Effect of food-simulating solvents on flexural properties of bulk-fill resin composites
Source abstract
Abstract
Purpose This study evaluated the flexural strength of bulk-fills after immersion in food-simulating solvents. Methods Four overlapping segments along both sides of bar-shaped specimens (25 × 2 × 2 mm) made from bulk-fill composite were irradiated with an Elipar LED light-curing (1,200 mW/cm2 for 20 s) device. The specimens were then divided into four groups (n = 20), according to storage media-namely, distilled water, 99% ethanol, heptane, and methyl ethyl ketone-at 37oC for 4 weeks. Flexural testing was done with a universal testing machine at a crosshead speed of 1 mm/min. Results Data were analyzed with the two-way and one-way ANOVA and post-hoc Tukey (HSD) tests (P < 0.05), along with the Weibull statistic. Flexural properties significantly differed in relation to the bulk-fill and solvent used. The flexural properties of bulk-fills decreased in solvents. SonicFill in distilled water had the highest values for flexural properties (σf = 165.77 MPa; Ef = 10.3 GPa), followed by the values for SonicFill in ethanol and those for X-tra base and everX Posterior in water. Venus Bulk Fill in methyl ethyl ketone yielded the lowest values (σf = 74.11 MPa; Ef = 3.06 GPa). Conclusion The flexural properties of bulk-fills are affected by the food-simulating solvent used and by the filler content, type, and resin component.
Source: europepmc · Quality: candidate unverified · Source record ↗
Research context
OpenAlex topics: Dental materials and restorations · Additive Manufacturing and 3D Printing Technologies · Photopolymerization techniques and applications
SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.
Affiliations
Dental Restorative Biomaterials, Biomechanics & Adhesion-Research Group in Operative and Esthetic Dentistry Division, Restorative Dentistry Department, Faculty of Dentistry, King Abdulaziz University
References (40)
Show source-provided references
1. 1. Czasch P, Ilie N (2013) In vitro comparison of mechanical properties and degree of cure of bulk fill composites. Clin Oral Investig 17, 227-235.10.1007/s00784-012-0702-8 ↗
2. 2. Bucuta S, Ilie N (2014) Light transmittance and micro-mechanical properties of bulk fill vs. conventional resin based composites. Clin Oral Investig 18, 1991-2000.10.1007/s00784-013-1177-y ↗
3. 3. Ilie N, Bucuta S, Draenert M (2013) Bulk-fill resin-based composites: an in vitro assessment of their mechanical performance. Oper Dent 38, 618-625.10.2341/12-395-L ↗
4. 4. Cidreira Boaro LC, Pereira Lopes D, de Souza ASC, Lie Nakano E, Ayala Perez MD, Pfeifer CS et al. (2019) Clinical performance and chemical-physical properties of bulk fill composites resin -a systematic review and meta-analysis. Dent Mater 35, e249-e264.10.1016/j.dental.2019.07.007 ↗
5. 5. Goracci C, Cadenaro M, Fontanive L, Giangrosso G, Juloski J, Vichi A et al. (2014) Polymerization efficiency and flexural strength of low-stress restorative composites. Dent Mater 30, 688-694.10.1016/j.dental.2014.03.006 ↗
6. 6. McKinney JE, Wu W (1985) Chemical softening and wear of dental composites. J Dent Res 64, 1326-1331.10.1177/00220345850640111601 ↗
7. 7. Lagocka R, Mazurek-Mochol M, Jakubowska K, Bendyk-Szeffer M, Chlubek D, Buczkowska-Radlinska J (2018) Analysis of base monomer elution from 3 flowable bulk-fill composite resins using high performance liquid chromatography (HPLC). Med Sci Monit 24, 4679-4690.10.12659/MSM.907390 ↗
8. 8. Kwon OH, Kim DH, Park SH (2010) The influence of elastic modulus of base material on the marginal adaptation of direct composite restoration. Oper Dent 35, 441-447.10.2341/09-372-L ↗
9. 9. Marghalani HY, Watts DC (2013) Viscoelastic stability of resin-composites aged in food-simulating solvents. Dent Mater 29, 963-970.10.1016/j.dental.2013.07.009 ↗
10. 10. Mohammadi E, Pishevar L, Mirzakouchaki Boroujeni P (2017) Effect of food simulating liquids on the flexural strength of a methacrylate and silorane-based composite. PLoS One 12, e0188829.10.1371/journal.pone.0188829 ↗
11. 11. International Organization for Standardization (2009) Dentistry—Polymer based restorative materials. ISO 4049:2009, Geneve.
12. 12. McCabe JF, Carrick TE (1986) A statistical approach to the mechanical testing of dental materials. Dent Mater 2, 139-142.10.1016/S0109-5641(86)80021-5 ↗
13. 13. Øysaed H, Ruyter IE (1986) Composites for use in posterior teeth: mechanical properties tested under dry and wet conditions. J Biomed Mater Res 20, 261-271.10.1002/jbm.820200214 ↗
14. 15. Benetti AR, Havndrup-Pedersen C, Honoré D, Pedersen MK, Pallesen U (2015) Bulk-fill resin composites: polymerization contraction, depth of cure, and gap formation. Oper Dent 40, 190-200.10.2341/13-324-L ↗
15. 16. Ilie N, Hickel R (2009) Investigations on mechanical behaviour of dental composites. Clin Oral Investig 13, 427-438.10.1007/s00784-009-0258-4 ↗
16. 17. Leprince JG, Palin WM, Vanacker J, Sabbagh J, Devaux J, Leloup G (2014) Physico-mechanical characteristics of commercially available bulk-fill composites. J Dent 42, 993-1000.10.1016/j.jdent.2014.05.009 ↗
17. 18. Asmussen E, Peutzfeldt A (1998) Influence of UEDMA BisGMA and TEGDMA on selected mechanical properties of experimental resin composites. Dent Mater 14, 51-56.10.1016/S0109-5641(98)00009-8 ↗
18. 19. Garoushi S, Lassila LV, Vallittu PK (2012) The effect of span length of flexural testing on properties of short fiber reinforced composite. J Mater Sci Mater Med 23, 325-328.10.1007/s10856-011-4480-7 ↗
19. 20. Garoushi S, Vallittu PK, Lassila LV (2007) Short glass fiber reinforced restorative composite resin with semi-inter penetrating polymer network matrix. Dent Mater 23, 1356-1362.10.1016/j.dental.2006.11.017 ↗
20. 21. Yanagida H, Tanoue N, Minesaki Y, Kamasaki Y, Fujiwara T, Minami H (2017) Effects of polymerization method on flexural and shear bond strengths of a fiber-reinforced composite resin. J Oral Sci 59, 13-21.10.2334/josnusd.16-0117 ↗
21. 22. Kim KH, Ong JL, Okuno O (2002) The effect of filler loading and morphology on the mechanical properties of contemporary composites. J Prosthet Dent 87, 642-649.10.1067/mpr.2002.125179 ↗
22. 23. Garoushi S, Sailynoja E, Vallittu PK, Lassila L (2013) Physical properties and depth of cure of a new short fiber reinforced composite. Dent Mater 29, 835-841.10.1016/j.dental.2013.04.016 ↗
23. 24. Sideridou ID, Karabela MM, Bikiaris DN (2007) Aging studies of light cured dimethacrylate-based dental resins and a resin composite in water or ethanol/water. Dent Mater 23, 1142-1149.10.1016/j.dental.2006.06.049 ↗
24. 25. Papadogiannis D, Tolidis K, Lakes R, Papadogiannis Y (2011) Viscoelastic properties of low-shrinking composite resins compared to packable composite resins. Dent Mater J 30, 350-357.10.4012/dmj.2010-181 ↗
25. 26. Vouvoudi EC, Sideridou ID (2013) Effect of food/oral-simulating liquids on dynamic mechanical thermal properties of dental nanohybrid light-cured resin composites. Dent Mater 29, 842-850.10.1016/j.dental.2013.04.013 ↗
26. 27. Moszner N, Fischer UK, Ganster B, Liska R, Rheinberger V (2008) Benzoyl germanium derivatives as novel visible light photoinitiators for dental materials. Dent Mater 24, 901-907.10.1016/j.dental.2007.11.004 ↗
27. 28. Fronza BM, Ayres A, Pacheco RR, Rueggeberg FA, Dias C, Giannini M (2017) Characterization of inorganic filler content, mechanical properties, and light transmission of bulk-fill resin composites. Oper Dent 42, 445-455.10.2341/16-024-L ↗
28. 29. Tauböck TT, Feilzer AJ, Buchalla W, Kleverlaan CJ, Krejci I, Attin T (2014) Effect of modulated photo-activation on polymerization shrinkage behavior of dental restorative resin composites. Eur J Oral Sci 122, 293-302.10.1111/eos.12139 ↗
29. 30. Sideridou I, Tserki V, Papanastasiou G (2002) Effect of chemical structure on degree of conversion in light-cured dimethacrylate-based dental resins. Biomaterials 23, 1819-1829.10.1016/S0142-9612(01)00308-8 ↗
30. 31. Ferracane JL, Berge HX, Condon JR (1998) In vitro aging of dental composites in water--effect of degree of conversion, filler volume, and filler/matrix coupling. J Biomed Mater Res 42, 465-472.10.1002/(SICI)1097-4636(19981205)42:3<465::AID-JBM17>3.0.CO;2-F ↗
31. 32. Yap AU, Chew CL, Ong LF, Teoh SH (2002) Environmental damage and occlusal contact area wear of composite restoratives. J Oral Rehabil 29, 87-97.10.1046/j.1365-2842.2002.00797.x ↗
32. 33. Guo G, Fan Y, Zhang JF, Hagan JL, Xu X (2012) Novel dental composites reinforced with zirconia-silica ceramic nanofibers. Dent Mater 28, 360-368.10.1016/j.dental.2011.11.006 ↗
33. 34. Calais JG, Söderholm KJ (1988) Influence of filler type and water exposure on flexural strength of experimental composite resins. J Dent Res 67, 836-840.10.1177/00220345880670050801 ↗
34. 35. Mair LH, Krishnan VK (1999) Three body wear studies of five dental composites preconditioned in food simulating media. Bio-med Mater Eng 9, 145-149.
35. 36. Schneider LF, Moraes RR, Cavalcante LM, Sinhoreti MA, Correr-Sobrinho L, Consani S (2008) Cross-link density evaluation through softening tests: effect of ethanol concentration. Dent Mater 24, 199-203.10.1016/j.dental.2007.03.010 ↗
36. 37. Lee SY, Greener EH, Menis DL (1995) Detection of leached moieties from dental composites in fluids simulating food and saliva. Dent Mater 11, 348-353.10.1016/0109-5641(95)80033-6 ↗
37. 38. Sideridou ID, Karabela MM (2011) Sorption of water, ethanol or ethanol/water solutions by light-cured dental dimethacrylate resins. Dent Mater 27, 1003-1010.10.1016/j.dental.2011.06.007 ↗
38. 39. Par M, Gamulin O, Marovic D, Klaric E, Tarle Z (2015) Raman spectroscopic assessment of degree of conversion of bulk-fill resin composites--changes at 24 hours post cure. Oper Dent 40, E92-E101.10.2341/14-091-L ↗
39. 40. Mante F, Saleh N, Mante M (1993) Softening patterns of post-cure heat-treated dental composites. Dent Mater 9, 325-331.10.1016/0109-5641(93)90051-Q ↗