An experimental study on thermal runaway characteristics of lithium-ion batteries with high specific energy and prediction of heat release rate
Source abstract
Abstract
Understanding the potential thermal hazards of lithium-ion batteries (LIBs) during thermal runaway (TR) is helpful to assess the safety of LIB during storage, transport and use. This paper presents a comprehensive analysis of the thermal runaway (TR) characteristics of type 21700 cylindrical LIBs with a specific energy of 266 W∙h/kg. The batteries with both 30% state of charge (SOC) and 100% SOC were triggered to TR by uniform heating using a flexible heater in a laboratory environment. Three high definition cameras and one high-speed camera were placed to capture TR behavior and flame evolution from different viewpoints. Correlation between the heat release rate (HRR) and the mean flame height of turbulent jet diffusion flame were used to estimate the HRRs of LIBs. Additional characteristics of cell failure (for cells with 100% and 30% SOC) were also noted for comparison, including: number of objects ejected from the cell; sparks and subsequent jet fires. An approach has been developed to estimate the HRRs from TR triggered fires and results compared with previous HRR measurements for type 18650 cylindrical cells with a similar cathode composition.
Source: openalex_inverted_index · Quality: baseline
Research context
OpenAlex topics: Advanced Battery Technologies Research · Risk and Safety Analysis · Combustion and Detonation Processes
SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.
References (38)
Show source-provided references
1. Thermal runaway caused fire and explosion of lithium ion battery10.1016/j.jpowsour.2012.02.038 ↗
2. Thermal runaway mechanism of lithium ion battery for electric vehicles: a review10.1016/j.ensm.2017.05.013 ↗
3. A review of lithium ion battery failure mechanisms and fire prevention strategies10.1016/j.pecs.2019.03.002 ↗
4. Investigation on the thermal hazards of 18650 lithium ion batteries by fire calorimeter10.1007/s10973-015-4751-5 ↗
5. An experimental study on burning behaviors of 18650 lithium ion batteries using a cone calorimeter10.1016/j.jpowsour.2014.09.039 ↗
6. The combustion behavior of large scale lithium titanate battery10.1038/srep07788 ↗
7. Heat release during thermally-induced failure of a lithium ion battery: impact of cathode composition10.1016/j.firesaf.2016.08.001 ↗
8. Characterization of behaviour and hazards of fire and deflagration for high-energy Li-ion cells by over-heating10.1016/j.jpowsour.2018.07.044 ↗
9. Study of the fire behavior of high-energy lithium-ion batteries with full-scale burning test10.1016/j.jpowsour.2015.03.035 ↗
10. Measuring the energetics of a lithium ion battery in thermal runaway
11. Investigation on the fire-induced hazards of Li-ion battery cells by fire calorimetry10.1039/C1EE02218K ↗
12. Combustion behavior of lithium iron phosphate battery induced by external heat radiation10.1016/j.jlp.2016.12.002 ↗
13. Thermal runaway and fire behaviors of large-scale lithium ion batteries with different heating methods10.1016/j.jhazmat.2019.06.007 ↗
14. Thermal runaway and fire behavior investigation of lithium ion batteries using modified cone calorimeter10.1007/s10973-018-7599-7 ↗
15. Effects of heat treatment and SOC on fire behaviors of lithium-ion batteries pack10.1007/s10973-018-7864-9 ↗
16. Fire behaviors study on 18650 batteries pack using a cone-calorimeter10.1007/s10973-018-7891-6 ↗
17. Fire behavior of lithium-ion battery with different states of charge induced by high incident heat fluxes10.1007/s10973-018-7899-y ↗
18. Study of the temperature and flame characteristics of two capacity LiFePO4 batteries in thermal runaway10.1149/2.0531816jes ↗
19. Experimental investigation of cascading failure in 18650 lithium ion cell arrays: impact of cathode chemistry10.1016/j.jpowsour.2019.227347 ↗
20. Scenario-based prediction of Li-ion batteries fire-induced toxicity10.1016/j.jpowsour.2016.02.090 ↗
21. In-depth safety-focused analysis of solvents used in electrolytes for large scale lithium ion batteries10.1039/c3cp51315g ↗
22. Energy density of cylindrical Li-ion cells: a comparison of commercial 18650 to the 21700 cells10.1149/2.0281814jes ↗
23. Maloney · 2016
24. Explosion hazards from lithium-ion battery vent gas10.1016/j.jpowsour.2019.227257 ↗
25. Bergström · 2015
26. Pyrotechnic spark generation
27. A review of the features and analyses of the solid electrolyte interphase in Li-ion batteries10.1016/j.electacta.2010.05.072 ↗
28. Transition from momentum to buoyancy-controlled turbulent jet diffusion flames and flame height relationships10.1016/0010-2180(93)90148-V ↗
29. Quantification of combustion hazards of thermal runaway failures in lithium-ion batteries10.4271/2014-01-1857 ↗
30. Thermal runaway of commercial 18650 Li-ion batteries with LFP and NCA cathodes–impact of state of charge and overcharge10.1039/C5RA05897J ↗
31. Flammability characteristics of the battery vent gas: a case of NCA and LFP lithium-ion batteries during external heating abuse10.1016/j.est.2019.100775 ↗
32. Hazard analysis of thermally abused lithium-ion batteries at different state of charges10.1016/j.est.2019.101065 ↗
33. Turbulent jet diffusion flames: consolidation of flame height data10.1016/S0010-2180(98)00161-8 ↗
34. Modeling vaporization, gas generation and venting in Li-ion battery cells with a dimethyl carbonate electrolyte10.1149/2.0631709jes ↗
35. Thermal-runaway experiments on consumer Li-ion batteries with metal-oxide and olivin-type cathodes10.1039/C3RA45748F ↗
36. Ottaway
37. Experimental analysis of thermal runaway in 18650 cylindrical Li-ion cells using an accelerating rate calorimeter10.3390/batteries3020014 ↗
38. Mier · 2018