Clinical application of an intraoral scanner and CAD/CAM system for a Kennedy class I partially edentulous patient
Source abstract
Abstract
Traditionally, removable partial dentures (RPDs) have been made by using an elastic impression material and casting from a framework wax pattern on a refractory cast. In this short communication, the procedures for digitally fabricating removable partial dentures using an intraoral scanner (IOS) and additive manufacturing system (AM) are described. The adaptation accuracy of the RPD using IOS and AM techniques was evaluated subjectively as good or satisfactory.
Source: openalex_inverted_index · Quality: baseline
Research context
OpenAlex topics: Dental materials and restorations · Dental Research and COVID-19 · Dental Implant Techniques and Outcomes
SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.
Affiliations
Department of Removable Prosthodontics, Tsurumi University School of Dental Medicine
Technician Training Institute, Tsurumi University School of Dental Medicine
References (8)
Show source-provided references
1. 1. Ohkubo C, Sato Y, Nishiyama Y, Suzuki Y (2017) Titanium removable denture based on a one-metal rehabilitation concept. Dent Mater J 36, 517-523.10.4012/dmj.2017-137 ↗
2. 2. Suzuki Y, Shimizu S, Waki T, Shimpo H, Ohkubo C (2021) Laboratory efficiency of additive manufacturing for removable denture frameworks: a literature-based review. Dent Mater J 31, 265-271.10.4012/dmj.2020-206 ↗
3. 3. Kihara H, Hatakeyama W, Komine F, Takafuji K, Takahashi T, Yokota J et al. (2020) Accuracy and practicality of intraoral scanner in dentistry: a literature review. J Prosthodont Res 64, 109-113.10.1016/j.jpor.2019.07.010 ↗
4. 4. Irving T,Walter R,Abigail K, Dalton W (2019) Evaluation of removable partial denture frameworks fabricated using 3 different techniques. J Prosthet Dent 122, 390-395.10.1016/j.prosdent.2018.10.013 ↗
5. 5. Mansour M, Sanchez E, Machado C (2016) The use of digital impressions to fabricate tooth-supported partial removable dental prostheses: a clinical report. J Prosthodont 25, 495-497.10.1111/jopr.12346 ↗
6. 6. Williams RJ, Bibb R, Eggbeer D, Collis J (2006) Use of CAD/CAM technology to fabricate a removable partial denture framework. J Prosthet Dent 96, 96-99.10.1016/j.prosdent.2006.05.029 ↗
7. 7. Shimpo H (2008) Effect of arm design and chemical polishing on retentive force of cast titanium alloy clasps. J Prosthodont 17, 300-307.10.1111/j.1532-849X.2007.00289.x ↗
8. 8. Diwan R, Talic Y, Omar N, Sadiq W (1997) The effect of storage time of removable partial denture wax pattern on the accuracy of fit of the cast framework. J Prosthet Dent 77, 375-381.10.1016/S0022-3913(97)70162-8 ↗