journal article·2018-03Open access

Power ramp rate capabilities of a 5 kW proton exchange membrane fuel cell system with discrete ejector control

K. Nikiforow, J. Pennanen, J. Ihonen, S. Uski, P. Koski

Abstract

The power ramp rate capabilities of a 5 kW proton exchange membrane fuel cell (PEMFC) system are studied theoretically and experimentally for grid support service applications. The fuel supply is implemented with a fixed-geometry ejector and a discrete control solution without any anode-side pressure fluctuation suppression methods. We show that the stack power can be ramped up from 2.0 kW to 4.0 kW with adequate fuel supply and low anode pressure fluctuations within only 0.1 s. The air supply is implemented with a centrifugal blower. Air supply ramp rates are studied with a power increase executed within 1 and 0.2 s after the request, the time dictated by grid support service requirements in Finland and the UK. We show that a power ramp-up from 2.0 kW to 3.7 kW is achieved within 1 s with an initial air stoichiometry of 2.5 and within 0.2 s with an initial air stoichiometry of 7.0. We also show that the timing of the power ramp-up affects the achieved ancillary power capacity. This work demonstrates that hydrogen fueled and ejector-based PEMFC systems can provide a significant amount of power in less than 1 s and provide valuable ancillary power capacity for grid support services.
Source: openalex_inverted_index · Quality: baseline

Research context

OpenAlex topics: Fuel Cells and Related Materials · Advanced battery technologies research · Electrocatalysts for Energy Conversion

SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.

References (25)

Show source-provided references
1. The relevance of inertia in power systems10.1016/j.rser.2015.11.016 ↗
2. Nordic TSOs
3. Commission regulation (EU) 2016/631
4. ENTSO-E · 2017
5. ENTSO-E
6. National Grid · 2016
7. AEMC
8. Proposed future ancillary services in electric reliability Council of Texas
9. Ihonen
10. Operational experiences of PEMFC pilot plant using low grade hydrogen from sodium chlorate production process10.1016/j.ijhydene.2017.09.056 ↗
11. Experimental analysis of a 20 kWe PEM fuel cell system in dynamic conditions representative of automotive applications10.1016/j.enconman.2008.04.001 ↗
12. Dynamic behaviour of hydrogen fuel cells for automotive application10.1016/j.renene.2008.12.021 ↗
13. Model-based control of cathode pressure and oxygen excess ratio of a PEM fuel cell system10.1016/j.jpowsour.2007.08.049 ↗
14. Robust control of the PEM fuel cell air-feed system via sub-optimal second order sliding mode10.1016/j.apenergy.2012.12.012 ↗
15. Discrete ejector control solution design, characterization, and verification in a 5 kW PEMFC system10.1016/j.ijhydene.2017.05.151 ↗
16. Improved PEM fuel cell system operation with cascaded stack and ejector-based recirculation10.1016/j.apenergy.2017.03.002 ↗
17. Hydrogen purge and reactant feeding strategies in self-humidified PEM fuel cell systems10.1016/j.ijhydene.2016.06.196 ↗
18. AutoStack – core – Industry led European consortium to develop next generation automotive stack hardware
19. Two-phase flow and thermal transients in proton exchange membrane fuel cells - a critical review10.1016/j.ijhydene.2015.01.126 ↗
20. Main factors affecting the lifetime of Proton Exchange Membrane fuel cells in vehicle applications: a review10.1016/j.apenergy.2014.03.048 ↗
21. Impact of flow rates and electrode specifications on degradations during repeated startups and shutdowns in polymer-electrolyte membrane fuel cells10.1016/j.jpowsour.2013.10.141 ↗
22. Scientific aspects of polymer electrolyte fuel cell durability and degradation10.1021/cr050182l ↗
23. Designing a hydrogen gas ejector for 5 kW stationary PEMFC system – CFD-modeling and experimental validation10.1016/j.ijhydene.2016.06.122 ↗
24. PowerCell Ab, PowerCell S2 Datasheet, n.d. http://www.powercell.se/wp-content/uploads/2017/05/S2-Data-Sheet.pdf (Accessed 28 August 2017).
25. Investigation of degradation effects in polymer electrolyte fuel cells under automotive-related operating conditions10.1016/j.jpowsour.2014.10.127 ↗