journal article·2021Open access

The use of micro-computed tomography to determine the accuracy of electronic working length with two apex locators

Hisashi Suguro, Anna Nishihara, Takahito Tamura, Takeshi Nakamura, Yurika Toyama, Osamu Takeichi

Journal of Oral Science· Volume 63· Issue 2

Abstract

PURPOSE: This study evaluated the precision of electronic working length by microcomputed tomography using two electronic apex locators (EALs). METHODS: Twenty single-rooted permanent teeth without caries or restorations were selected as the subject teeth. The positions of the minor apical constriction (AC) and major apical foramen (AF) were measured by electronic root canal length, and microcomputed tomography was performed with the file inserted and fixed in the root canal. All teeth were measured individually and independently by two operators. The Mann-Whitney U-test was used to statistically test the AC and AF values using two EALs; P < 0.05 was defined as statistically significant. RESULTS: This was 65.0% within 1.5 mm in the case of two EALs on AC. This was more than 90.0% within 1.0 mm in the case of two EALs on AF. Comparison of the differences between the respective AC and AF of the measurements obtained using the two EALs revealed no significant difference. CONCLUSION: The two EALs are devices that can greatly improve the accuracy of WL control.
Source: openalex_inverted_index · Quality: baseline

Research context

OpenAlex topics: Endodontics and Root Canal Treatments · Dental Radiography and Imaging · Dental Erosion and Treatment

SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.

Affiliations

Department of Endodontics, Nihon University School of Dentistry

Division of Advanced Dental Treatment, Dental Research Center, Nihon University School of Dentistry

Division of Oral Structural and Functional Biology, Nihon University Graduate School of Dentistry

Division of Applied Oral Sciences, Nihon University Graduate School of Dentistry

References (27)

Show source-provided references
1. 1. Gordon MPJ, Chandler NP (2004) Electronic apex locators. IntEndod J 37, 425-437.
2. 2. Nekoofar MH, Ghandi MM, Hayes SJ, Dummer PM (2006) The fundamental operating principles of electronic root canal length measurement devices. Int Endod J 39, 595-609.10.1111/j.1365-2591.2006.01131.x ↗
3. 3. Brunton P, Abdeen D, MacFarlane T (2002) The effect of an apex locator on exposure to radiation during endodontic therapy. J Endod 28, 524-526.10.1097/00004770-200207000-00009 ↗
4. 4. Vertucci F (2005) Root canal morphology and its relationship to endodontic procedures. Endodontic Topics 10, 3-29.10.1111/j.1601-1546.2005.00129.x ↗
5. 5. Kuttler Y (1955) Microscopic investigation of root apexes. J Am Dent Assoc 50, 544-552.10.14219/jada.archive.1955.0099 ↗
6. 6. Green D (1960) A stereomicroscopic study of 700 root apices of maxillary and mandibular posterior teeth. Oral Surg Oral Med Oral Pathol 13, 728-733.10.1016/0030-4220(60)90373-X ↗
7. 7. Stein TJ, Corcoran JF (1992) Radiographic “working length” revisited Oral Surg Oral Med Oral Pathol 74, 796-800.10.1016/0030-4220(92)90412-J ↗
8. 8. Pineda F, Kuttler Y (1972) Mesiodistal and buccolingual roentgenographic investigation of 7,275 root canals. Oral Surg Oral Med Oral Pathol 33, 101-110.10.1016/0030-4220(72)90214-9 ↗
9. 9. McDonald NJ (1992) The electronic determination of working length. Dent Clin North Am 36, 293-307.10.1016/S0011-8532(22)02497-1 ↗
10. 10. Pratten D, McDonald NJ (1996) Comparison of radiographic and electronic working lengths, J Endod 22, 173-176.10.1016/S0099-2399(96)80095-1 ↗
11. 11. Fouad AF, Reid LC (2000) Effect of using electronic apex locators on selected endodontic treatment parameters. J Endod 26, 364-367.10.1097/00004770-200006000-00013 ↗
12. 12. ElAyouti A, Weiger R, Lost C (2001) Frequency of overinstrumentation with an acceptable radiographic working length. J Endod 27, 49-52.10.1097/00004770-200101000-00018 ↗
13. 13. Fouad AF, Rivera EM, Krell KV (1993) Accuracy of the Endex with variations in canal irrigants and foramen size. J Endod 19, 63-67.10.1016/S0099-2399(06)81196-9 ↗
14. 14. Ounsi HF, Haddad G (1998) In vitro evaluation of the reliability of the Endex electronic apex locator. J Endod 24, 120-121.10.1016/S0099-2399(98)80090-3 ↗
15. 15. Hoer D, Attin T (2004) The accuracy of electronic working length determination. Int Endod J 37, 125-131.10.1111/j.0143-2885.2004.00764.x ↗
16. 16. Ejima K, Omasa S, Motoyoshi M, Arai Y, Kai Y, Amemiya T et al. (2012) Influence of metal artifacts on in vivo micro-CT for orthodontic mini-implants. J Oral Sci 54, 55-59.10.2334/josnusd.54.55 ↗
17. 17. Udagawa A, Sato S, Hasuike A, Kishida M, Arai Y, Ito K (2013) Micro-CT observation of angiogenesis in bone regeneration. Clin Oral Implan Res 24, 787-792.10.1111/j.1600-0501.2012.02458.x ↗
18. 18. Suguro H, Takeichi O, Hayashi M, Okamura T, Hira A, Hirano Y et al. (2018) Microcomputed tomographic evaluation of techniques for warm gutta-percha obturation. J Oral Sci 60, 165-169.10.2334/josnusd.17-0092 ↗
19. 19. Meder-Cowherd L, Williamson AE, Johnson WT, Vasilescu D, Walton R, Qian F (2011) Apical morphology of the palatal roots of maxillary molars by using micro-computed tomography. J Endod 37, 1162-1165.10.1016/j.joen.2011.05.012 ↗
20. 20. ElAyouti A, Hülber-J M, Judenhofer MS, Connert T, Mannheim JG, Löst C et al. (2014) Apical constriction: location and dimensions in molars-a micro-computed tomography study. J Endod 40, 1095-1099.10.1016/j.joen.2013.12.002 ↗
21. 21. Ricucci D, Langeland K (1998) Apical limit of root canal instrumentation and obturation, part 2. A histological study. Int Endod J 31, 394-409.10.1046/j.1365-2591.1998.00183.x ↗
22. 22. Villas-Bôas MH, Bernardineli N, Cavenago BC, Marciano M, Del Carpio-Perochena A, de Moraes IG et al. (2011) Micro-computed tomography study of the internal anatomy of mesial root canals of mandibular molars. J Endod 37, 1682-1686.10.1016/j.joen.2011.08.001 ↗
23. 23. Sjogren U, Hagglund B, Sundqvist G, Wing K (1990) Factors affecting the long-term results of endodontic treatment. J Endod 16, 498-504.10.1016/S0099-2399(07)80180-4 ↗
24. 24. Chugal NM, Clive JM, Spångberg LS (2003) Endodontic infection: some biologic and treatment factors associated with outcome. Oral Surg Oral Med Oral Pathol Oral Radiol Endod 96, 81-90.10.1016/S1079-2104(02)91703-8 ↗
25. 25. Pagavino G, Pace R, Baccetti T (1998) A SEM study of in vivo accuracy of the Root ZX electronic apex locator. J Endod 24, 438-441.10.1016/S0099-2399(98)80029-0 ↗
26. 26. Tselnik M, Baumgartner JC, Marshall JG (2005) An evaluation of root ZX and elements diagnostic apex locators. J Endod 31, 507-509.10.1097/01.don.0000152295.05827.80 ↗
27. 27. Guise GM, Goodell GG, Imamura GM (2011) In vitro comparison of three electronic apex locators. J Endod 36, 279-281.10.1016/j.joen.2009.09.016 ↗