Comparative assessment of subjective image quality of cross-sectional cone-beam computed tomography scans
Source abstract
Abstract
Since the introduction of cone-beam computed tomography (CBCT), several novel systems with different technical specifications and settings have become commercially available. Therefore, it is essential to evaluate CBCT systems for differences in the subjective quality of images obtained for various dental procedures. We evaluated the subjective image quality of cross-sectional scans obtained from various CBCT systems. Images of three cadaver mandibles were obtained from four different CBCT units: 1) Veraviewepocs 3D 40 × 40 mm field of view (FOV) (voxel size: 0.125 × 0.125 × 0.125 mm), 2) Iluma, low-resolution (voxel size: 0.3 × 0.3 × 0.3 mm), 3) Kodak, 50 × 3.7 cm FOV (voxel size: 0.076 × 0.076 × 0.076 mm), and 4) Vatech 12 × 8.5cm FOV (voxel size: 0.160 × 0.160 × 0.160 mm). We assessed subjective image quality and the visibility of 10 specific features, namely, caries, amalgam restoration, final implant drill, root canal filling, metal crown, mandibular canal, mental foramen, tooth (periodontal ligament space and lamina dura), trabecular pattern, and soft tissue. Images were viewed and scored by five calibrated observers, and image quality was ranked from best to worst. The Veraviewepocs 3D had the highest quality images for most of the assessed features, whereas the Iluma low-resolution scans were rated as the lowest quality images.
Source: openalex_inverted_index · Quality: baseline
Research context
OpenAlex topics: Dental Radiography and Imaging · Advanced X-ray and CT Imaging · Dental Implant Techniques and Outcomes
SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.
References (23)
Show source-provided references
1. 1. Scarfe WC, Farman AG, Levin MD, Gane D (2010) Essentials of maxillofacial cone beam computed tomography. Alpha Omegan 103, 62-67.10.1016/j.aodf.2010.04.001 ↗
2. 10.1097/01.HP.0000326340.81581.1a10.1097/01.HP.0000326340.81581.1a ↗
3. 3. Kamburoglu K, Kolsuz E, Kurt H, Kiliç C, Özen T, Paksoy CS (2011) Accuracy of CBCT measurements of a human skull. J Digit Imaging 24, 787-793.10.1007/s10278-010-9339-9 ↗
4. 4. Kamburoglu K, Kurt H, Kolsuz E, Öztas B, Tatar I, Çelik HH (2011) Occlusal caries depth measurements obtained by five different imaging modalities. J Digit Imaging 24, 804-813.10.1007/s10278-010-9355-9 ↗
5. 5. Feldkamp LA, Davis LC, Kress JW (1984) Practical cone-beam algorithm. J Opt Soc Am 1, 612-619.10.1364/JOSAA.1.000612 ↗
6. 10.1016/j.ijom.2009.02.02810.1016/j.ijom.2009.02.028 ↗
7. 7. White SC, Pharoah MJ (2008) The evolution and application of dental maxillofacial imaging modalities. Dent Clin North Am 52, 689-705.10.1016/j.cden.2008.05.006 ↗
8. 8. Scarfe WC, Farman AG (2008) What is cone-beam CT and how does it work? Dent Clin North Am 52, 707-730.10.1016/j.cden.2008.05.005 ↗
9. 9. Scarfe WC, Farman AG, Sukovic P (2006) Clinical applications of cone-beam computed tomography in dental practice. J Can Dent Assoc 72, 75-80.
10. 10. Patel S (2009) New dimensions in endodontic imaging: Part 2. Cone beam computed tomography. Int Endod J 42, 463-475.10.1111/j.1365-2591.2008.01531.x ↗
11. 11. Ritter L, Mischkowski RA, Neugebauer J, Dreiseidler T, Scheer M, Keeve E, Zöller JE (2009) The influence of body mass index, age, implants, and dental restorations on image quality of cone beam computed tomography. Oral Surg Oral Med Oral Pathol Oral Radiol Endod 108, e108-116.10.1016/j.tripleo.2009.05.011 ↗
12. 12. Draenert FG, Coppenrath E, Herzog P, Müller S, Mueller-Lisse UG (2007) Beam hardening artefacts occur in dental implant scans with the NewTom cone beam CT but not with the dental 4-row multidetector CT. Dentomaxillofac Radiol 36, 198-203.10.1259/dmfr/32579161 ↗
13. 10.1007/s11547-010-0520-510.1007/s11547-010-0520-5 ↗
14. 10.1067/moe.2003.12010.1067/moe.2003.120 ↗
15. 15. Schulze RK, Berndt D, d’Hoedt B (2010) On cone-beam computed tomography artifacts induced by titanium implants. Clin Oral Implants Res 21, 100-107.10.1111/j.1600-0501.2009.01817.x ↗
16. 16. Liang X, Jacobs R, Hassan B, Li L, Pauwels R, Corpas L, Souza PC, Martens W, Shahbazian M, Alonso A, Lambrichts I (2010) A comparative evaluation of Cone Beam Computed Tomography (CBCT) and Multi-Slice CT (MSCT) Part I. On subjective image quality. Eur J Radiol 75, 265-269.10.1016/j.ejrad.2009.03.042 ↗
17. 17. Lofthag-Hansen S, Thilander-Klang A, Gröndahl K (2011) Evaluation of subjective image quality in relation to diagnostic task for cone beam computed tomography with different fields of view. Eur J Radiol 80, 483-488.10.1016/j.ejrad.2010.09.018 ↗
18. 18. Loubele M, Jacobs R, Maes F, Denis K, White S, Coudyzer W, Lambrichts I, van Steenberghe D, Suetens P (2008) Image quality vs radiation dose of four cone beam computed tomography scanners. Dentomaxillofac Radiol 37, 309-318.10.1259/dmfr/16770531 ↗
19. 19. Sogur E, Baksi BG, Gröndahl HG (2007) Imaging of root canal fillings: a comparison of subjective image quality between limited cone-beam CT, storage phosphor and film radiography. Int Endod J 40, 179-185.10.1111/j.1365-2591.2007.01204.x ↗
20. 20. Lofthag-Hansen S (2009) Cone beam computed tomography radiation dose and image quality assessments. Swed Dent J Suppl, 4-55.
21. 10.1259/dmfr/2342413210.1259/dmfr/23424132 ↗
22. 10.1259/dmfr/1434032310.1259/dmfr/14340323 ↗
23. 10.1016/j.tripleo.2008.03.01810.1016/j.tripleo.2008.03.018 ↗