Effect of modified tray design on accuracy of different impression techniques for parallel and divergent implants
Source abstract
Abstract
This study evaluated the effect of a modified tray design on the accuracy of implant impressions in comparison with the non-splinted and splinted impression techniques. Two titanium frameworks were produced to fit two parallel implants and two divergent implants with a 15o angle. According to the frameworks employed, two acrylic resin master models were fabricated. For each model, 10 impressions were taken with every technique. The maximum framework principal strain was calculated for every generated cast. For the parallel implant model, the strains of the non-splinted (118.4 με), splinted (89.0 με), and modified tray design impression (49.4 με) techniques were statistically similar (P = 0.16). For the divergent implant model, all the impression techniques showed a considerably higher strain than the parallel implant model. The splinted (287.0 με) and the modified (262.9 με) tray design impression techniques showed similar strains for the divergent implant model, which were significantly less than the strains for the non-splinted impression (518.0 με) technique (P < 0.05). Therefore, for two parallel implants, all the impression techniques exhibited similar accuracy. When angulation existed between the implants, the splinted and the modified tray design impression techniques were more accurate than the non-splinted impression technique.
Source: openalex_inverted_index · Quality: baseline
Research context
OpenAlex topics: Dental Implant Techniques and Outcomes · Dental materials and restorations · Bone Tissue Engineering Materials
SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.
Affiliations
Restorative Section, Melbourne Dental School, Melbourne University
References (29)
Show source-provided references
1. 1. Schwarz MS (2000) Mechanical complications of dental implants. Clin Oral Implants Res 11, 156-158.10.1034/j.1600-0501.2000.011S1156.x ↗
2. 2. Abduo J, Judge RB (2014) Implications of implant framework misfit: a systematic review of biomechanical sequelae. Int J Oral Maxillofac Implants 29, 608-621.10.11607/jomi.3418 ↗
3. 3. Lee H, So JS, Hochstedler JL, Ercoli C (2008) The accuracy of implant impressions: a systematic review. J Prosthet Dent 100, 285-291.10.1016/S0022-3913(08)60208-5 ↗
4. 4. Baig MR (2014) Multi-unit implant impression accuracy: a review of the literature. Quintessence Int 45, 39-51.
5. 5. Papaspyridakos P, Chen CJ, Gallucci GO, Doukoudakis A, Weber HP, Chronopoulos V (2014) Accuracy of implant impressions for partially and completely edentulous patients: a systematic review. Int J Oral Maxillofac Implants 29, 836-845.10.11607/jomi.3625 ↗
6. 6. Moreira AH, Rodrigues NF, Pinho AC, Fonseca JC, Vilaca JL (2015) Accuracy comparison of implant impression techniques: a systematic review. Clin Imp Dent Relat Res 17, 751-764.10.1111/cid.12310 ↗
7. 7. Cerqueira NM, Ozcan M, Goncalves M, da Rocha DM, Vasconcellos DK, Bottino MA et al. (2012) A strain gauge analysis of microstrain induced by various splinting methods and acrylic resin types for implant impressions. Int J Oral Maxillofac Implants 27, 341-345.
8. 8. Liu DY, Cader FN, Abduo J, Palamara J (2019) Accuracy of different implant impression techniques: evaluation of new tray design concept. J Prosthodont 28, 682-687.10.1111/jopr.12733 ↗
9. 9. Assuncao WG, Tabata LF, Cardoso A, Rocha EP, Gomes EA (2008) Prosthetic transfer impression accuracy evaluation for osseointegrated implants. Imp Dent 17, 248-256.10.1097/ID.0b013e318182ef58 ↗
10. 10. Chia VA, Esguerra RJ, Teoh KH, Teo JW, Wong KM, Tan KB (2017) In vitro three-dimensional accuracy of digital implant impressions: the effect of implant angulation. Int J Oral Maxillofac Implants 32, 313-321.10.11607/jomi.5087 ↗
11. 11. Elshenawy EA, Alam-Eldein AM, Abd Elfatah FA (2018) Cast accuracy obtained from different impression techniques at different implant angulations (in vitro study). Int J Implant Dent 4, 1-9.10.1186/s40729-018-0118-6 ↗
12. 12. Parameshwari G, Chittaranjan B, Sudhir N, Anulekha-Avinash CK, Taruna M, Ramureddy M (2018) Evaluation of accuracy of various impression techniques and impression materials in recording multiple implants placed unilaterally in a partially edentulous mandible- an in vitro study. J Clin Exp Dent 10, 388-395.10.4317/jced.54726 ↗
13. 13. Inturregui JA, Aquilino SA, Ryther JS, Lund PS (1993) Evaluation of three impression techniques for osseointegrated oral implants. J Prosthet Dent 69, 503-509.10.1016/0022-3913(93)90160-P ↗
14. 14. Choi JH, Lim YJ, Yim SH, Kim CW (2007) Evaluation of the accuracy of implant-level impression techniques for internal-connection implant prostheses in parallel and divergent models. Int J Oral Maxillofac Implants 22, 761-768.
15. 15. Cabral LM, Guedes CG (2007) Comparative analysis of 4 impression techniques for implants. Implant Dent 16, 187-194.10.1097/ID.0b013e3180587b3f ↗
16. 16. Kim S, Nicholls JI, Han CH, Lee KW (2006) Displacement of implant components from impressions to definitive casts. Int J Oral Maxillofac Implants 21, 747-755.
17. 17. Tarib NA, Seong TW, Chuen KM, Kun MS, Ahmad M, Kamarudin KH (2012) Evaluation of splinting implant impression techniques: two dimensional analyses. Eur J Prosthodont Restor Dentistry 20, 35-39.
18. 18. Del Acqua MA, Chavez AM, Castanharo SM, Compagnoni MA, Mollo Fde A Jr (2010) The effect of splint material rigidity in implant impression techniques. Int J Oral Maxillofac Implants 25, 1153-1158.
19. 19. Carr AB (1991) Comparison of impression techniques for a five-implant mandibular model. Int J Oral Maxillofac Implants 6, 448-455.
20. 20. Burns J, Palmer R, Howe L, Wilson R (2003) Accuracy of open tray implant impressions: an in vitro comparison of stock versus custom trays. J Prosthet Dent 89, 250-255.10.1067/mpr.2003.38 ↗
21. 21. Del’acqua MA, de Avila ED, Amaral AL, Pinelli LA, de Assis Mollo F Jr (2012) Comparison of the accuracy of plastic and metal stock trays for implant impressions. Int J Oral Maxillofac Implants 27, 544-550.
22. 22. Gordon GE, Johnson GH, Drennon DG (1990) The effect of tray selection on the accuracy of elastomeric impression materials. J Prosthet Dent 63, 12-15.10.1016/0022-3913(90)90257-D ↗
23. 23. Rueda LJ, Sy-Munoz JT, Naylor WP, Goodacre CJ, Swartz ML (1996) The effect of using custom or stock trays on the accuracy of gypsum casts. Int J Prosthodont 9, 367-373.
24. 24. Millstein P, Maya A, Segura C (1998) Determining the accuracy of stock and custom tray impression/casts. J Oral Rehabil 25, 645-648.10.1046/j.1365-2842.1998.00306.x ↗
25. 25. Ceyhan JA, Johnson GH, Lepe X (2003) The effect of tray selection, viscosity of impression material, and sequence of pour on the accuracy of dies made from dual-arch impressions. J Prosthet Dent 90, 143-149.10.1016/S0022-3913(03)00276-2 ↗
26. 26. de Araujo PA, Jorgensen KD (1985) Effect of material bulk and undercuts on the accuracy of impression materials. J Prosthet Dent 54, 791-794.10.1016/0022-3913(85)90472-X ↗
27. 27. Kumar V, Aeran H (2012) Evaluation of effect of tray space on the accuracy of condensation silicone, addition silicone and polyether impression materials: an in vitro study. J Indian Prosthodont Soc 12, 154-160.10.1007/s13191-012-0124-y ↗
28. 28. Gallucci GO, Papaspyridakos P, Ashy LM, Kim GE, Brady NJ, Weber HP (2011) Clinical accuracy outcomes of closed-tray and open-tray implant impression techniques for partially edentulous patients. Int J Prosthodont 24, 469-472.
29. 29. Perez-Davidi M, Levit M, Walter O, Eilat Y, Rosenfeld P (2016) Clinical accuracy outcomes of splinted and nonsplinted implant impression methods in dental residency settings. Quintessence Int 47, 843-852.