journal article·2010Open access

Comparison of the effect of Er, Cr-YSGG laser and ultrasonic retrograde root-end cavity preparation on the integrity of root apices

Saeed Rahimi, Hamid R. Yavari, Shahriar Shahi, Vahid Zand, Sahar Shakoui, Mohammad F. Reyhani, Ahmad Pirzadeh

Journal of Oral Science· Volume 52· Issue 1

Abstract

The aim of this study was to compare the effect of Waterlase laser and ultrasonic root end cavity preparation on the integrity of root end in extracted human teeth. The canals of 60 extracted maxillary central incisors were cleaned, shaped, obturated and 3 mm of the root end was resected and examined for the presence of any cracks. Class I root-end cavities were then prepared using an ultrasonic unit or Waterlase laser. In the ultrasonic group, KIS 2D tip and medium intensity and in the laser group, 600 mum laser tips and an output power setting of 4 W with 55% water and 65% air were used to prepare the cavity which was studied for the presence of any cracks or chippings. One crack was found in the ultrasonic group, while no cracks were observed in the laser group. There was no significant difference between the two groups (P > 0.05). As for the chipping effect, seven cases (23%) had chipping after cavity preparation in the ultrasonic group but no chipping was found in the specimens of the laser group and the difference was statistically significant (P < 0.05). According to the results of this in vitro study, laser preserves the integrity of root-end cavities better than ultrasonic devices from the standpoint of producing chipping.
Source: openalex_inverted_index · Quality: baseline

Research context

OpenAlex topics: Endodontics and Root Canal Treatments · Dental materials and restorations · Laser Applications in Dentistry and Medicine

SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.

References (21)

Show source-provided references
1. 1. Carr GB (1997) Ultrasonic root-end preparation. Dent Clin North Am 41, 541-554.10.1016/S0011-8532(22)00067-2 ↗
2. 2. Saunders WP, Saunders EM, Gutmann JL (1994) Ultrasonic root-end preparation, Part 2. Microleakage of EBA root-end fillings. Int Endod J 27, 325-329.10.1111/j.1365-2591.1994.tb00277.x ↗
3. 3. Abedi HR, Van Mierlo BL, Wilder-Smith P, Torabinejad M (1995) Effects of ultrasonic root-end cavity preparation on the root apex. Oral Surg Oral Med Oral Pathol Oral Radiol Endod 80, 207-213.10.1016/S1079-2104(05)80204-5 ↗
4. 4. Waplington M, Lumley PJ, Walmsley AD (1997) Incidence of root face alteration after ultrasonic retrograde cavity preparation. Oral Surg Oral Med Oral Pathol Oral Radiol Endod 83, 387-392.10.1016/S1079-2104(97)90247-X ↗
5. 5. Layton CA, Marshall JG, Morgan LA, Baumgartner JC (1996) Evaluation of cracks associated with ultrasonic root-end preparation. J Endod 22, 157-160.10.1016/S0099-2399(96)80091-4 ↗
6. 6. Frank RJ, Antrim DD, Bakland LK (1996) Effect of retrograde cavity preparations on root apexes. Endod Dent Traumatol 12, 100-103.10.1111/j.1600-9657.1996.tb00105.x ↗
7. 7. De Bruyne MA, De Moor RJ (2005) SEM analysis of the integrity of resected root apices of cadaver and extracted teeth after ultrasonic root-end preparation at different intensities. Int Endod J 38, 310-319.10.1111/j.1365-2591.2005.00949.x ↗
8. 8. Van As G (2004) Erbium lasers in dentistry. Dent Clin North Am 48, 1017-1059.10.1016/j.cden.2004.06.001 ↗
9. 9. Karlovic Z, Pezelj-Ribaric S, Miletic I, Jukic S, Grgurevic J, Anic I (2005) Erbium:YAG laser versus ultrasonic in preparation of root-end cavities. J Endod 31, 821-823.10.1097/01.don.0000158234.33581.e9 ↗
10. 10. Wallace JA (2006) Effect of Waterlase laser retrograde root-end cavity preparation on the integrity of root apices of extracted teeth as demonstrated by light microscopy. Aust Endod J 32, 35-39.10.1111/j.1747-4477.2006.00006.x ↗
11. 11. Rosenberg SP (2003) The use of erbium, chromium: YSGG laser in microdentistry. Dent Today 22, 70-73.
12. 12. Jou YT, Pertl C (1997) Is there a best retrograde filling material? Dent Clin North Am 41, 555-561.10.1016/S0011-8532(22)00068-4 ↗
13. 13. Gray GJ, Hatton JF, Holtzmann DJ, Jenkins DB, Nielsen CJ (2000) Quality of root-end preparations using ultrasonic and rotary instrumentation in cadavers. J Endod 26, 281-283.10.1097/00004770-200005000-00007 ↗
14. 14. Gondim E Jr, Gomes BP, Ferraz CC, Teixeira FB, Souza-Filho FJ (2002) Effect of sonic and ultrasonic retrograde cavity preparation on the integrity of root apices of freshly extracted human teeth: scanning electron microscopy analysis. J Endod 28, 646-650.10.1097/00004770-200209000-00005 ↗
15. 15. Wright HM Jr, Loushine RJ, Weller RN, Kimbrough WF, Waller J, Pashley DH (2004) Identification of resected root-end dentinal cracks: a comparative study of transillumination and dyes. J Endod 30, 712-715.10.1097/01.DON.0000125876.26495.20 ↗
16. 16. Crang RFE, Klomparens KL (1988) Artifacts in biological electron microscopy. Plenum, New York, 233-309.
17. 10.1016/S0099-2399(99)80382-310.1016/S0099-2399(99)80382-3 ↗
18. 18. Peters CI, Peters OA, Barbakow F (2001) An in vitro study comparing root-end cavities prepared by diamond-coated and stainless steel ultrasonic retrotips. Int Endod J 34,142-148.10.1046/j.1365-2591.2001.00367.x ↗
19. 19. Ishikawa H, Sawada N, Kobayashi C, Suda H (2003) Evaluation of root-end cavity preparation using ultrasonic retrotips. Int Endod J 36, 586-590.10.1046/j.1365-2591.2003.00676.x ↗
20. 20. Lloyd A, Jaunberzins A, Dummer PM, Bryant S (1996) Root-end cavity preparation using the MicroMega Sonic Retro-prep Tip. SEM analysis. Int Endod J 29, 295-301.10.1111/j.1365-2591.1996.tb01388.x ↗
21. 10.2334/josnusd.50.27310.2334/josnusd.50.273 ↗