Controlling Nanodrop Passage through Capillary Nanovalves by Adjusting Lyophilic Crevice Structure
Source abstract
Abstract
The passage or blockage of nanodrops through a nanovalve made of a nanocrevice is explored by proof-of-concept simulations, including many-body dissipative particle dynamics and Surface Evolver simulations. Although it is generally believed that the drops wet lyophilic crevices readily, we show that the penetration of the drops into such crevices with specific structures can be prevented. The morphological phase diagram in terms of the contact angle (θ Y ) and wedge angle (α) are constructed, and three regimes are identified: non-penetration and partial penetration, in addition to complete penetration. It is interesting to find that as long as α is small enough, the drop always runs away from the crevice even on lyophilic surfaces, leading to the non-penetration state. For intermediate α and small θ Y, the drop tends to break up, and only a portion of liquid wets the crevice, corresponding to the partial penetration state. Our simulation results demonstrate that a lyophilic capillary nanovalve for controlling the droplet passage can be fabricated by simply adjusting the wedge angle of the crevice.
Source: openalex_inverted_index · Quality: baseline
Research context
OpenAlex topics: Pickering emulsions and particle stabilization · Surface Modification and Superhydrophobicity · Block Copolymer Self-Assembly
SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.
Affiliations
Department of Chemical Engineering, National Taiwan University, Taipei, Taiwan 10617
Funding
Ministry of Science and Technology, Taiwan
References (33)
Show source-provided references
1. 10.1146/annurev.fluid.36.050802.12212410.1146/annurev.fluid.36.050802.122124 ↗
2. 10.1038/nmat322810.1038/nmat3228 ↗
3. 10.1038/nmat85610.1038/nmat856 ↗
4. De Gennes P. G. · 200410.1007/978-0-387-21656-0 ↗
5. 10.1021/ie50320a02410.1021/ie50320a024 ↗
6. 10.1039/tf944400054610.1039/tf9444000546 ↗
7. 10.1063/1.280442510.1063/1.2804425 ↗
8. 10.1126/science.125478710.1126/science.1254787 ↗
9. 10.1039/C7CP01409K10.1039/C7CP01409K ↗
10. Man, P. F.; Mastrangelo, C. H.; Burns, M. A.; Burke, D. T.Microfabricated capillary-driven stop valve and sample injector. InProceedings, IEEE Conference MEMS;IEEE:Heidelberg, Germany, 1998, 45–50.10.1109/MEMSYS.1998.659727 ↗
11. Allain, M.; Berthier, J.; Basrour, S.; Pouteau, P.Sacrificial membranes for serial valving in microsystems.Nanotech Conference;NSTI:Houston, TX, 2009, 3, 343–346.10.1088/0960-1317/20/3/035006 ↗
12. Koch, M.; Evans, A.; Brunnschweiler, A.Microfluidic Technology and Applications;Baldock Research Studies Press:Hertfordshire, U.K., 2000, 3–16.
13. Esfandyarpour, H.; Davis, R. W.Microfluidic valve-controllable magnetic bead receptacle: a novel platform for DNA sequencing.Nanotech Conference;NSTI:Santa Clara, CA, 2007, 3, 421–424.
14. Berthier J. · 201210.1002/9781118401323 ↗
15. 10.1021/la402660210.1021/la4026602 ↗
16. 10.1002/adma.20060277410.1002/adma.200602774 ↗
17. Chang, K. F.; Tsai, Y. C.; Shih, W. P.; Yang, L. J.An electro-active nano-valve array for reusable drug delivery system. InProceedings, IEEE Conference MEMS;IEEE:Hong Kong, China, 2010, 1039–1042.10.1109/MEMSYS.2010.5442387 ↗
18. 10.1039/b821803j10.1039/b821803j ↗
19. 10.1016/S0925-4005(00)00396-810.1016/S0925-4005(00)00396-8 ↗
20. 10.1016/j.jcp.2006.07.01710.1016/j.jcp.2006.07.017 ↗
21. 10.1103/PhysRevE.82.01670610.1103/PhysRevE.82.016706 ↗
22. 10.1021/la204207s10.1021/la204207s ↗
23. 10.1063/1.359037610.1063/1.3590376 ↗
24. 10.1140/epje/i2013-13010-710.1140/epje/i2013-13010-7 ↗
25. 10.1103/PhysRevE.68.06670210.1103/PhysRevE.68.066702 ↗
26. 10.1103/PhysRevE.94.04280710.1103/PhysRevE.94.042807 ↗
27. 10.1063/1.496543210.1063/1.4965432 ↗
28. 10.1039/C7CP04979J10.1039/C7CP04979J ↗
29. 10.1063/1.174778210.1063/1.1747782 ↗
30. 10.1103/PhysRevE.82.01670610.1103/PhysRevE.82.016706 ↗
31. 10.1039/C5CS00736D10.1039/C5CS00736D ↗
32. 10.1080/10586458.1992.1050425310.1080/10586458.1992.10504253 ↗
33. 10.1098/rsta.1996.009510.1098/rsta.1996.0095 ↗