorations with a new CAD-CAM system. Quintessence Int 24, 769-778.
9. 9. Smith BG, Cardwell JE (1989) One visit ceramic restorations made at the chairside: the cerec machine. Restorative Dent 5, 60-65.
10. 10. Markowski A (1990) A CAD-CAM ceramic inlay technique. J Esthet Dent 2, 170-176.10.1111/j.1708-8240.1990.tb00640.x ↗
11. 11. Mormann WH, Brandestini M, Lutz F, Barbakow F, Gotsch T (1990) CAD-CAM ceramic inlays and onlays: a case report after 3 years in place. J Am Dent Assoc 120, 517-520.10.14219/jada.archive.1990.0086 ↗
12. 12. Mormann WH, Curilović Z (1991) CEREC(R) CAD-CAM ceramic restorations. A case report after 5 years in place. Acta Stomatol Croat 25, 3-10.
13. 13. Isenberg BP, Essig ME, Leinfelder KF (1992) Three-year clinical evaluation of CAD/CAM restorations. J Esthet Dent 4, 173-176.10.1111/j.1708-8240.1992.tb00690.x ↗
14. 14. Cohen A, Laviv A, Berman P, Nashef R, Abu-Tair J (2014) Mandibular reconstruction using stereolithographic 3-dimensional printing modeling technology. Oral Surg Oral Med Oral Pathol Oral Radiol Endod 108, 661-666.10.1016/j.tripleo.2009.05.023 ↗
15. 15. Palhazi P, Nemes B, Swennen G, Nagy K (2014) Three-dimensional simulation of the nasoalveolar cleft defect. Cleft Palate Craniofac J 51, 593-596.10.1597/13-041 ↗
16. 16. Cousley RR, Turner MJ (2014) Digital model planning and computerized fabrication of orthognathic surgery wafers. J Orthod 41, 38-45.10.1179/1465313313Y.0000000075 ↗
17. 17. Ayoub AF, Rehab M, O’Neil M, Khambay B, Ju X, Barbenel J et al. (2014) A novel approach for planning orthognathic surgery: The integration of dental casts into three-dimensional printed mandibular models. Int J Oral Maxillofac Surg 43, 454-459.10.1016/j.ijom.2013.08.016 ↗
18. 18. Schepers RH, Raghoebar GM, Vissink A, Lahoda LU, Van der Meer WJ, Roodenburg JL et al. (2013) Fully 3-dimensional digitally planned reconstruction of a mandible with a free vascularized fibula and immediate placement of an implant-supported prosthetic construction. Head Neck 35, E109-114.10.1002/hed.21922 ↗
19. 19. Flugge TV, Nelson K, Schmelzeisen R, Metzger MC (2013) Three-dimensional plotting and printing of an implant drilling guide: simplifying guided implant surgery. J Oral Maxillofac Surg 71, 1340-1346.10.1016/j.joms.2013.04.010 ↗
20. 20. Obregon F, Vaquette C, Ivanovski S, Hutmacher DW, Bertassoni LE (2015) Three-dimensional bioprinting for regenerative dentistry and craniofacial tissue engineering. J Dent Res 94, 143S-152S.10.1177/0022034515588885 ↗
21. 21. Athirasala A, Tahayeri A, Thrivikraman G, Franca CM, Monteiro N, Tran V et al. (2018) A dentin-derived hydrogel bioink for 3D bioprinting of cell laden scaffolds for regenerative dentistry. Biofabrication 10, 024101.10.1088/1758-5090/aa9b4e ↗
22. 22. Ma Y, Xie L, Yang B, Tian W (2019) Three-dimensional printing biotechnology for the regeneration of the tooth and tooth-supporting tissues. Biotechnol Bioeng 116, 452-468.10.1002/bit.26882 ↗
23. 23. Thattaruparambil Raveendran N, Vaquette C, Meinert C, Samuel Ipe D, Ivanovski S (2019) Optimization of 3D bioprinting of periodontal ligament cells. Dent Mater 35, 1683-1694.10.1016/j.dental.2019.08.114 ↗
24. 24. Inzana JA, Olvera D, Fuller SM, Kelly JP, Graeve OA, Schwarz EM et al. (2014) 3D printing of composite calcium phosphate and collagen scaffolds for bone regeneration. Biomaterials 35, 4026-4034.10.1016/j.biomaterials.2014.01.064 ↗
25. 25. Do AV, Khorsand B, Geary SM, Salem AK (2015) 3D printing of scaffolds for tissue regeneration applications. Adv Healthc Mater 4, 1742-1762.10.1002/adhm.201500168 ↗
26. 26. Wu Z, Su X, Xu Y, Kong B, Sun W, Mi S (2016) Bioprinting three-dimensional cell-laden tissue constructs with controllable degradation. Sci Rep 6, 24474.10.1038/srep24474 ↗
27. 27. Ozbolat IT, Hospodiuk M (2016) Current advances and future perspectives in extrusion-based bioprinting. Biomaterials 76, 321-343.10.1016/j.biomaterials.2015.10.076 ↗
28. 28. Trombetta R, Inzana JA, Schwarz EM, Kates SL, Awad HA (2017) 3D printing of calcium phosphate ceramics for bone tissue engineering and drug delivery. Ann Biomed Eng 45, 23-44.10.1007/s10439-016-1678-3 ↗
29. 29. Keul C, Stawarczyk B, Erdelt KJ, Beuer F, Edelhoff D, Guth JF (2014) Fit of 4-unit fdps made of zirconia and CoCr-alloy after chairside and labside digitalization--a laboratory study. Dent Mater 30, 400-407.10.1016/j.dental.2014.01.006 ↗
30. 30. An S, Kim S, Choi H, Lee JH, Moon HS (2014) Evaluating the marginal fit of zirconia copings with digital impressions with an intraoral digital scanner. J Prosthet Dent 112, 1171-1175.10.1016/j.prosdent.2013.12.024 ↗
31. 31. Bertolini Mde M, Kempen J, Lourenco EJ, Telles Dde M (2014) The use of CAD/CAM technology to fabricate a custom ceramic implant abutment: a clinical report. J Prosthet Dent 111, 362-366.10.1016/j.prosdent.2013.08.016 ↗
32. 32. Huttig F, Keitel JP, Prutscher A, Spintzyk S, Klink A (2017) Fixed dental prostheses and single-tooth crowns based on ceria-stabilized tetragonal zirconia/alumina nanocomposite frameworks: outcome after 2 years in a clinical trial. Int J Prosthodont 30, 461-464.10.11607/ijp.5116 ↗
33. 33. Cenci SN, Gontarsky IA, Moro MG, Pinheiro LOB, Buhrer Samra AP (2017) Anterosuperior rehabilitation with metal-free fixed prosthesis based on zirconia. Eur J Dent 11, 253-257.10.4103/ejd.ejd_57_17 ↗
34. 34. Naveau A, Rignon-Bret C, Wulfman C (2019) Zirconia abutments in the anterior region: a systematic review of mechanical and esthetic outcomes. J Prosthet Dent 121, 775-781.10.1016/j.prosdent.2018.08.005 ↗
35. 35. Jang Y, Sim JY, Park JK, Kim WC, Kim HY, Kim JH (2018) Evaluation of the marginal and internal fit of a single crown fabricated based on a three-dimensional printed model. J Adv Prosthodont 10, 367-373.10.4047/jap.2018.10.5.367 ↗
36. 36. Sim JY, Jang Y, Kim WC, Kim HY, Lee DH, Kim JH (2019) Comparing the accuracy (trueness and precision) of models of fixed dental prostheses fabricated by digital and conventional workflows. J Prosthodont Res 63, 25-30.10.1016/j.jpor.2018.02.002 ↗
37. 37. Choi JW, Ahn JJ, Son K, Huh JB (2019) Three-dimensional evaluation on accuracy of conventional and milled gypsum models and 3D printed photopolymer models. Materials (Basel) 12, 3499.10.3390/ma12213499 ↗
38. 38. Wang W, Yu H, Liu Y, Jiang X, Gao B (2019) Trueness analysis of zirconia crowns fabricated with 3-dimensional printing. J Prosthet Dent 121, 285-291.10.1016/j.prosdent.2018.04.012 ↗
39. 39. Li R, Wang Y, Hu M, Wang Y, Xv Y, Liu Y et al. (2019) Strength and adaptation of stereolithography-fabricated zirconia dental crowns: an in vitro study. Int J Prosthodont 32, 439-443.10.11607/ijp.6262 ↗
40. 40. Chang HS, Peng YT, Hung WL, Hsu ML (2019) Evaluation of marginal adaptation of Co-Cr-Mo metal crowns fabricated by traditional method and computer-aided technologies. J Dent Sci 14, 288-294.10.1016/j.jds.2018.11.006 ↗
41. 41. V Harish, Ali S. A. Mohamed, N Jagadesan, Ifthikar Mohamed, Senthil Siva, Basak Debasish et al. (2014) Evaluation of internal and marginal fit of two metal ceramic system - in vitro study. J Clin Diagn Res 8, ZC53- ZC56.
42. 42. Sundar MK, Chikmagalur SB, Pasha F (2014) Marginal fit and microleakage of cast and metal laser sintered copings--an in vitro study. J Prosthodont Res 58, 252-258.10.1016/j.jpor.2014.07.002 ↗
43. 43. Park JK, Lee WS, Kim HY, Kim WC, Kim JH (2015) Accuracy evaluation of metal copings fabricated by computer-aided milling and direct metal laser sintering systems. J Adv Prosthodont 7, 122-128.10.4047/jap.2015.7.2.122 ↗
44. 44. Huang Z, Zhang L, Zhu J, Zhao Y, Zhang X (2015) Clinical marginal and internal fit of crowns fabricated using different CAD/CAM technologies. J Prosthodont 24, 291-295.10.1111/jopr.12209 ↗
45. 45. Ates SM, Yesil Duymus Z (2016) Influence of tooth preparation design on fitting accuracy of CAD-CAM based restorations. J Esthet Restor Dent 28, 238-246.10.1111/jerd.12208 ↗
46. 46. Gunsoy S, Ulusoy M (2016) Evaluation of marginal/internal fit of chrome-cobalt crowns: direct laser metal sintering versus computer-aided design and computer-aided manufacturing. Niger J Clin Pract 19, 636-644.10.4103/1119-3077.188699 ↗
47. 47. Dahl BE, Ronold HJ, Dahl JE (2017) Internal fit of single crowns produced by CAD-CAM and lost-wax metal casting technique assessed by the triple-scan protocol. J Prosthet Dent 117, 400-404.10.1016/j.prosdent.2016.06.017 ↗
48. 48. Lovgren N, Roxner R, Klemendz S, Larsson C (2017) Effect of production method on surface roughness, marginal and internal fit, and retention of cobalt-chromium single crowns. J Prosthet Dent 118, 95-101.10.1016/j.prosdent.2016.09.025 ↗
49. 49. Kim KB, Kim WC, Kim HY, Kim JH (2013) An evaluation of marginal fit of three-unit fixed dental prostheses fabricated by direct metal laser sintering system. Dent Mater 29, e91-e96.10.1016/j.dental.2013.04.007 ↗
50. 50. Nesse H, Ulstein DM, Vaage MM, Oilo M (2015) Internal and marginal fit of cobalt-chromium fixed dental prostheses fabricated with 3 different techniques. J Prosthet Dent 114, 686-692.10.1016/j.prosdent.2015.05.007 ↗
51. 51. Revilla-Leon M, Olea-Vielba M, Esteso-Saiz A, Martinez-Klemm I, Ozcan M (2018) Marginal and internal gap of handmade, milled and 3D printed additive manufactured patterns for pressed lithium disilicate onlay restorations. Eur J Prosthodont Restor Dent 26, 31-38.
52. 52. Khaledi AA, Farzin M, Akhlaghian M, Pardis S, Mir N (2020) Evaluation of the marginal fit of metal copings fabricated by using 3 different CAD-CAM techniques: milling, stereolithography, and 3D wax printer. J Prosthet Dent 124, 81-86.10.1016/j.prosdent.2019.09.002 ↗
53. 53. Lee WS, Lee DH, Lee KB (2017) Evaluation of internal fit of interim crown fabricated with CAD/CAM milling and 3D printing system. J Adv Prosthodont 9, 265-270.10.4047/jap.2017.9.4.265 ↗
54. 54. Mai HN, Lee KB, Lee DH (2017) Fit of interim crowns fabricated using photopolymer-jetting 3D printing. J Prosthet Dent 118, 208-215.10.1016/j.prosdent.2016.10.030 ↗
55. 55. Alharbi N, Alharbi S, Cuijpers V, Osman RB, Wismeijer D (2018) Three-dimensional evaluation of marginal and internal fit of 3D-printed interim restorations fabricated on different finish line designs. J Prosthodont Res 62, 218-226.10.1016/j.jpor.2017.09.002 ↗
56. 56. Molinero-Mourelle P, Canals S, Gomez-Polo M, Sola-Ruiz MF, Del Rio Highsmith J, Vinuela AC (2018) Polylactic acid as a material for three-dimensional printing of provisional restorations. Int J Prosthodont 31, 349-350.10.11607/ijp.5709 ↗
57. 57. Tahayeri A, Morgan M, Fugolin AP, Bompolaki D, Athirasala A, Pfeifer CS et al. (2018) 3D printed versus conventionally cured provisional crown and bridge dental materials. Dent Mater 34, 192-200.10.1016/j.dental.2017.10.003 ↗
58. 58. Chaturvedi S, Alqahtani NM, Addas MK, Alfarsi MA (2020) Marginal and internal fit of provisional crowns fabricated using 3D printing technology. Technol Health Care 6, 635-642.10.3233/THC-191964 ↗
59. 59. Chen H, Li H, Zhao Y, Zhang X, Wang Y, Lyu P (2019) Adaptation of removable partial denture frameworks fabricated by selective laser melting. J Prosthet Dent 122, 316-324.10.1016/j.prosdent.2018.11.010 ↗
60. 60. Tasaka A, Shimizu T, Kato Y, Okano H, Ida Y, Higuchi S et al. (2020) Accuracy of removable partial denture framework fabricated by casting with a 3D printed pattern and selective laser sintering. J Prosthodont Res 64, 224-230.10.1016/j.jpor.2019.07.009 ↗
61. 61. Tasaka A, Matsunaga S, Odaka K, Ishizaki K, Ueda T, Abe S et al. (2019) Accuracy and retention of denture base fabricated by heat curing and additive manufacturing. J Prosthodont Res 63, 85-89.10.1016/j.jpor.2018.08.007 ↗
62. 62. Choi JJE, Uy CE, Plaksina P, Ramani RS, Ganjigatti R, Waddell JN (2020) Bond strength of denture teeth to heat-cured, CAD/CAM and 3D printed denture acrylics. J Prosthodont 29, 415-421.10.1111/jopr.13125 ↗
63. 63. Liu Y, Di P, Zhao Y, Hao Q, Tian J, Cui H (2019) Accuracy of multi-implant impressions using 3d-printing custom trays and splinting versus conventional techniques for complete arches. Int J Oral Maxillofac Implants 34, 1007-1014.10.11607/jomi.7049 ↗
64. 64. Deng K, Chen H, Li R, Li L, Wang Y, Zhou Y et al. (2019) Clinical evaluation of tissue stops on 3D-printed custom trays. Sci Rep 9, 1807.10.1038/s41598-018-37826-7 ↗
65. 65. Xu Y, Huettig F, Schille C, Schweizer E, Geis-Gerstorfer J, Spintzyk S (2020) Peel bond strength between 3D printing tray materials and elastomeric impression/adhesive systems: A laboratory study. Dent Mater 36, e241-e254.10.1016/j.dental.2020.04.015 ↗
66. 66. Sun Y, Chen H, Li H, Deng K, Zhao T, Wang Y et al. (2017) Clinical evaluation of final impressions from three-dimensional printed custom trays. Sci Rep 7, 14958.10.1038/s41598-017-14005-8 ↗