journal article·2013-01-03Open access

Tuning Fluorescence Direction with Plasmonic Metal–Dielectric–Metal Substrates

Sharmistha Dutta Choudhury, Ramachandram Badugu, Kazimierz Nowaczyk, Krishanu Ray, Joseph R. Lakowicz

Abstract

Controlling the emission properties of fluorophores is essential for improving the performance of fluorescence-based techniques in modern biochemical research, medical diagnosis, and sensing. Fluorescence emission is isotropic in nature, which makes it difficult to capture more than a small fraction of the total emission. Metal- dielectric-metal (MDM) substrates, discussed in this Letter, convert isotropic fluorescence into beaming emission normal to the substrate. This improves fluorescence collection efficiency and also opens up new avenues for a wide range of fluorescence-based applications. We suggest that MDM substrates can be readily adapted for multiple uses, such as in microarray formats, for directional fluorescence studies of multiple probes or for molecule-specific sensing with a high degree of spatial control over the fluorescence emission. SECTION: Physical Processes in Nanomaterials and Nanostructures.
Source: openalex_inverted_index · Quality: baseline

Research context

OpenAlex topics: Gold and Silver Nanoparticles Synthesis and Applications · Plasmonic and Surface Plasmon Research · Advanced Biosensing Techniques and Applications

SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.

Affiliations

Center for Fluorescence Spectroscopy, Department of Biochemistry and Molecular Biology, University of Maryland School of Medicine, 725 West Lombard Street, Baltimore, Maryland 21201, United States

References (22)

Show source-provided references
1. Gryczynski I. · Anal. Biochem. · 2004 · 324 · 17010.1016/j.ab.2003.09.036 ↗
2. Gryczynski I. · J. Phys. Chem. B · 2004 · 108 · 1207310.1021/jp0312619 ↗
3. Jun Y. C. · Nat. Commun. · 2011 · 283 · 1
4. Aouani H. · Nano Lett. · 2011 · 11 · 240010.1021/nl200772d ↗
5. Schuller J. A. · Nat. Mater. · 2010 · 9 · 19310.1038/nmat2630 ↗
6. Lal S. · Nat. Photonics · 2007 · 1 · 64110.1038/nphoton.2007.223 ↗
7. Barnes W. L. · Nature · 2003 · 424 · 82410.1038/nature01937 ↗
8. Curto A. G. · Science · 2010 · 329 · 93010.1126/science.1191922 ↗
9. Yuk J. S. · Anal. Bioanal. Chem. · 2010 · 398 · 194710.1007/s00216-010-4026-8 ↗
10. Xie T.-T. · Chem. Commun. · 2009 · 319010.1039/b823352g ↗
11. Chandran A. · Phys. Rev. B · 2012 · 85 · 08541610.1103/PhysRevB.85.085416 ↗
12. Diest K. · Nano Lett. · 2009 · 9 · 257910.1021/nl900755b ↗
13. Dionne J. A. · Nano Lett. · 2006 · 6 · 192810.1021/nl0610477 ↗
14. Enderlein J. · Opt. Express · 2005 · 13 · 885510.1364/OPEX.13.008855 ↗
15. Calander N. · J. Phys. Chem. B · 2005 · 109 · 1395710.1021/jp0510544 ↗
16. Becker H. · J. Appl. Phys. · 1997 · 81 · 282510.1063/1.363940 ↗
17. Becker H. · Appl. Phys. Lett. · 1998 · 72 · 126610.1063/1.121045 ↗
18. Purcell E. M. · Phys. Rev. · 1946 · 69 · 68110.1103/PhysRev.69.37 ↗
19. Worthing P. T. · J. Opt. A: Pure Appl. Opt. · 1999 · 1 · 50110.1088/1464-4258/1/4/315 ↗
20. Nagl S. · Microchim. Acta · 2005 · 151 · 110.1007/s00604-005-0393-9 ↗
21. Andrew P. · Science · 2004 · 306 · 100210.1126/science.1102992 ↗
22. Collini E. · J. Am. Chem. Soc. · 2012 · 134 · 1006110.1021/ja3014314 ↗