Clinical indices for orthodontic mini-implants
Source abstract
Abstract
Orthodontic mini-implants were recently developed and have been widely used in clinics. However, loosening of mini-implants, as well as infection and swelling of mucosal tissue at the placement site, are often observed during orthodontic treatment. Thus, clinical indices are greatly needed for the safe use of orthodontic mini-implants. This article presents information on mini-implants and offers suggestions on indications, placement technique, optimum design, and evaluation of the placement site for mini-implants. The author concludes that 1) mini-implants should be left in the placement site for 3 months before loading to allow for a healing period, which increases the success rate in adolescent patients, 2) placement torque should be considered when tightening mini-implants into bone, as excessively high or low torque results in low stability, 3) mini-implants with optimal screws should be placed in the correct position, and 4) a prepared site should be established in an area with a cortical bone thickness of greater than 1.0 mm, to improve the success rate. Finally, the vector of orthodontic forces in the arrangement with the center of resistance of the entire dental arch should be considered when developing treatment goals.
Source: openalex_inverted_index · Quality: baseline
Research context
OpenAlex topics: Orthodontics and Dentofacial Orthopedics · dental development and anomalies · Dental Implant Techniques and Outcomes
SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.
References (28)
Show source-provided references
1. 1. Kanomi R (1997) Mini-implant for orthodontic anchorage. J Clin Orthod 31, 763-767.
2. 10.1034/j.1600-0501.2001.012004358.x10.1034/j.1600-0501.2001.012004358.x ↗
3. 3. Sawa Y, Goto K, Suzuki N, Kamo N, Kamo K (2001) The new method for the maxillary retraction of the anterior teeth using a titanium microscrew as anchorage. Orthod Waves 60, 328-331. (in Japanese)
4. 4. Bae SM, Park HS, Kyung HM, Kwon OW, Sung JH (2002) Clinical application of micro-implant anchorage. J Clin Orthod 36, 298-302.
5. 5. Park HS, Kyung HM, Sung JH (2002) A simple method of molar uprighting with micro-implant anchorage. J Clin Orthod 36, 592-596.
6. 6. Herman RJ, Currier GF, Miyake A (2006) Mini-implant anchorage for maxillary canine retraction: a pilot study. Am J Orthod Dentofacial Orthop 130, 228-235.10.1016/j.ajodo.2006.02.029 ↗
7. 7. Kim TW, Kim H, Lee SJ (2006) Correction of deep overbite and gummy smile by using a mini-implant with a segmented wire in a growing Class II Division 2 patient. Am J Orthod Dentofacial Orthop 130, 676-685.10.1016/j.ajodo.2005.07.013 ↗
8. 8. Costa A, Raffainl M, Melsen B (1998) Miniscrews as orthodontic anchorage: a preliminary report. Int J Adult Orthodon Orthognath Surg 13, 201-209.
9. 9. Kadioglu O, Büyükyilmaz T, Zachrisson BU, Maino BG (2008) Contact damage to root surfaces of premolars touching miniscrews during orthodontic treatment. Am J Orthod Dentofacial Orthop 134, 353-360.10.1016/j.ajodo.2006.09.069 ↗
10. 10. Cho UH, Yu W, Kyung HM (2010) Root contact during drilling for microimplant placement. Affect of surgery site and operator expertise. Angle Orthod 80, 130-136.10.2319/011509-535.1 ↗
11. 10.1016/j.ajodo.2008.07.02610.1016/j.ajodo.2008.07.026 ↗
12. 10.1016/S0889-5406(03)00565-110.1016/S0889-5406(03)00565-1 ↗
13. 13. Motoyoshi M, Hirabayashi M, Uemura M, Shimizu N (2006) Recommended placement torque when tightening an orthodontic mini-implant. Clin Oral Implants Res 17, 109-114.10.1111/j.1600-0501.2005.01211.x ↗
14. 14. Motoyoshi M, Yoshida T, Ono A, Shimizu N (2007) Effect of cortical bone thickness and implant placement torque on stability of orthodontic mini-implant. Int J Oral Maxillofac Implants 22, 779-784.
15. 15. Motoyoshi M, Matsuoka M, Shimizu N (2007) Application of orthodontic mini-implants in adolescents. Int J Oral Maxillofac Surg 36, 695-699.10.1016/j.ijom.2007.03.009 ↗
16. 10.1016/j.ajodo.2005.11.02410.1016/j.ajodo.2005.11.024 ↗
17. 17. Park HS, Lee SK, Kwon OW (2005) Group distal movement of teeth using microscrew implant anchorage. Angle Orthod 75, 602-609.
18. 18. Meredith N (1998) Assessment of implant stability as a prognostic determinant. Int J Prosthodont 11, 491-501.
19. 19. Friberg B, Sennerby L, Gröndahl K, Bergström C, Bäck T, Lekholm U (1999) On cutting torque measurements during implant placement: a 3-year clinical prospective study. Clin Implant Dent Relat Res 1, 75-83.10.1111/j.1708-8208.1999.tb00095.x ↗
20. 20. Motoyoshi M, Uemura M, Ono A, Okazaki K, Shigeeda T, Shimizu N (2010) Factors affecting the long-term stability of orthodontic mini-implants. Am J Orthod Dentofacial Orthop 137, 588.e1-510.1016/j.ajodo.2009.05.019 ↗
21. 10.1007/s00056-006-0611-z10.1007/s00056-006-0611-z ↗
22. 22. Song YY, Cha JY, Hwang CJ (2007) Mechanical characteristics of various orthodontic mini-screws in relation to artificial cortical bone thickness. Angle Orthod 77, 979-985.10.2319/090606-363.1 ↗
23. 23. Okazaki J, Komasa Y, Sakai D, Kamada A, Ikeo T, Toda I, Suwa F, Inoue M, Etoh T (2008) A torque removal study on the primary stability of orthodontic titanium screw mini-implants in the cortical bone of dog femurs. Int J Oral Maxillofac Surg 37, 647-650.10.1016/j.ijom.2008.04.007 ↗
24. 24. Kim SH, Cho JH, Chung KR, Kook YA, Nelson G (2008) Removal torque values of surface-treated mini-implants after loading. Am J Orthod Dentofacial Orthop 134, 36-43.10.1016/j.ajodo.2006.07.038 ↗
25. 25. Yano S, Motoyoshi M, Uemura M, Ono A, Shimizu N (2006) Tapered orthodontic miniscrews induce bone-screw cohesion following immediate loading. Euro J Orthod 28, 541-546.10.1093/ejo/cjl044 ↗
26. 10.1016/j.ijom.2008.01.00510.1016/j.ijom.2008.01.005 ↗
27. 10.1016/j.ajodo.2008.06.03610.1016/j.ajodo.2008.06.036 ↗
28. 28. Motoyoshi M, Shimizu N (2006) Orthodontic treatment using TAD: temporary anchorage devices; placement technique and clinical applications. Quintessence, Tokyo, 37-44. (in Japanese)