The influence of temperature on sheet lamination process when fabricating mouthguard on dental thermoforming machine
Source abstract
Abstract
Laminated custom-made mouthguards tend to delaminate with use; this is a problem in clinical use. Insufficient bonding strength causes delamination, and bonding strength is strongly affected by heating temperature during lamination. The present study aimed to evaluate the influence of heating temperature on the sheet lamination process. Seven mouthguard sheet products were laminated together at different heating temperatures. To evaluate the bonding strength, a delamination test (n = 6) was performed, and the fracture patterns were inspected visually. To evaluate the shock absorption capability, a falling impact test (n = 5) was performed, and the specimen thicknesses were measured. All recorded values were analyzed using two-way analysis of variance and Tukey's Honest Significant Difference Test (P < 0.05). The present study confirmed that bonding strength was dependent on heating temperature: In ethylene-vinyl acetate copolymer products, the bonding strength was almost constant at 130°C and above, and it was constant at 110°C and above in polyolefin products. The thickness of every specimen decreased and, in some specimens, the shock absorption capability decreased with increasing heating temperature. The present study concludes that the heating temperature during the sheet lamination process when laminated custom-made mouthguards are fabricated may not be less than 120°C in ethylene-vinyl acetate copolymer products and 110°C in polyolefin products.
Source: openalex_inverted_index · Quality: baseline
Research context
OpenAlex topics: Dental Trauma and Treatments · Dental materials and restorations · Dental Implant Techniques and Outcomes
SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.
Affiliations
Department of Sports medicine/ Dentistry, Graduate School of Medical and Dental Science, Tokyo Medical and Dental University
Department of Advanced Biomaterials, Graduate School of Medical and Dental Science, Tokyo Medical and Dental University
Department of Oral Biomaterials Development Engineering, Graduate School of Medical and Dental Science, Tokyo Medical and Dental University
References (20)
Show source-provided references
1. 1. ADA Council on Access Prevention and Interprofessional Relations ADA Coundcil on Scientific Affairs (2006) Using mouthguards to reduce the incidence and severity of sports-related oral injuries. J Am Dent Assoc 137, 1712-1720.10.14219/jada.archive.2006.0118 ↗
2. 3. Westerman B, Stringfellow PM, Eccleston JA (2002) EVA mouthguards: how thick should they be? Dent Traumatol 18, 24-27.10.1034/j.1600-9657.2002.180103.x ↗
3. 4. C McClelland, M Kinirons, L Geary (1999) A preliminary study of patient comfort associated with customised mouthguards. Br J Sports Med 33, 186-189.10.1136/bjsm.33.3.186 ↗
4. 5. Takahashi M, Koide K, Mizuhashi F (2013) Variation in mouthguard thickness due to different heating conditions during fabrication. J Prosthodont Res 57, 179-185.10.1016/j.jpor.2013.04.002 ↗
5. 6. Fukasawa S, Churei H, Chowdhury R U, Shirako T, Sharin S, Shrestha A et al.(2016) Difference among shock-absorbing capabilities of mouthguard materials. Dent Traumatol 32, 474-479.10.1111/edt.12275 ↗
6. 7. Kawarai C, Satoh N, Matsumoto M, Yasui T (2002) Effect of heating temperature on mouthguard fittings. J Sports Dent 5, 25-29.
7. 8. Takahashi M, Koide K, Suzuki H, Iwasaki S (2016) Optimal heating condition of ethylene vinyl acetate co-polymer mouthguard sheet in vacuum-pressure formation. Dent Traumatol 32, 311-315.10.1111/edt.12248 ↗
8. 9. Yamada J, Maeda Y (2007) Thermoforming process for fabricating oral appliances: influence of heating and pressure application timing on formability. J Prosthodont 16, 452-456.10.1111/j.1532-849X.2007.00222.x ↗
9. 10. Maeda M, Takeda T, Nakajima K, Shibusawa M, Kurokawa K, Shimada A et al. (2008) In search of necessary mouthguard thickness. Part 1: from the viewpoint of shock absorption ability. J Jpn Prosthodont Soc 52, 211-219.10.2186/jjps.52.211 ↗
10. 11. Reza F, Churei H, Takahashi H, Iwasaki N, Ueno T (2014) Flexural impact force absorption of mouthguard materials using film sensor system. Dent Traumatol 30, 193-197.10.1111/edt.12068 ↗
11. 12. International Organization for Standardization (2011) Rubber, vulcanized or thermoplastics-determination of tensile stress-strain properties. ISO 37:2011, Geneve.
12. 13. Suzuki H, Harashima T, Asano T, Komiyama O, Kuroki T, Kusaka K et al. (2007) Use of polyolefin as mouthguard material as compared to ethylene vinyl acetate. Int J Oral-Med Sci 6, 14-18.10.5466/ijoms.6.14 ↗
13. 14. Ihara C, Takahashi H, Matsui R, Yamanaka T, Ueno T (2009) Bonding durability of custom-made mouthpiece for scuba diving after water storage under pressure. Dent Mater J 28, 487-492.10.4012/dmj.28.487 ↗
14. 15. Yokota K (2010) Adhesion of dental silicone rubber material to thermoplastic material for mouthguards. J Stomatol Soc Jpn 77, 46-52.
15. 16. Ng CC, Dumbrigue HB, Al-Bayat MI, Griggs JA, Wakefield CW (2006) Influence of remaining coronal tooth structure location the fracture resistance of restored endodontically treated anterior teeth. J Prosthet Dent 95, 290-296.10.1016/j.prosdent.2006.02.026 ↗
16. 17. Nissan J, Zukerman O, Rosenfelder S, Barnea E, Shifman A (2007) Effect of endodontic access type on the resistance to fracture of maxillary incisors. Quintessence Int 38, 364-367.
17. 18. Mihindukulasuriya S, Lim L.-T. (2012) Effects of liquid contaminants on heat seal strength of low-density polyethylene film. Pacag. Technol. Sci 25, 271-284.
18. 19. Takeda T, Ishigami K, Kawamura S, Nakajima K, Shimada A, Sumii T et al. (2006) Adhesive strength and its improvement referring to the laminated-type mouthguard. Dent Traumatol 22, 205-214.10.1111/j.1600-9657.2006.00427.x ↗
19. 20. Del Rossi, Leyte-Vidal M (2007) Fabricating a better mouthguard. Part I: factors influencing mouthguard thinning. Dent Traumatol 23, 149-154.10.1111/j.1600-9657.2006.00436.x ↗
20. 21. Waked EJ, Caputo AA (2005) Thickness and stiffness characteristics of custom-made mouthguard materials. Quintessence Int 36, 462-466.