journal article·2014Open access

Root proximity and stability of orthodontic anchor screws

Toru Shigeeda

Journal of Oral Science· Volume 56· Issue 1

Abstract

This study aimed to investigate a causal relationship between the stability of orthodontic anchor screws (screws) and the degree of their proximity to the root (root proximity) using mobility test device (Periotest) and cone-beam computed tomography (CBCT). In total, 165 (diameter 1.6 mm; length 8 mm) screws in 58 patients (average age, 24.4 ± 8.5 years) were evaluated. After screw placement, CBCT was used for diagnostic imaging of the area around the site. Root proximity was evaluated and categorized into three groups: A, no contact; B, single contact; and C, multi-contact. The Periotest value was used to assess screw stability. The screw failure rate according to root proximity significantly differed between categories A and C. In addition, failure rate significantly differed between mandibular screws with and without root contact. Periotest values in categories A and C were significantly higher in the mandible than in the maxilla. Mandibular screws had greater mobility than maxillar screws, even when the screw avoided root contact. The lower stability of mandibular screws with root contact might be related to their greater mobility.
Source: openalex_inverted_index · Quality: baseline

Research context

OpenAlex topics: Orthodontics and Dentofacial Orthopedics · Dental Radiography and Imaging · Facial Trauma and Fracture Management

SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.

References (28)

Show source-provided references
1. 1. Kanomi R (1997) Mini-implant for orthodontic anchorage. J Clin Orthod 31, 763-767.
2. 2. Freudenthaler JW, Bantleon HP, Haas R (2001) Bicortical titanium screws for critical orthodontic anchorage in the mandible: a preliminary report on clinical applications. Clin Oral Implants Res 12, 358-363.10.1034/j.1600-0501.2001.012004358.x ↗
3. 3. Lee JS, Park HS, Kyung HM (2001) Micro-implant anchorage for lingual treatment of a skeletal Class II malocclusion. J Clin Orthod 35, 643-647.
4. 4. Bae SM, Park HS, Kyung HM, Kwon OW, Sung JH (2002) Clinical application of micro-implant anchorage. J Clin Orthod 36, 298-302.
5. 5. Park HS, Kyung HM, Sung JH (2002) A simple method of molar uprighting with micro-implant anchorage. J Clin Orthod 36, 592-596.
6. 6. Herman RJ, Currier GF, Miyake A (2006) Mini-implant anchorage for maxillary canine retraction: a pilot study. Am J Orthod Dentofacial Orthop 130, 228-235.10.1016/j.ajodo.2006.02.029 ↗
7. 7. Kim TW, Kim H, Lee SJ (2006) Correction of deep overbite and gummy smile by using a mini-implant with a segmented wire in a growing Class II division 2 patient. Am J Orthod Dentofacial Orthop 130, 676-685.10.1016/j.ajodo.2005.07.013 ↗
8. 8. Motoyoshi M (2011) Clinical indices for orthodontic mini-implants. J Oral Sci 53, 407-412.10.2334/josnusd.53.407 ↗
9. 9. Miyawaki S, Koyama I, Inoue M, Mishima K, Sugawara T, Takano-Yamamoto T (2003) Factors associated with the stability of titanium screws placed in the posterior region for orthodontic anchorage. Am J Orthod Dentofacial Orthop 124, 373-378.10.1016/S0889-5406(03)00565-1 ↗
10. 10. Motoyoshi M, Yoshida T, Ono A, Shimizu N (2007) Effect of cortical bone thickness and implant placement torque on stability of orthodontic mini-implants. Int J Oral Maxillofac Implants 22, 779-784.
11. 11. Kuroda S, Yamada K, Deguchi T, Hashimoto T, Kyung HM, Takano-Yamamoto T (2007) Root proximity is a major factor for screw failure in orthodontic anchorage. Am J Orthod Dentofacial Orthop 131, S68-73.10.1016/j.ajodo.2006.06.017 ↗
12. 12. Liou EJ, Pai BC, Lin JC (2004) Do miniscrews remain stationary under orthodontic forces? Am J Orthod Dentofacial Orthop 126, 42-47.10.1016/j.ajodo.2003.06.018 ↗
13. 13. Estelita CB, Janson G, Chiqueto K, Freitas MR, Henriques JFC, Pinzan A (2006) A three-dimensional radiographic-surgical guide for mini-implant placement. J Clin Orthod 40, 548-554.
14. 14. Choi HJ, Kim TW, Kim HW (2007) A precise wire guide for positioning interradicular miniscrews. J Clin Orthod 41, 258-261.
15. 15. Kim SH, Choi YS, Hwang EH, Chung KR, Kook YA, Nelson G (2007) Surgical positioning of orthodontic mini-implants with guides fabricated on models replicated with cone-beam computed tomography. Am J Orthod Dentofacial Orthop 131, S82-89.10.1016/j.ajodo.2006.01.027 ↗
16. 16. Kim SH, Kang SM, Choi YS, Kook YA, Chung KR, Huang JC (2010) Cone-beam computed tomography evaluation of mini-implants after placement: is root proximity a major risk factor for failure? Am J Orthod Dentofacial Orthop 138, 264-276.10.1016/j.ajodo.2008.07.026 ↗
17. 17. Mah JK, Huang JC, Choo H (2010) Practical applications of cone-beam computed tomography in orthodontics. J Am Dent Assoc 141, Suppl 3, 7S-13S.10.14219/jada.archive.2010.0361 ↗
18. 18. Watanabe H, Deguchi T, Hasegawa M, Ito M, Kim S, Takano-Yamamoto T (2013) Orthodontic miniscrew failure rate and root proximity, insertion angle, bone contact length, and bone density. Orthod Craniofac Res 16, 44-55.10.1111/ocr.12003 ↗
19. 19. Uemura M, Motoyoshi M, Yano S, Sakaguchi M, Igarashi Y, Shimizu N (2012) Orthodontic mini-implant stability and the ratio of pilot hole implant diameter. Eur J Orthod 34, 52-56.10.1093/ejo/cjq157 ↗
20. 20. Inaba M (2009) Evaluation of primary stability of inclined orthodontic mini-implants. J Oral Sci 51, 347-353.10.2334/josnusd.51.347 ↗
21. 21. Motoyoshi M, Hirabayashi M, Uemura M, Shimizu N (2006) Recommended placement torque when tightening an orthodontic mini-implant. Clin Oral Implants Res 17, 109-114.10.1111/j.1600-0501.2005.01211.x ↗
22. 22. Park HS, Jeong SH, Kwon OW (2006) Factors affecting the clinical success of screw implants used as orthodontic anchorage. Am J Orthod Dentofacial Orthop 130, 18-25.10.1016/j.ajodo.2004.11.032 ↗
23. 23. Min KI, Kim SC, Kang KH, Cho JH, Lee EH, Chang NY et al. (2012) Root proximity and cortical bone thickness effects on the success rate of orthodontic micro-implants using cone beam computed tomography. Angle Orthod 82, 1014-1021.10.2319/091311-593.1 ↗
24. 24. Kim H, Kim TW (2011) Histologic evaluation of root-surface healing after root contact or approximation during placement of mini-implants. Am J Orthod Dentofacial Orthop 139, 752-760.10.1016/j.ajodo.2009.06.042 ↗
25. 25. Brisceno CE, Rossouw PE, Carrillo R, Spears R, Buschang PH (2009) Healing of the roots and surrounding structures after intentional damage with miniscrew implants. Am J Orthod Dentofacial Orthop 135, 292-301.10.1016/j.ajodo.2008.06.023 ↗
26. 26. Asscherickx K, Vannet BV, Wehrbein H, Sabzevar MM (2005) Root repair after injury from mini-screw. Clin Oral Implants Res 16, 575-578.10.1111/j.1600-0501.2005.01146.x ↗
27. 27. Chen YH, Chang HH, Chen YJ, Lee D, Chiang HH, Yao CCJ (2008) Root contact during insertion of miniscrews for orthodontic anchorage increases the failure rate: an animal study. Clin Oral Implants Res 19, 99-106.10.1111/j.1600-0501.2007.01418.x ↗
28. 28. Kadioglu O, Büyükyilmaz T, Zachrisson BU, Maino BG (2008) Contact damage to root surfaces of premolars touching miniscrews during orthodontic treatment. Am J Orthod Dentofacial Orthop 134, 353-360.10.1016/j.ajodo.2006.09.069 ↗