A comparative SEM investigation of the smear layer following preparation of root canals using nickel titanium rotary and hand instruments
Source abstract
Abstract
The aim of this study was to compare the efficacy of NiTi flex K-file instruments and rotary FlexMaster and Race instruments (short for reamers with Alternating Cutting Edges) in root canal preparation. A total of 75 single rooted teeth with minimum curvature (< 5 degrees ) were selected and divided into three groups, each containing 25 teeth. Canals were prepared with NiTi flex K-file, FlexMaster and Race instruments using crown down preparation technique, up to size #40. After each instrument, the root canals were flushed with 5 ml of 0.5% NaOCl solution. The amount of debris and smear layer was quantified on the basis of Hulsmann method using a scanning electron microscope. Completely cleaned root canals were not found after instrumentation with any of the three instruments. In general, FlexMaster instruments left significantly less debris and smear layer than Race and NiTi flex K-file instruments (P < 0.05). NiTi flex K-files resulted in significantly more smear layer (P < 0.05) compared to Race and FlexMaster instruments only in the apical third of the canal.
Source: openalex_inverted_index · Quality: baseline
Research context
OpenAlex topics: Endodontics and Root Canal Treatments · Dental Radiography and Imaging · Dental materials and restorations
SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.
References (17)
Show source-provided references
1. 1. Bolanos OR, Jensen JR (1980) Scanning electron microscope comparisons of the efficacy of various methods of root canal preparation. J Endod 6, 815-82210.1016/S0099-2399(80)80034-3 ↗
2. 2. European Society of Endodontology (1994) Consensus report of the European Society of Endodontology on quality guidelines for endodontic treatment. Int Endod J 27, 115-12410.1111/j.1365-2591.1994.tb00240.x ↗
3. 3. Cohen S, Hargreaves KM (2006) Pathways of the pulp. 9th ed, Mosby, St Louis, 260, 365-367
4. 4. Hulsmann M, Rummelin C, Schafers F (1997) Root canal cleanliness after preparation with different endodontic handpieces and hand instruments: a comparative SEM investigation. J Endod 23, 301-30610.1016/S0099-2399(97)80410-4 ↗
5. 5. Thompson SA, Dummer PM (1997) Shaping ability of ProFile.04 Taper Series 29 rotary nickel-titanium instruments in simulated root canals. Part 1. Int Endod J 30, 1-710.1111/j.1365-2591.1997.tb01093.x ↗
6. 6. Thompson SA, Dummer PM (1997) Shaping ability of ProFile.04 Taper Series 29 rotary nickel-titanium instruments in simulated root canals. Part 2. Int Endod J 30, 8-1510.1111/j.1365-2591.1997.tb01092.x ↗
7. 7. Mounce RE (2004) Does NiTi Nirvana exist? Contemp Endod 1, 8-13
8. 8. Schafer E, Lohmann D (2002) Efficiency of rotary nickel-titanium FlexMaster instruments compared with stainless steel hand K-Flexofile - Part 2. Cleaning effectiveness and instrumentation results in severely curved root canals of extracted teeth. Int Endod J 35, 514-52110.1046/j.1365-2591.2002.00515.x ↗
9. 9. Schneider SW (1971) A comparison of canal preparations in straight and curved root canals. Oral Surg Oral Med Oral Pathol 32, 271-27510.1016/0030-4220(71)90230-1 ↗
10. 10. Suffridge CB, Hartwell GR, Walker TL (2003) Cleaning efficiency of nickel-titanium GT and .04 rotary files when used in a torque-controlled rotary handpiece. J Endod 29, 346-34810.1097/00004770-200305000-00007 ↗
11. 11. Kum KY, Kazemi RB, Cha BY, Zhu Q (2006) Smear layer production of K3 and ProFile Ni-Ti rotary instruments in curved root canals: a comparative SEM study. Oral Surg Oral Med Oral Pathol Oral Radiol Endod 101, 536-54110.1016/j.tripleo.2005.02.079 ↗
12. 12. Sonntag D, Delschen S, Stachniss V (2003) Root-canal shaping with manual and rotary Ni-Ti files performed by students. Int Endod J 36, 715-72310.1046/j.1365-2591.2003.00703.x ↗
13. 13. Baumann MA (2002) The RaCe system: a promising new approach for root canal treatment with nickel-titanium files. Germ J Dent, spec iss 12/01
14. 14. Mizrahi SJ, Tucker JW, Seltzer S (1975) A scanning electron microscopic study of the efficacy of various endodontic instruments. J Endod 1, 324-33310.1016/S0099-2399(75)80012-4 ↗
15. 15. Spangberg L, Engstrom B, Langeland K (1973) Biologic effects of dental materials. 3. Toxicity and antimicrobial effect of endodontic antiseptics in vitro. Oral Surg Oral Med Oral Pathol 36, 856-87110.1016/0030-4220(73)90338-1 ↗
16. 10.1016/0030-4220(83)90333-X10.1016/0030-4220(83)90333-X ↗
17. 17. Schafer E, Zapke K (2000) A comparative scanning electron microscopic investigation of the efficacy of manual and automated instrumentation of root canals. J Endod 26, 600-60410.1097/00004770-200011000-00007 ↗