Comment on “Excited-State Intermolecular Proton Transfer of Lumazine”
Source abstract
Abstract
A critical comment on excited-state intermolar proton transfer of lumazine was discussed. In their article, Hupper and co-researchers reported the emission properties of lumazine (Lum) using steady-state and time-resolved emission techniques. They also reported the absorption spectra at different pH and they evaluated the pKa value in water to be about 10.5. Hupper do not mention how the pH was measured. The critic´s results on emission of Lum indicate that the fluorescence of Lum is quenched by hydroxide anions, and consequently, a decrease of the fluorescence is observed at pH higher than 10.5. Hupper and co-researchers did not refer the tautomerism of Lum, which implies different atoms participating in proton transfer they also postulate. Indeed, they discuss the inter-molecular proton transfer in the excited state of Lum, but they analyzed the tautomeric forms of Lum neither in the ground state nor in the excited state.
Source: openalex_inverted_index · Quality: baseline
Research context
OpenAlex topics: Photochemistry and Electron Transfer Studies · Porphyrin and Phthalocyanine Chemistry · Spectroscopy and Quantum Chemical Studies
SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.
Affiliations
Instituto de Investigaciones Fisicoquímicas Teóricas y Aplicadas (INIFTA), Facultad de Ciencias Exactas, Universidad Nacional de La Plata, CCT La Plata-CONICET, Casilla de Correo 16, Sucursal 4, (1900) La Plata, Argentina; Engler-Bunte Institut, Karlsruhe Institute of Technology, D-76128 Karlsruhe, Germany, and Laboratoire des IMRCP, UMR CNRS 5623, Université Paul Sabatier (Toulouse III), 118 route de Narbonne, F-31062 Toulouse cédex 9, France
References (8)
Show source-provided references
1. Presiado I. · J. Phys. Chem. C · 2010 · 114 · 363410.1021/jp907141b ↗
2. Albert A. · J. Chem. Soc. · 1951 · 47410.1039/jr9510000474 ↗
3. Lippert E. · Z. Elektrochem. · 1960 · 64 · 662
4. Pfleiderer W. I. · Chem. Ber. · 1957 · 90 · 258210.1002/cber.19570901125 ↗
5. Spectrophotometric titration; pH of the aqueous solutions was adjusted by adding drops of HCl or NaOH from a micropipette. The concentrations of the acid and base used for this purpose ranged from 0.1 to 2 M. The pH measurements were performed with a pH-meter PHM220 (Radiometer Copenhagen) and a combined pH electrode pHC2011-8 (Radiometer Analytical).
6. Tatischeff I. · Hoppe-Seyler’s Physiol. Chem. · 1984 · 365 · 125510.1515/bchm2.1984.365.2.1255 ↗
7. Steady-state fluorescence measurements were performed on air-equilibrated aqueous solutions using an Edinburgh EAI-FS/FL900 SPC equipment. The quartz cells (1 cm path length) used for the measurements were thermoregulated at 24.0 ± 0.2 °C. Corrected fluorescence spectra obtained by excitation at 350 nm (high pressure Xe lamp, 419 W) were recorded between 360 and 650 nm.
8. Klein R. · Photochem. Photobiol. · 1987 · 45 · 5510.1111/j.1751-1097.1987.tb08405.x ↗