Abstract

A convenient and effective strategy based on the unique characteristics of Azure I/multi-walled carbon nanotube (Azure I/MWNT) composite membranes and the amplification response of enzymes to the antigen−antibody reaction was used to develop a highly sensitive amperometric immunosensor for the detection of α-fetoprotein (AFP). A novel type of Azure I/MWNT composite membrane was fabricated by two steps: first, acid-pretreated MWNT was modified on the surface of glassy carbon electrode. Then, Azure I was coated on MWNT to obtain an Azure I/MWNT composite membrane. Subsequently, gold nanoparticles were adsorbed onto the Azure I/MWNT composite surface by electrostatic interactions between the negatively charged gold nanoparticle and the positively charged Azure I. Later, AFP antibodies were assembled onto the surface of gold nanoparticles. Finally, horseradish peroxidase (HRP) instead of bovine serum albumin was employed to block sites against nonspecific binding and amplified the current signal of the antigen−antibody reaction. Several techniques, including cyclic voltammetry, UV−vis absorption spectroscopy, scanning electron microscopy, transmission electron microscopy, atomic force microscopy, Raman spectroscopy, and X-ray photoelectron spectroscopy, have been employed to characterize the assembly process. Because of the electrocatalytic ability of HRP and MWNT for the reduction of H 2 O 2 and the unique properties of gold nanoparticles, and especially the synergistic augmentation of Azure I and MWNT to facilitate electron-transfer processes, the immunosensor displayed a high sensitivity, fast analytical time, and broader linear response to AFP in two ranges from 0.1 to 8.0 and 8.0 to 250.0 ng/mL with a relatively low detection limit of 0.04 ng/mL at 3 times the background noise. Moreover, the studied immunosensor possessed good reproducibility and storage stability. The proposed methodology was economical, efficient, and potentially attractive for clinical immunoassays.
Source: openalex_inverted_index · Quality: baseline

Research context

OpenAlex topics: Advanced biosensing and bioanalysis techniques · Electrochemical sensors and biosensors · Electrochemical Analysis and Applications

SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.

Affiliations

Chongqing Key Laboratory of Analytical Chemistry, College of Chemistry and Chemical Engineering, Southwest University, Chongqing 400715, China

References (45)

Show source-provided references
1. Wilson G. S. · Chem. Rev. · 2000 · 100 · 70410.1021/cr990003y ↗
2. Warsinke A. · Fresen. J. Anal. Chem. · 2000 · 366 · 63410.1007/s002160051557 ↗
3. Van Emon J. M. · Anal. Chem. · 1992 · 64 · 8910.1021/ac00026a001 ↗
4. Bilitewski U. · Anal. Chem. · 2000 · 72 · 70110.1021/ac002953l ↗
5. Gillespie J. R. · Biochim. Biophys. Acta · 2000 · 1480 · 5610.1016/S0167-4838(00)00104-7 ↗
6. Li T. · 2001 · 169
7. Matsuya T. · Anal. Chem. · 2003 · 75 · 613210.1021/ac034346e ↗
8. Wang G. L. · Anal. Chim. Acta · 2001 · 448 · 172
9. Belanger L. · Clin. Chim. Acta · 1973 · 48 · 1810.1016/0009-8981(73)90211-8 ↗
10. Aguilar Z. P. · Anal. Chem. · 2002 · 74 · 332910.1021/ac0110348 ↗
11. Xu Y. Y. · Anal. Chim. Acta · 2006 · 561 · 54
12. Fu Z. F. · J. Immunol. Methods · 2006 · 312 · 67
13. Chen J. · Biomaterials · 2006 · 27 · 2321
14. Wang Z. J. · Talanta · 2006 · 69 · 690
15. Liu Y. · J. Biosens. Bioelectron. · 2005 · 21 · 988
16. Yang L. · Talanta · 2005 · 68 · 4610.1016/j.talanta.2005.04.038 ↗
17. Wang J. · Biosens. Bioelectron. · 2006 · 21 · 1892
18. Baughman R. H. · Science · 2002 · 297 · 79210.1126/science.1060928 ↗
19. Wang J. · Anal. Chem. · 2003 · 75 · 2079
20. Lei Q. · Talanta · 2006 · 68 · 727
21. Moore R. R. · Anal. Chem. · 2004 · 76 · 2682
22. Wang J. · J. Am. Chem. Soc. · 2003 · 125 · 2409
23. Musameh M. · Electrochem. Commun. · 2002 · 4 · 74610.1016/S1388-2481(02)00451-4 ↗
24. Zhang P. · Bioelectrochemistry · 2005 · 67 · 114
25. Chen R. J. · J. Am. Chem. Soc. · 2001 · 123 · 3839
26. Xu J. Z. · Electroanalysis · 2003 · 15 · 224
27. Li Q. W. · Carbon · 2004 · 42 · 291
28. Zeng J. X. · J. Electroanal. Chem. · 2006 · 595 · 160
29. Zhang M. G. · J. Am. Chem. Soc. · 2005 · 127 · 2059
30. Cai C. X. · J. Electroanal. Chem. · 1997 · 427 · 153
31. Lawrence N. S. · Electrochem. Commun. · 2006 · 8 · 7610.1016/j.elecom.2005.10.026 ↗
32. Zhao S. · Bioelectrochemistry · 2006 · 69 · 163
33. Zhuo Y. · Anal. Chim. Acta · 2005 · 548 · 21010.1016/j.aca.2005.05.058 ↗
34. Zhuo Y. · Sens. Actuators, B · 2006 · 114 · 63910.1016/j.snb.2005.04.051 ↗
35. Guo M. L. · Electrochim. Acta · 2004 · 49 · 2643
36. Enustun B. V. · J. Am. Chem. Soc. · 1963 · 85 · 332810.1021/ja00904a001 ↗
37. Zhang M. N. · Langmuir · 2004 · 20 · 8785
38. Zhao L. Y. · J. Colloid Interface Sci. · 2006 · 296 · 211
39. Chambers G. · J. Nano Lett. · 2003 · 3 · 84610.1021/nl034181p ↗
40. Hu C. G. · Carbon · 2006 · 44 · 434
41. Kuan H. C. · Compos. Sci. Technol. · 2005 · 65 · 1710
42. Zhang M. N. · Biosens. Bioelectron. · 2005 · 20 · 127610.1016/j.bios.2004.04.018 ↗
43. Tsai Y. C. · Langmuir · 2005 · 21 · 3658
44. Li X. L. · J. Biotechnol. · 2006 · 123 · 366
45. Bond A. M. · 1980