journal article·2009Open access

Evaluation of primary stability of inclined orthodontic mini-implants

Mizuki Inaba

Journal of Oral Science· Volume 51· Issue 3

Abstract

The aim of this study was to investigate the initial stability of mini-implants when placed slanting or perpendicular to the bone surface, and to examine the effects of differences in tractional direction. Titanium mini-implants were inserted into rabbit nasal bones, slanting (60 degrees , 120 degrees ) or perpendicular (90 degrees ) to the bone surface. These implants were then loaded with a force of approximately 2 N, using a NiTi coil spring. The mobilities on the traction and non-traction sides were assessed using the Periotest device immediately after placement and after traction for two weeks. Then, the tissues with the mini-implants were resected, and the contact between the bone and the implant was examined by electron microscopy. There was a tendency for the mobilities of the mini-implants at 60 degrees and 120 degrees to be smaller than those at 90 degrees when measured before and after traction. The bone-implant contact lengths at 60 degrees were significantly longer than those at 90 degrees . There was no significant difference in the bone-implant contact ratio among the different angles. Correlations were evident between implant mobility and contact length or contact ratio. It is concluded that in clinical practice, implants inclined to the bone surface tend to have better primary stability.
Source: openalex_inverted_index · Quality: baseline

Research context

OpenAlex topics: Orthodontics and Dentofacial Orthopedics · Temporomandibular Joint Disorders · Dental Implant Techniques and Outcomes

SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.

References (21)

Show source-provided references
1. 1. Costa A, Raffainl M, Melsen B (1998) Miniscrews as orthodontic anchorage: a preliminary report. Int J Adult Orthodon Orthognath Surg 13, 201-209.
2. 2. Park HS, Kwon TG, Kwon OW (2004) Treatment of open bite with microscrew implant anchorage. Am J Orthod Dentofacial Orthop 126, 627-636.10.1016/j.ajodo.2003.07.019 ↗
3. 3. Park HS, Lee SK, Kwon OW (2005) Group distal movement of teeth using microscrew implant anchorage. Angle Orthod 75, 602-609.
4. 4. Ohnishi H, Yagi T, Yasuda Y, Takada K (2005) A mini-implant for orthodontic anchorage in a deep overbite case. Angle Orthod 75, 444-452.
5. 5. Sawa Y, Goto N, Suzuki K, Kamo K (2001) The new method for maxillary retraction of the anterior teeth using a titanium microscrew as anchorage. Nippon Kyosei Shika Gakkai Zasshi 60, 328-331. (in Japanese)
6. 6. Cheng SJ, Tseng IY, Lee JJ, Kok SH (2004) A prospective study of the risk factors associated with failure of mini-implants used for orthodontic anchorage. Int J Oral Maxillofac Implants 19, 100-106.
7. 7. Huja SS, Litsky AS, Beck FM, Johnson KA, Larsen PE (2005) Pull-out strength of monocortical screws placed in the maxillae and mandibles of dogs. Am J Orthod Dentofacial Orthop 127, 307-313.10.1016/j.ajodo.2003.12.023 ↗
8. 8. Wilmes B, Rademacher C, Olthoff G, Drescher D (2006) Parameters affecting primary stability of orthodontic mini-implants. J Orofac Orthop 67, 162-174.10.1007/s00056-006-0611-z ↗
9. 9. Motoyoshi M, Yoshida T, Ono A, Shimizu N (2007) Effect of cortical bone thickness and implant placement torque on stability of orthodontic mini-implants. Int J Oral Maxillofac Implants 22, 779-784.
10. 10.1016/S0889-5406(03)00565-110.1016/S0889-5406(03)00565-1 ↗
11. 11. Deguchi T, Nasu M, Murakami K, Yabuuchi T, Kamioka H, Takano-Yamamoto T (2006) Quantitative evaluation of cortical bone thickness with computed tomographic scanning for orthodontic implants. Am J Orthod Dentofacial Orthop 129, 721.e7-e12.10.1016/j.ajodo.2006.02.026 ↗
12. 12. Klontz HA (1996) Tweed-Merrifield sequential directional force treatment. Semin Orthod 2, 254-267.10.1016/S1073-8746(96)80025-9 ↗
13. 13. Yano S, Motoyoshi M, Uemura M, Ono A, Shimizu N (2006) Tapered orthodontic miniscrews induce bone-screw cohesion following immediate loading. Eur J Orthod 28, 541-546.10.1093/ejo/cjl044 ↗
14. 14. Winkler S, Morris HF, Spray JR (2001) Stability of implants and natural teeth as determined by the Periotest over 60 months of function. J Oral Implantol 27, 198-203.10.1563/1548-1336(2001)027<0198:SOIANT>2.3.CO;2 ↗
15. 15. Canakci V, Orbar R, Tezel A, Canakci CF (2002) Clinical response to experimental forces and non-surgical therapy of teeth with various alveolar bone loss. Dent Traumatol 18, 267-274.10.1034/j.1600-9657.2002.00105.x ↗
16. 16. Andresen M, Mackie I, Worthington H (2003) The Periotest in traumatology. Part I. Does it have the properties necessary for use as a clinical device and can the measurements be interpreted? Dent Traumatol 19, 214-217.
17. 17. Cranin AN, DeGrado J, Kaufman M, Baraoidan M, DiGregorio R, Batgitis G, Lee Z (1998) Evaluation of the Periotest as a diagnotic tool for dental implants. J Oral Implantol 24, 139-146.10.1563/1548-1336(1998)024<0139:EOTPAA>2.3.CO;2 ↗
18. 18. Meredith N, Friberg B, Sennerby L, Aparicio C (1998) Relationship between contact time measurements and PTV values when using the Periotest to measure implant stability. Int J Prosthodont 11, 269-275.
19. 19. Lachmann S, Jäger B, Axmann D, Gomez-Roman G, Groten M, Weber H (2006) Resonance frequency analysis and damping capacity assessment. Part I: an in vitro study on measurement reliability and a method of comparison in the determination of primary dental implant stability. Clin Oral Implants Res 17, 75-79.10.1111/j.1600-0501.2005.01173.x ↗
20. 20. Lioubavina-Hack N, Lang NP, Karring T (2006) Significance of primary stability for osseointegration of dental implants. Clin Oral Implants Res 17, 244-250.10.1111/j.1600-0501.2005.01201.x ↗
21. 21. Olivé J, Aparicio C (1990) Periotest method as a measure of osseointegrated oral implant stability. Int J Oral Maxillofac Implants 5, 390-400.