journal article·2022Open access

Accuracy of a guided implant system with milled surgical templates

Jeanette K. Li-Rodríguez, Miguel Díaz-Durany, Marta Romeo-Rubio, María Paz Salido, Guillermo Pradíes

Journal of Oral Science· Volume 64· Issue 2

Abstract

PURPOSE: This in vitro study analyzed the accuracy of a computer-assisted design (CAD)/computer-assisted manufacturing (CAM) guided implant surgery system by comparing linear, angular, and coronal deviations between the planned and final implant placement. METHODS: By using a fully guided surgery workflow, 32 dental implants were placed in 16 partially edentulous models. After virtual design of the restorations, radiological and CAD files were matched and implant positions were planned by using dedicated implant planning software (Galileo Implant version 1.9.2.). Templates were designed (Cerec Omnicam) and milled (Cerec MC XL) by using chairside workflow. Galileo Implant version 1.9.2. was used to evaluate accuracy. RESULTS: Mean horizontal and angular-coronal total deviation values were 0.2 mm (SD = 0.126) and 1.1º (SD = 0.834) respectively. Multivariate analysis of variance showed significant differences in horizontal and angular-coronal total deviation in the 32 implants (P = 0.0001). Multivariate analysis with one-factor interaction showed no statistical difference in implant position or implant type (P = 0.139) between eight maxilla models and eight jaw models. CONCLUSION: Horizontal and angular-coronal deviations of implants placed with chairside digital workflow were within the recommended safety margin for fully guided surgery.
Source: openalex_inverted_index · Quality: baseline

Research context

OpenAlex topics: Dental Implant Techniques and Outcomes · Dental Radiography and Imaging · Orthodontics and Dentofacial Orthopedics

SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.

Affiliations

Department of Conservative Dentistry and Buccofacial Prostheses, Complutense of Madrid University

Oral Surgery and Implantology, Rey Juan Carlos University

References (39)

Show source-provided references
1. 1. Jung RE, Zembic A, Pjetursson BE, Zwahlen M, Thoma DS (2012) Systematic review of the survival rate and the incidence of biological, technical, and aesthetic complications of single crowns on implants reported in longitudinal studies with a mean follow-up of 5 years. Clin Oral Implants Res 23, 2-21.10.1111/j.1600-0501.2012.02547.x ↗
2. 2. Naeini EN, Atashkadeh M, De Bruyn H, D´haese J (2020) Narrative review regarding the applicability, accuracy, and clinical outcome of flapless implant surgery with or without computer guidance. Clin Implant Dent Relat Res 22, 454-467.10.1111/cid.12901 ↗
3. 3. Jones A (2018) Accuracy of mucosa supported guided implant surgery. Clin Case Rep 6, 2131-2139.10.1002/ccr3.1809 ↗
4. 4. Tatakis DN, Chien HH, Parashis AO (2019) Guided implant surgery risks and their prevention. Periodontol 2000 81, 194-208.10.1111/prd.12292 ↗
5. 5. Lee DH, An SY, Hong MH, Jeon KB, Lee KB (2016) Accuracy of a direct drill-guiding system with minimal tolerance of surgical instruments used for implant surgery: a prospective clinical study. J Adv Prosthodont 8, 207-213.10.4047/jap.2016.8.3.207 ↗
6. 6. D´haese J, Ackhurst J, Wismeijer D, De Bruyn H, Tahmaseb A (2017) Current state of the art of computer-guided implant surgery. Periodontol 2000 73, 121-133.10.1111/prd.12175 ↗
7. 7. Tahmaseb A, Wu V, Wismeijer D, Coucke W, Evans C (2018) The accuracy of static computer-aided implant surgery: a systematic review and meta-analysis. Clin Oral Implants Res 29, 416-435.10.1111/clr.13346 ↗
8. 8. Zhou W, Liu Z, Song L, Kuo CL, Shafer D (2018) Clinical factors affecting the accuracy of guided implant surgery – a systematic review and meta-analysis. J Evid Base Dent Pract 18, 28-40.10.1016/j.jebdp.2017.07.007 ↗
9. 9. Unsal GS, Turkyilmaz l, Lakhia S (2020) Advantages and limitations of implant surgery with CAD/CAM surgical guides: a literature review. J Clin Expert Dent 12, e409-e417.10.4317/jced.55871 ↗
10. 10. Lin CC, Wu CZ, Huang MS, Huang CF, Cheng HC, Wang DP (2020) Fully digital workflow for planning static guided implant surgery: a prospective accuracy study. J Clin Med 9, 980.10.3390/jcm9040980 ↗
11. 11. Jacobs R, Salmon B, Codari M, Hassan B, Bornstein MM (2018) Cone beam computed tomography in implant dentistry: recommendations for clinical use. BMC Oral Health 18, 88.10.1186/s12903-018-0523-5 ↗
12. 12. Flügge T, Dersken W, Te Poel J, Hassan B, Nelson K, Wismeijer D (2017) Registration of cone beam computed tomography data and intraoral surface scans – a prerequisite for guided implant surgery with CAD/CAM drilling guides. Clin Oral Implants Res 28, 1113-1118.10.1111/clr.12925 ↗
13. 13. Schubert O, Schweiger J, Stimmelmayr M, Nold E, Güth JF (2019) Digital implant planning and guided implant surgery-workflow and reliability. Br Dent J 226, 101-108.10.1038/sj.bdj.2019.44 ↗
14. 14. Di Giacomo GA, Cury PR, Soares de Araujo NS, Sendyk WR, Sendyk CL (2005) Clinical application of stereolithographic surgical guides for implant placement: preliminary results. J Periodontol 76, 503-507.10.1902/jop.2005.76.4.503 ↗
15. 15. Ozan O, Turkyilmaz I, Ersoy AE, Mc Glumphy EA, Rosenstiel SF (2013) Clinical accuracy of 3 different types of computed tomography-derived stereolithographic surgical guides in implant placement. J Oral Maxillofac Surg 67, 394-401.10.1016/j.joms.2008.09.033 ↗
16. 16. Gargallo-Albiol J, Barootchi S, Marqués-Guasch J, Wang HL (2020) Fully guided versus half-guided and freehand implant placement: systematic review and meta-analysis. Int J Oral Maxillofac Implants 35, 1159-1169.10.11607/jomi.7942 ↗
17. 17. Berli C, Thieringer FM, Sharma N, Müller JA, Dedem P, Fischer J et al. (2020) Comparing the mechanical properties of pressed, milled and 3D printed resins for occlusal devices. J Prosthet Dent 124, 780-786.10.1016/j.prosdent.2019.10.024 ↗
18. 18. Jeong YG, Lee WS, Lee KB (2018) Accuracy evaluation of dental models manufactured by CAD/CAM milling method and 3D printing method. J Adv Prosthodont 10, 245-251.10.4047/jap.2018.10.3.245 ↗
19. 19. Koop R, Vercruyssen M, Vermeulen K, Quirynen M (2013) Tolerance within the sleeve inserts of different surgical guides for guided implant surgery. Clin Oral Implants Res 24, 630-634.10.1111/j.1600-0501.2012.02436.x ↗
20. 20. Laederach V, Mukaddam K, Payer M, Filippi A, Kühl S (2017) Deviations of different systems for guided implant surgery. Clin Oral Implant Res 28,1147-1151.10.1111/clr.12930 ↗
21. 21. Schulze R, Heil U, Gross D, Bruellmann DD, Dranischnikow E, Schwanecke U et al. (2011) Artefacts in CBCT: a review. Dentomaxillofac Radiol 40, 265-273.10.1259/dmfr/30642039 ↗
22. 22. Bornstein MM, Horner K, Jacobs R (2017) Use of cone beam computed tomography in implant dentistry: current concepts, indications and limitations for clinical practice and research. Periodontol 2000 73, 51-72.10.1111/prd.12161 ↗
23. 23. Ender A, Zimmermann M, Mehl A (2019) Accuracy of complete-and partial-arch impressions of actual intraoral scanning systems in vitro. Int J Comput Dent 22, 11-19.
24. 24. Choi YD, Mai HN, Mai HY, Ha JH, Li LJ, Lee DH (2020) The effects of distribution of image matched fiducial markers on accuracy of computer-guided implant surgery. J Prosthodont 29, 409-414.10.1111/jopr.13171 ↗
25. 25. Motel C, Kirchner E, Adler W, Wichmann M, Matta RE (2020) Impact of different scan bodies and scan strategies on the accuracy of digital implant impressions. Assessed with an intraoral scanner: an in vitro study. J Prosthodont 29, 309-314.10.1111/jopr.13131 ↗
26. 26. Di Giacomo GA, Cury PR, Soares de Araujo N, Sendyk WR, Sendyk CL (2005) Clinical application of stereolithographic surgical guides for implant placement: preliminary results. J Periodontol 76, 503-507.10.1902/jop.2005.76.4.503 ↗
27. 27. Ozan O, Turkyilmaz I, Ersoy AE, McGumphy EA, Rosentiel SF (2009) Clinical accuracy of 3 different types of computed tomography-derived stereolithographic surgical guides in implant placement. J Oral Maxillofac Surg 67, 394-401.10.1016/j.joms.2008.09.033 ↗
28. 28. Widmann G, Zangerl A, Keiler M, Stoffner R, Bale R, Puelacher W (2010) Flapless implant surgery in the edentulous jaw based on three fixed intraoral reference points and image-guided surgical templates: accuracy in human cadavers. Clin Oral Implant Res 21, 835-841.10.1111/j.1600-0501.2009.01884.x ↗
29. 29. Arisan V, karabuda ZC, Ozdemir T (2010) Accuracy of two stereolithographic guide systems for computer-aided implant placement: a computed tomography-based clinical comparative study. J Periodontol 81, 43-51.10.1902/jop.2009.090348 ↗
30. 30. Soares MM, Harari ND, Cardoso ES, Manso MC, Conz MB, Vidigal GM (2012) An in vitro model to evaluate the accuracy of guided surgery systems. Int J Oral Maxillofac Implants 27, 824-831.
31. 31. Bover-Ramos F, Viña-Almunia J, Cervera-Ballester J, Peñarrocha-Diago M, Garcia-Mira B (2018) Accuracy of implant placement with computer-guided surgery: a systematic review and meta-analysis comparing cadaver, clinical, and in vitro studies. Int J Oral Maxillofac Implants 33, 101-115.10.11607/jomi.5556 ↗
32. 32. Vasak C, Watzak G, Gahleitner A, Strbac G, Schemper M, Zechner W (2011) Computed tomography-based evaluation of template (Nobel Guide) guided implant position: a prospective radiological study. Clin Oral Implants Res 22, 1157-1163.10.1111/j.1600-0501.2010.02070.x ↗
33. 33. Vieira DM, Sotto-Maior BS, Barros CA, Reis ES, Francischone CE (2013) Clinical accuracy of flapless computer-guided surgery for implant placement in edentulous arches. Int J Oral Maxillofac Implants 28, 1347-1351.10.11607/jomi.3156 ↗
34. 34. Cassetta M, Di Mambro A, Giansanti M, Stefanelli LV, Cavallini C (2013) The intrinsic error of a stereolithographic surgical template in implant guided surgery. Int J Oral Maxillofac Surg 42, 264-275.10.1016/j.ijom.2012.06.010 ↗
35. 35. Cristache CM, Gurbanescu S (2017) Accuracy evaluation of a stereolitographic surgical template for dental implant insertion using 3D superimposition protocol. Int J Dent 2017, 2-9.10.1155/2017/4292081 ↗
36. 36. El Kholy K, Janner SFM, Schimmel M, Buser D (2019) The influence of guided sleeve height, drilling distance, and drilling key length on the accuracy of static computer-assisted implant surgery. Clin Implant Dent Relat Res 21, 101-107.10.1111/cid.12705 ↗
37. 37. Cushen SE, Turkyilmaz l (2013) Impact of operator experience on the accuracy of implant placement with stereolithographic surgical templates: an in vitro study. J Prosthet Dent 109, 248-254.10.1016/S0022-3913(13)60053-0 ↗
38. 38. Raico Gallardo YN, Rodrigues Teixeirada da Silva-Olivio I, Mukai E, Morimoto S, Sesma N, Cordaro L (2017) Accuracy comparison of guided surgery for dental implants according to the tissue of support: a systematic review and meta-analysis. Clin Oral Implants Res 28, 602-612.10.1111/clr.12841 ↗
39. 39. Van de Wiele G, Teughels W, Vercruyssen M, Coucke W, Temmerman A, Quirynen M (2015) The accuracy of guided surgery via mucosa-supported stereolithographic surgical templates in the hands of surgeons with little experience. Clin Oral Implants Res 26,1489-1494.10.1111/clr.12494 ↗