We evaluated the curing efficiency of 4 high-intensity light-emitting diode (LED) devices by assessing percentage of residual C=C (%RDB), surface microhardness (SM), depth of cure (DC), percentage of linear shrinkage-strain (%LS), and percentage of wall-to-wall contraction (%WWC). The light-curing units tested were a QTH light, the Elipar TriLight (3M/ESPE), and 4 LED devices - the Allegro (Denmat), the Bluephase (Ivoclar/Vivadent), the FreeLight2 (3M/ESPE), and The Cure TC-01 (Spring Health Products). The %RDB was measured by microFTIR spectroscopy. Microhardness measurements (Vickers) were performed at the surface (H0) and at depths of 3 mm (H3) and 5 mm (H5) of cylindrical specimens. Depth of cure was expressed as the ratio of microhardness at each depth, relative to the corresponding surface value (H3/H0 and H5/H0). The bonded disc method was used to evaluate %LS. For the %WWC evaluation, cylindrical resin restorations were imaged by high resolution micro-CT and the %WWC was calculated at depths of 0 mm and 2 mm. There were no statistical differences among the LEDs in %RDB or %LS. The Bluephase and Allegro had the highest SM values. As compared with the other LEDs, the Bluephase and The Cure TC-01 had lower values for depth of cure at depths of 3 mm and 5 mm. There were no significant differences in %WWC among the LEDs at either depth, and the QTH had the lowest %WWC at both depths.
Source: openalex_inverted_index · Quality: baseline

Research context

OpenAlex topics: Dental materials and restorations · Photopolymerization techniques and applications · Dental Erosion and Treatment

SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.

References (45)

Show source-provided references
1. 10.1016/S0142-9612(02)00585-910.1016/S0142-9612(02)00585-9 ↗
2. 10.1046/j.1365-2842.2002.00970.x10.1046/j.1365-2842.2002.00970.x ↗
3. 10.1002/jbm.1039010.1002/jbm.10390 ↗
4. 10.1016/S0109-5641(99)00083-410.1016/S0109-5641(99)00083-4 ↗
5. 10.1016/S0109-5641(03)00070-810.1016/S0109-5641(03)00070-8 ↗
6. 10.1016/S0109-5641(03)00095-210.1016/S0109-5641(03)00095-2 ↗
7. 7. Lindberg A, Peutzfeldt A, Van Dijken JWV (2004) Curing depths of a universal hybrid and a flowable resin composite cured with quartz tungsten halogen and light-emitting diode units. Acta Odontol Scand 62, 97-101.10.1080/00016350410006905 ↗
8. 10.1046/j.1365-2842.2001.00709.x10.1046/j.1365-2842.2001.00709.x ↗
9. 10.1034/j.1600-0722.2002.21359.x10.1034/j.1600-0722.2002.21359.x ↗
10. 10.1016/S0142-9612(00)00029-610.1016/S0142-9612(00)00029-6 ↗
11. 10.1111/j.0909-8836.2004.00092.x10.1111/j.0909-8836.2004.00092.x ↗
12. 12. Krämer N, Lohbauer U, García-Godoy F, Frankenberger R (2008) Light curing of resin-based composites in the LED era. Am J Dent 21, 135-142.
13. 13. Watts DC, Cash AJ (1991) Determination of polymerization shrinkage kinetics in visible-light-cured materials: methods development. Dent Mater 7, 281-287.10.1016/S0109-5641(05)80030-2 ↗
14. 10.1016/S0109-5641(05)80005-310.1016/S0109-5641(05)80005-3 ↗
15. 10.1002/jbm.82020011110.1002/jbm.820200111 ↗
16. 10.1016/j.dental.2004.03.01010.1016/j.dental.2004.03.010 ↗
17. 10.1016/S0142-9612(02)00024-810.1016/S0142-9612(02)00024-8 ↗
18. 18. Cunha LG, Alonso RC, Neves AC, de Goes MF, Ferracane JL, Sinhoreti MA (2009) Degree of conversion and contraction stress development of a resin composite irradiated using halogen and LED at two C-factor levels. Oper Dent 34, 24-31.10.2341/08-32 ↗
19. 19. Atai M, Motevasselian F (2009) Temperature rise and degree of photopolymerization conversion of nanocomposites and conventional dental composites. Clin Oral Investig 13, 309-316.10.1007/s00784-008-0236-2 ↗
20. 20. Soh MS, Yap AU, Yu T, Shen ZX (2004) Analysis of the degree of conversion of LED and halogen lights using micro-Raman spectroscopy. Oper Dent 29, 571-577.
21. 21. Santos GB, Medeiros IS, Fellows CE, Muench A, Braga RR (2007) Composite depth of cure obtained with QTH and LED units assessed by microhardness and micro-Raman spectroscopy. Oper Dent 32, 79-83.10.2341/06-26 ↗
22. 10.1111/j.1708-8240.2002.tb00524.x10.1111/j.1708-8240.2002.tb00524.x ↗
23. 10.1002/jbm.10126.abs10.1002/jbm.10126.abs ↗
24. 10.1016/j.dental.2004.10.00310.1016/j.dental.2004.10.003 ↗
25. 10.1007/s00784-005-0312-910.1007/s00784-005-0312-9 ↗
26. 10.1016/S0300-5712(97)00004-310.1016/S0300-5712(97)00004-3 ↗
27. 27. Wiggins KM, Hartung M, Althoff O, Wastian C, Mitra SB (2004) Curing performance of a new-generation light-emitting diode dental curing unit. J Am Dent Assoc 135, 1471-1479.10.14219/jada.archive.2004.0059 ↗
28. 28. Ceballos L, Fuentes MV, Tafalla H, Martínez A, Flores J, Rodríguez J (2009) Curing effectiveness of resin composites at different exposure times using LED and halogen units. Med Oral Patol Oral Cir Bucal 14, E51-E56.
29. 29. Cefaly DF, Ferrarezi GA, Tapety CM, Lauris JR, Navarro MF (2005) Microhardness of resin-based materials polymerized with LED and halogen curing units. Braz Dent J 16, 98-102.10.1590/S0103-64402005000200002 ↗
30. 30. Peris AR, Mitsui FH, Amaral CM, Ambrosano GM, Pimenta LA (2005) The effect of composite type on microhardness when using quartz-tungsten-halogen (QTH) or LED lights. Oper Dent 30, 649-654.
31. 31. Alpöz AR, Ertugrul F, Cogulu D, Ak AT, Tanoglu M, Kaya E (2008) Effects of light curing method and exposure time on mechanical properties of resin based dental materials. Eur J Dent 2, 37-42.10.1055/s-0039-1697351 ↗
32. 10.1016/0109-5641(92)90104-K10.1016/0109-5641(92)90104-K ↗
33. 33. Fleming GJ, Awan M, Cooper PR, Sloan AJ (2008) The potential of a resin-composite to be cured to a 4mm depth. Dent Mater 24, 522-529.10.1016/j.dental.2007.05.016 ↗
34. 10.1016/S0300-5712(99)00014-710.1016/S0300-5712(99)00014-7 ↗
35. 35. Calheiros FC, Daronch M, Rueggeberg FA, Braga RR (2008) Influence of irradiant energy on degree of conversion, polymerization rate and shrinkage stress in an experimental resin composite system. Dent Mater 24, 1164-1168.10.1016/j.dental.2008.01.006 ↗
36. 36. Ernst CP, Meyer GR, Müller J, Stender E, Ahlers MO, Willershausern B (2004) Depth of cure of LED vs QTH light-curing devices at a distance of 7 mm. J Adhes Dent 6, 141-150.
37. 37. Polydorou O, Manolakis A, Hellwig E, Hahn P (2008) Evaluation of the curing depth of two translucent composite materials using a halogen and two LED curing units. Clin Oral Investig 12, 45-51.10.1007/s00784-007-0142-z ↗
38. 10.1016/j.biomaterials.2005.01.02210.1016/j.biomaterials.2005.01.022 ↗
39. 10.1016/S0109-5641(00)00079-810.1016/S0109-5641(00)00079-8 ↗
40. 40. Kakaboura A, Rahiotis C, Watts D, Silikas N, Eliades G (2007) 3D-marginal adaptation versus setting shrinkage in light-cured microhybrid resin composites. Dent Mater 23, 272-278.10.1016/j.dental.2006.01.020 ↗
41. 41. Sakaguchi RL, Wiltbank BD, Murchison CF (2004) Prediction of composite elastic modulus and polymerization shrinkage by computational micromechanics. Dent Mater 20, 397-401.10.1016/j.dental.2003.11.003 ↗
42. 42. Sakaguchi RL, Wiltbank BD, Shah NC (2004) Critical configuration analysis of four methods for measuring polymerization shrinkage strain of composites. Dent Mater 20, 388-396.10.1016/j.dental.2003.11.002 ↗
43. 43. Hansen EK (1982) Visible light-cured composite resins: polymerization contraction, contraction pattern and hygroscopic expansion. Scand J Dent Res 90, 329-335.10.1111/j.1600-0722.1982.tb00745.x ↗
44. 10.1016/j.dental.2004.08.00710.1016/j.dental.2004.08.007 ↗
45. 45. D'Alpino PH, Svizero NR, Pereira JC, Rueggeberg FA, Carvalho RM, Pashley DH (2007) Influence of light-curing sources on polymerization reaction kinetics of a restorative system. Am J Dent 20, 46-52.