journal article·2014Open access

Comparison of cyclic fatigue and torsional resistance in reciprocating single-file systems and continuous rotary instrumentation systems

Matheus F. da Frota, Camila G. Espir, Fábio L. C. V. Berbert, André A. F. Marques, Emílio C. Sponchiado-Junior, Mario Tanomaru-Filho, Lucas F. R. Garcia, Idomeo Bonetti-Filho

Journal of Oral Science· Volume 56· Issue 4

Abstract

As compared with continuous rotary systems, reciprocating motion is believed to increase the fatigue resistance of NiTi instruments. We compared the cyclic fatigue and torsional resistance of reciprocating single-file systems and continuous rotary instrumentation systems in simulated root canals. Eighty instruments from the ProTaper Universal, WaveOne, MTwo, and Reciproc systems (n = 20) were submitted to dynamic bending testing in stainless-steel simulated curved canals. Axial displacement of the simulated canals was performed with half of the instruments (n = 10), with back-and-forth movements in a range of 1.5 mm. Time until fracture was recorded, and the number of cycles until instrument fracture was calculated. Cyclic fatigue resistance was greater for reciprocating systems than for rotary systems (P < 0.05). Instruments from the Reciproc and WaveOne systems significantly differed only when axial displacement occurred (P < 0.05). Instruments of the ProTaper Universal and MTwo systems did not significantly differ (P > 0.05). Cyclic fatigue and torsional resistance were greater for reciprocating systems than for continuous rotary systems, irrespective of axial displacement.
Source: openalex_inverted_index · Quality: baseline

Research context

OpenAlex topics: Endodontics and Root Canal Treatments · Occupational health in dentistry

SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.

References (25)

Show source-provided references
1. 1. Versiani MA, Leoni GB, Steier L, De-Deus G, Tassani S, Pécora JD et al. (2013) Micro-computed tomography study of oval-shaped canals prepared with the self-adjusting file, Reciproc, WaveOne, and ProTaper universal systems. J Endod 39, 1060-1066.10.1016/j.joen.2013.04.009 ↗
2. 2. Yoshimine Y, Ono M, Akamine A (2005) The shaping effects of three nickel-titanium rotary instruments in simulated S-shaped canals. J Endod 31, 373-375.10.1097/01.don.0000140568.40462.43 ↗
3. 3. Lopes HP, Moreira EJL, Elias CN, de Almeida RA, Neves MS (2007) Cyclic fatigue of ProTaper instruments. J Endod 33, 55-57.10.1016/j.joen.2006.09.003 ↗
4. 4. Plotino G, Grande NM, Cordaro M, Testarelli L, Gambarini G (2009) A review of cyclic fatigue testing of nickel-titanium rotary instruments. J Endod 35, 1469-1476.10.1016/j.joen.2009.06.015 ↗
5. 5. Martín B, Zelada G, Varela P, Bahillo JG, Magán F, Ahn S et al. (2003) Factors influencing the fracture of nickel-titanium rotary instruments. Int Endod J 36, 262-266.10.1046/j.1365-2591.2003.00630.x ↗
6. 6. Di Fiore PM (2007) A dozen ways to prevent nickel-titanium rotary instrument fracture. J Am Dent Assoc 138, 196-201.10.14219/jada.archive.2007.0136 ↗
7. 7. Ounsi HF, Salameh Z, Al-Shalan T, Ferrari M, Grandini S, Pashley DH et al. (2007) Effect of clinical use on the cyclic fatigue resistance of ProTaper nickel-titanium rotary instruments. J Endod 33, 737-741.10.1016/j.joen.2007.03.006 ↗
8. 8. Franco V, Fabiani C, Taschieri S, Malentacca A, Bortolin M, Del Fabbro M (2011) Investigation on the shaping ability of nickel-titanium files when used with a reciprocating motion. J Endod 37, 1398-1401.10.1016/j.joen.2011.06.030 ↗
9. 9. Al-Hadlaq SM, Aljarbou FA, AlThumairy RI (2010) Evaluation of cyclic flexural fatigue of M-wire nickel-titanium rotary instruments. J Endod 36, 305-307.10.1016/j.joen.2009.10.032 ↗
10. 10. De-Deus G, Moreira EJ, Lopes HP, Elias CN (2010) Extended cyclic fatigue life of F2 ProTaper instruments used in reciprocating movement. Int Endod J 43, 1063-1068.10.1111/j.1365-2591.2010.01756.x ↗
11. 11. Kim HC, Kwak SW, Cheung GSP, Ko DH, Chung SM, Lee WC (2012) Cyclic fatigue and torsional resistance of two new nickel-titanium instruments used in reciprocation motion: reciproc versus WaveOne. J Endod 38, 541-544.10.1016/j.joen.2011.11.014 ↗
12. 12. Plotino G, Grande NM, Testarelli L, Gambarini G (2012) Cyclic fatigue of Reciproc and WaveOne reciprocating instruments. Int Endod J 45, 614-618.10.1111/j.1365-2591.2012.02015.x ↗
13. 13. Spanaki-Voreadi AP, Kerezoudis NP, Zinelis S (2006) Failure mechanism of ProTaper Ni-Ti rotary instruments during clinical use: fractographic analysis. Int Endod J 39, 171-178.10.1111/j.1365-2591.2006.01065.x ↗
14. 14. Kosti E, Zinelis S, Molyvdas I, Lambrianidis T (2011) Effect of root canal curvature on the failure incidence of ProFile rotary Ni-Ti endodontic instruments. Int Endod J 44, 917-925.10.1111/j.1365-2591.2011.01900.x ↗
15. 15. Yared G (2008) Canal preparation using only one Ni-Ti rotary instrument: preliminary observations. Int Endod J 41, 339-344.10.1111/j.1365-2591.2007.01351.x ↗
16. 16. Hülsmann M, Peters OA, Dummer PMH (2005) Mechanical preparation of root canals: shaping goals, techniques and means. Endod Topics 10, 30-76.10.1111/j.1601-1546.2005.00152.x ↗
17. 17. Gambarini G, Grande NM, Plotino G, Somma F, Garala M, De Luca M et al. (2008) Fatigue resistance of engine-driven rotary nickel-titanium instruments produced by new manufacturing methods. J Endod 34, 1003-1005.10.1016/j.joen.2008.05.007 ↗
18. 18. Pedullà E, Grande NM, Plotino G, Gambarini G, Rapisarda E (2013) Influence of continuous or reciprocating motion on cyclic fatigue resistance of 4 different nickel-titanium rotary instruments. J Endod 39, 258-261.10.1016/j.joen.2012.10.025 ↗
19. 19. Gambarini G, Plotino G, Grande NM, Al-Sudani D, De Luca M, Testarelli L (2011) Mechanical properties of nickel-titanium rotary instruments produced with a new manufacturing technique. Int Endod J 44, 337-341.10.1111/j.1365-2591.2010.01835.x ↗
20. 20. Inan U, Aydin C, Uzun O, Topuz O, Alacam T (2007) Evaluation of the surface characteristics of used and new ProTaper instruments: an atomic force microscopy study. J Endod 33, 1334-1337.10.1016/j.joen.2007.07.014 ↗
21. 21. Li UM, Lee BS, Shih CT, Lan WH, Lin CP (2002) Cyclic fatigue of endodontic nickel titanium rotary instruments: static and dynamic tests. J Endod 28, 448-451.10.1097/00004770-200206000-00007 ↗
22. 22. Gavini G, Caldeira CL, Akisue E, Candeiro GT, Kawakami DA (2012) Resistance to flexural fatigue of Reciproc R25 files under continuous rotation and reciprocating movement. J Endod 38, 684-687.10.1016/j.joen.2011.12.033 ↗
23. 23. Bürklein S, Hinschitza K, Dammaschke T, Schäfer E (2012) Shaping ability and cleaning effectiveness of two single-file systems in severely curved root canals of extracted teeth: Reciproc and WaveOne versus Mtwo and ProTaper. Int Endod J 45, 449-461.10.1111/j.1365-2591.2011.01996.x ↗
24. 24. Sattapan B, Palamara JEA, Messer HH (2000) Torque during canal instrumentation using rotary nickel-titanium files. J Endod 26, 156-160.10.1097/00004770-200003000-00007 ↗
25. 25. Vaidyanathan R, Dunand DC, Ramamurty U (2000) Fatigue crack-growth in shape-memory NiTi and NiTi-TiC composites. Mater Sci Eng A 289, 208-216.10.1016/S0921-5093(00)00882-0 ↗