Polymerization shrinkage kinetics and degree of conversion of resin composites
Source abstract
Abstract
This study compared shrinkage strain, polymerization shrinkage kinetics, and degree of conversion (DC) of a set of resin composites and investigated their influencing factors. Ten commercial resin composites were assessed, and 5 specimens (n = 5) were developed for material and subjected to light curing using light emitting diode light at 650 mW/cm2 for 40 s. The laser triangulation method was adopted to assess the shrinkage strain, and Fourier transform infrared spectroscopy was used to measure DC. The shrinkage strain was monitored for 5 min in real time and its data were subjected to differential calculations to get the shrinkage strain rate curve with respect to time, obtaining the maximum shrinkage strain rate (Rmax) and gel time. The values of shrinkage strain varied from 1.28% to 2.10%. The Rmax values were between 5.17 μm/s and 21.83 μm/s. Gel time values varied from 3.08 s to 4.32 s. The DC yielded values ranging from 53.62% to 87.01%. The values of polymerization shrinkage and DC were dependent on the composition of materials, including the monomer matrix and filler system. Compared to the micro-filler materials, the nano-filler resin composites had higher values of DC. Some resin composites are suitable for clinical applications because of their superior polymerization shrinkage properties and DC.
Source: openalex_inverted_index · Quality: baseline
Research context
OpenAlex topics: Dental materials and restorations · Dental Research and COVID-19 · Orthodontics and Dentofacial Orthopedics
SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.
Affiliations
Department of Prosthodontics, School and Hospital of Stomatology, Jilin University
Department of Dental Materials, School and Hospital of Stomatology, Peking University
Funding
National Natural Science Foundation of China
References (50)
Show source-provided references
1. 1. Bouillaguet S, Wataha JC (2004) Future directions in bonding resins to the dentine-pulp complex. J Oral Rehabil 31, 385-392.10.1046/j.1365-2842.2003.01258.x ↗
2. 2. Tantbirojn D, Versluis A, Pintado MR, DeLong R, Douglas WH (2004) Tooth deformation patterns in molars after composite restoration. Dent Mater 20, 535-542.10.1016/j.dental.2003.05.008 ↗
3. 3. Feilzer AJ, Dooren LH, de Gee AJ, Davidson CL (1995) Influence of light intensity on polymerization shrinkage and integrity of restoration-cavity interface. Eur J Oral Sci 103, 322-326.10.1111/j.1600-0722.1995.tb00033.x ↗
4. 4. Rueggeberg FA (2002) From vulcanite to vinyl, a history of resins in restorative dentistry. J Prosthet Dent 87, 364-379.10.1067/mpr.2002.123400 ↗
5. 5. Dewaele M, Truffier-Boutry D, Devaux J, Leloup G (2006) Volume contraction in photocured dental resins: the shrinkage-conversion relationship revisited. Dent Mater 22, 359-365.10.1016/j.dental.2005.03.014 ↗
6. 6. Stansbury JW, Dickens SH (2001) Determination of double bond conversion in dental resins by near infrared spectroscopy. Dent Mater 17, 71-79.10.1016/S0109-5641(00)00062-2 ↗
7. 7. Baroudi K, Saleh AM, Silikas N, Watts DC (2007) Shrinkage behaviour of flowable resin-composites related to conversion and filler-fraction. J Dent 35, 651-655.10.1016/j.jdent.2007.05.001 ↗
8. 8. Amirouche-Korichi A, Mouzali M, Watts DC (2009) Effects of monomer ratios and highly radiopaque fillers on degree of conversion and shrinkage-strain of dental resin composites. Dent Mater 25, 1411-1418.10.1016/j.dental.2009.06.009 ↗
9. 9. Ribeiro BC, Boaventura JM, Brito-Gonçalves Jd, Rastelli AN, Bagnato VS, Saad JR (2012) Degree of conversion of nanofilled and microhybrid composite resins photo-activated by different generations of LEDs. J Appl Oral Sci 20, 212-217.10.1590/S1678-77572012000200015 ↗
10. 10. Chen MH, Chen CR, Hsu SH, Sun SP, Su WF (2006) Low shrinkage light curable nanocomposite for dental restorative material. Dent Mater 22, 138-145.10.1016/j.dental.2005.02.012 ↗
11. 11. El-Damanhoury H, Platt J (2014) Polymerization shrinkage stress kinetics and related properties of bulk-fill resin composites. Oper Dent 39, 374-382.10.2341/13-017-L ↗
12. 12. Tsujimoto A, Barkmeier WW, Takamizawa T, Latta MA, Miyazaki M (2016) Mechanical properties, volumetric shrinkage and depth of cure of short fiber-reinforced resin composite. Dent Mater J 35, 418-424.10.4012/dmj.2015-280 ↗
13. 13. Reis AF, Vestphal M, Amaral RCD, Rodrigues JA, Roulet JF, Roscoe MG (2017) Efficiency of polymerization of bulk-fill composite resins: a systematic review. Braz Oral Res 31, e59.10.1590/1807-3107bor-2017.vol31.0059 ↗
14. 14. Tsujimoto A, Barkmeier WW, Takamizawa T, Latta MA, Miyazaki M (2017) Depth of cure, flexural properties and volumetric shrinkage of low and high viscosity bulk-fill giomers and resin composites. Dent Mater J 36, 205-213.10.4012/dmj.2016-131 ↗
15. 15. Benetti AR, Havndrup-Pedersen C, Honoré D, Pedersen MK, Pallesen U (2015) Bulk-fill resin composites: polymerization contraction, depth of cure, and gap formation. Oper Dent 40, 190-200.10.2341/13-324-L ↗
16. 16. Haas KH, Wolter H (1999) Synthesis, properties and applications of inorganic–organic copolymers (ORMOCER®s). Curr Opin Solid State Mater Sci 4, 571-580.10.1016/S1359-0286(00)00009-7 ↗
17. 17. Terry DA, Leinfelder KF, Blatz MB (2009) A comparison of advanced resin monomer technologies. Dent Today 28, 122-123.
18. 18. Barnes DM, Blank LW, Gingell JC, Gilner PP (1995) A clinical evaluation of a resin-modified. Glass ionomer restorative material. J Am Dent Assoc 126, 1245-1253.10.14219/jada.archive.1995.0359 ↗
19. 19. Pitel ML (2013) Low-shrink composite resins: a review of their history, strategies for managing shrinkage, and clinical significance. Compend Contin Educ Dent 34, 578-590.
20. 20. Mitra SB, Wu D, Holmes BN (2003) An application of nanotechnology in advanced dental materials. J Am Dent Assoc 134, 1382-1390.10.14219/jada.archive.2003.0054 ↗
21. 21. Gao BT, Lin H, Zheng G, Xu YX, Yang JL (2012). Comparison between a silorane-based composite and methacrylate-based composites: shrinkage characteristics, thermal properties, gel point and vitrification point. Dent Mater J 31, 76-85.10.4012/dmj.2011-147 ↗
22. 22. de Gee AF, Feilzer AJ, Davidson CL (1993) True linear polymerization shrinkage of unfilled resins and composites determined with a linometer. Dent Mater 9, 11-14.10.1016/0109-5641(93)90097-A ↗
23. 23. Fano L, Ma WY, Marcoli PA, Pizzi S, Fano V (2002) Polymerization of dental composite resins using plasma light. Biomaterials 23, 1011-1015.10.1016/S0142-9612(01)00212-5 ↗
24. 24. Rueggeberg FA, Caughman WF, Curtis JW Jr (1994) Effect of light intensity and exposure duration on cure of resin composite. Oper Dent 19, 26-32.
25. 25. Ilie N, Hickel R (2011) Resin composite restorative materials. Aust Dent J 56 Suppl1, 59-66.10.1111/j.1834-7819.2010.01296.x ↗
26. 26. Al Sunbul H, Silikas N, Watts DC (2016) Polymerization shrinkage kinetics and shrinkage-stress in dental resin-composites. Dent Mater 32, 998-1006.10.1016/j.dental.2016.05.006 ↗
27. 27. Braga RR, Ballester RY, Ferracane JL (2005) Factors involved in the development of polymerization shrinkage stress in resin-composites: a systematic review. Dent Mater 21, 962-970.10.1016/j.dental.2005.04.018 ↗
28. 28. Satterthwaite JD, Vogel K, Watts DC (2009) Effect of resin-composite filler particle size and shape on shrinkage–strain. Dent Mater 25, 1612-1615.10.1016/j.dental.2009.08.012 ↗
29. 29. Shibasaki S, Takamizawa T, Nojiri K, Imai A, Tsujimoto A, Endo H et al. (2017) Polymerization behavior and mechanical properties of high-viscosity bulk fill and low shrinkage resin composites. Oper Dent 42, E177-E187.10.2341/16-385-L ↗
30. 30. Lee CH, Ferracane J, Lee IB (2018) Effect of pulse width modulation-controlled LED light on the polymerization of dental composites. Dent Mater 34, 1836-1845.10.1016/j.dental.2018.10.003 ↗
31. 31. Tauböck TT, Jäger F, Attin T (2019) Polymerization shrinkage and shrinkage force kinetics of high- and low-viscosity dimethacrylate- and ormocer-based bulk-fill resin composites. Odontology 107, 103-110.10.1007/s10266-018-0369-y ↗
32. 32. Sideridou ID, Vouvoudi EC, Adamidou EA (2015) Dynamic mechanical thermal properties of the dental light-cured nanohybrid composite Kalore, GC: effect of various food/oral simulating liquids. Dent Mater 31, 154-161.10.1016/j.dental.2014.11.008 ↗
33. 33. Ferracane JL (2005) Developing a more complete understanding of stresses produced in dental composites during polymerization. Dent Mater 21, 36-42.10.1016/j.dental.2004.10.004 ↗
34. 34. Kinomoto Y, Torii M, Takeshige F, Ebisu S (1999) Comparison of polymerization contraction stresses between self- and light-curing composites. J Dent 27, 383-389.10.1016/S0300-5712(98)00065-7 ↗
35. 35. Lovell LG, Stansbury JW, Syrpes DC, Bowman CN (1999) Effects of composition and reactivity on the reaction kinetics of dimethacrylate/dimethacrylate copolymerizations. Macromolecules 32, 3913-3921.10.1021/ma990258d ↗
36. 36. Anseth KS, Wang CM, Bowman CN (1994) Kinetic evidence of reaction diffusion during the polymerization of multi(meth)acrylate monomer. Macromolecules 27, 650-655.10.1021/ma00081a004 ↗
37. 37. Atai M, Watts DC, Atai Z (2005) Shrinkage strain-rates of dental resin-monomer and composite systems. Biomaterials 26, 5015-5020.10.1016/j.biomaterials.2005.01.022 ↗
38. 38. Durner J, Schrickel K, Watts DC, Ilie N (2015) Determination of homologous distributions of bisEMA dimethacrylates in bulk-fill resin-composites by GC-MS. Dent Mater 31, 473-480.10.1016/j.dental.2015.02.006 ↗
39. 39. Yu P, Yap A, Wang XY (2017) Degree of conversion and polymerization shrinkage of bulk-fill resin-based composites. Oper Dent 42, 82-89.10.2341/16-027-L ↗
40. 40. Suzuki N, Zakaria MB, Chiang YD, Wu KC, Yamauchi Y (2012) Thermally stable polymer composites with improved transparency by using colloidal mesoporous silica nanoparticles as inorganic fillers. Phys Chem Chem Phys 14, 7427-7432.10.1039/c2cp40356k ↗
41. 41. Karabela MM, Sideridou ID (2011) Synthesis and study of properties of dental resin composites with different nanosilica particles size. Dent Mater 27, 825-835.10.1016/j.dental.2011.04.008 ↗
42. 42. Liu X, Wang Z, Zhao C, Bu W, Na H (2018) Preparation and characterization of silane-modified SiO2 particles reinforced resin composites with fluorinated acrylate polymer. J Mech Behav Biomed Mater 80, 11-19.10.1016/j.jmbbm.2018.01.004 ↗
43. 43. Lempel E, Czibulya Z, Kovács B, Szalma J, Tóth Á, Kunsági-Máté S et al. (2016) Degree of conversion and BisGMA, TEGDMA, UDMA elution from flowable bulk fill composites. Int J Mol Sci 17,732.10.3390/ijms17050732 ↗
44. 44. Gonçalves F, Kawano Y, Pfeifer C, Stansbury JW, Braga RR. (2009) Influence of BisGMA, TEGDMA, and BisEMA contents on viscosity, conversion, and flexural strength of experimental resins and composites. Eur J Oral Sci 117, 442-446.10.1111/j.1600-0722.2009.00636.x ↗
45. 45. Sideridou I, Tserki V, Papanastasiou G (2002) Effect of chemical structure on degree of conversion in light-cured dimethacrylate-based dental resins. Biomaterials 23, 1819-1829.10.1016/S0142-9612(01)00308-8 ↗
46. 46. Bala O, Olmez A, Kalayci S (2005) Effect of LED and halogen light curing on polymerization of resin-based composites. J Oral Rehabil 32, 134-140.10.1111/j.1365-2842.2004.01399.x ↗
47. 47. Atai M, Nekoomanesh M, Hashemi SA, Amani S (2004) Physical and mechanical properties of an experimental dental composite based on a new monomer. Dent Mater 20, 663-668.10.1016/j.dental.2003.08.008 ↗
48. 48. Gonçalves L, Filho JD, Guimarães JG, Poskus LT, Silva EM (2008) Solubility, salivary sorption and degree of conversion of dimethacrylate-based polymeric matrixes. J Biomed Mater Res B Appl Biomater 85, 320-325.10.1002/jbm.b.30949 ↗
49. 49. Liu D, Liu F, He J, Lassila LV, Vallittu PK (2013) Synthesis of a novel tertiary amine containing urethane dimethacrylate monomer (UDMTA) and its application in dental resin. J Mater Sci Mater Med 24, 1595-1603.10.1007/s10856-013-4897-2 ↗
50. 50. Hong L, Wang Y, Wang L, Zhang H, Na H, Zhang Z (2017) Synthesis and characterization of a novel resin monomer with low viscosity. J Dent 59, 11-17.10.1016/j.jdent.2017.01.006 ↗